• Title/Summary/Keyword: Model Material Test

Search Result 1,450, Processing Time 0.034 seconds

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

Cardioprotective Effect by Preconditioning with Calcium-free Solution (칼슘결핍용액 투여 전처치에 의한 심근보호 효과)

  • 조대윤;이종화;김호덕
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.773-780
    • /
    • 1999
  • Background: It has been demonstrated that brief periods of calcium depletion and repletion (calcium-free preconditioning, CP) have cardioprotective effects as seen in ischemic preconditioning(IP) which enhances the recovery of post-ischemic contractile dysfunction and reduces the incidence of reperfusion-induced arrhythmia or infarct size after a prolonged ischemia. In the present study, we tested this paradoxical phenomenon in isolated rabbit hearts. Material and Method: Hearts isolated from New Zealand white rabbits(1.5∼2.0 Kg body weight) were perfused with Tyrode solution using the Langendorff technique. After stabilizing the baseline hemodynamics, the hearts were subjected to 45 minutes of global ischemia followed by 120 minutes of reperfusion with IP(IP group, n=7) or without IP (ischemic control group, n=7). IP was induced by a single episode of 5 minutes global ischemia and 10 minutes reperfusion. In the CP group(n=7), the hearts were subjected to perfusion with Tyrode solution with calcium depletion for 5 minutes and repletion for 10 minutes, and 45 minutes of ischemia and 120 minutes of reperfusion. Left ventricular function including developed pressure, dP/dt, heart rate, left ventricular end-diastolic pressure and coronary flow was measured. Infarct size was determined by staining with 1% triphenyltetrazolium chloride and planimetry. Data were analyzed by a one-way analysis of variance and Tukey's post-hoc test. Result: In comparison with the ischemic control group, IP significantly enhanced the recovery of the left ventricular function including the left ventricular developed pressure, contractility, and coronary flow; in contrast, these functional parameters of the CP group tended to be lower than those of the ischemic control group. However, the infarct size was significantly reduced by IP or CP(p<0.05). Conclusion: These results suggest that in isolated Langendorff-perfused rabbit heart model, CP(induced by single episode of 5 minutes calcium depletion and 10 minutes repletion) could not improve the post-ischemic contractile dysfunction(after a 45-minute global ischemia) but it has an infarct size-limiting effect.

  • PDF

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Tumorigenesis after Injection of Lung Cancer Cell Line (SW-900 G IV) into the Pleural Cavity of Nude Mice (누드마우스의 흉강에 폐암세포주의 주입에 의한 종양형성과 HER2/neu와 TGF-${\beta}_1$의 발현)

  • Park, Eok-Sung;Kim, Song-Myung;Kim, Jong-In
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.588-595
    • /
    • 2010
  • Background: Base on types of tumor, the types of expressed tumor is diverse and the difference in its expression rate is even more various. Due to such reasons an animal model is absolutely needed for a clinical research of lung cancer. The author attempted oncogenesis by cultivating a cell line of non-small cell carcinoma and then injecting it inside thoracic cavities of nude mice. The author conducted quantitative analyses of HER2/neu tumor gene - an epidermal growth factor receptor (EGFR) related to lung cancer, and TGF-${\beta}_1$, which acts as a resistance to cell growth inhibition and malignant degeneration. In order to investigate achievability of the oncogenesis, histological changes and the expression of cancer gene in case of orthotopic lung cancer is necessary. Material and Method: Among 20 immunity-free male BALB/c, five nude mice were selected as the control group and rest as the experimental group. Their weights ranged from 20 to 25 gm (Orient, Japan). After injection of lung cancer line (SW900 G IV) into the pleural cavity of nude mice, They were raised at aseptic room for 8 weeks. HER2/neu was quantitatively analyzed by separating serum from gathered blood via chemiluminiscent immunoassay (CLIA), and immunosandwitch method was applied to quantitatively analyze TGF-${\beta}_1$. SPSS statistical program (SPSS Version 10.0, USA) was implemented for statistical analysis. Student T test was done, and cases in which p-value is less than 0.05 were considered significant. Result: Even after lung cancer was formed in the normal control group or after intentionally injected lung cancer cell line, no amplification of HER2/neu gene showed reaction. However, the exact quantity of TGF-${\beta}_1$ was $28,490{\pm}8,549pg/mL$, and the quantity in the group injected with lung cancer cell was $42,362{\pm}14,449pg/mL$, meaning 1.48 times highly Significant (p<0.483). It proved that HER2/neu gene TGF-${\beta}_1$ had no meaningful interconnection. Conclusion: TGF-${\beta}_1$ gene expressed approximately 1.48 times amplification in comparison to the control group. The amplification of TGF-${\beta}_1$ meant somatic recuperation inhibition mechanism due to carcinogenesis in nude mice was definitely working. It may be implemented as a quantitative analysis that allows early detection of lung cancer in human body.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

The Effect of Franchisor's On-going Support Services on Franchisee's Relationship Quality and Business Performance in the Foodservice Industry (외식 프랜차이즈 가맹본부의 사후 지원서비스가 가맹점의 관계품질과 경영성과에 미치는 영향)

  • Lee, Jae-Han;Lee, Yong-Ki;Han, Kyu-Chul
    • Journal of Distribution Research
    • /
    • v.15 no.3
    • /
    • pp.1-34
    • /
    • 2010
  • Introduction The purpose of this research is to develop overall model which involves the effect of ongoing support services by franchisor on franchisee's relationship quality(trust, satisfaction, and commitment) and business performance(financial and non-financial performance), and to investigate the relationships among trust, satisfaction, commitment, financial and non-financial performance. This study also suggests franchise business or franchise system should be based on long-term orientation between franchisor and franchisee rather than short-term orientation, or transactional relationship, and proposes the most effective way of providing on-going support services by franchisor with franchisee thru symbiotic relationship among franchisor and franchisee Research Model and Hypothesis The research model as Figure 1 shows the variables on-going support services which affect the relationship quality between franchisor and franchisee such as trust, satisfaction, and commitment, and also analyze the effects of relationship quality on business performance including financial and non-financial performance We established 12 hypotheses to test as follows; Relationship between on-going support services and trust H1: On-going support services factors (product category & price, logistics service, promotion, information providing & problem solving capability, supervisor's support, and education & training support) have positive effect on franchisee's trust. Relationship between on-going support services and satisfaction H2: On-going support services factors (product category & price, logistics service, promotion, information providing & problem solving capability, supervisor's support, and education & training support) have positive effect on franchisee's satisfaction. Relationship between on-going support services and commitment H3: On-going support services factors (product category & price, logistics service, promotion, information providing & problem solving capability, supervisor's support, and education & training support) have positive effect on franchisee's commitment. Relationship among relationship quality: trust, satisfaction, and commitment H4: Franchisee's trust has positive effect on franchisee's satisfaction. H5: Franchisee's trust has positive effect on franchisee's commitment. H6: Franchisee's satisfaction has positive effect on franchisee's commitment. Relationship between relationship quality and business performance H7: Franchisee's trust has positive effect on franchisee's financial performance. H8: Franchisee's trust has positive effect on franchisee's non-financial performance. H9: Franchisee's satisfaction has positive effect on franchisee's financial performance. H10: Franchisee's satisfaction has positive effect on franchisee's non-financial performance. H11: Franchisee's commitment has positive effect on franchisee's financial performance. H12: Franchisee's commitment has positive effect on franchisee's non-financial performance. Method The on-going support services were defined as an organized system of continuous supporting services by franchisor for the purpose of satisfying the expectation of franchisee based on long-term orientation and classified into six constructs such as product category & price, logistics service, promotion, providing information & problem solving capability, supervisor's support, and education & training support. The six constructs were measured agreement using a 7-point Likert-type scale (1 = strongly disagree to 7 = strongly agree)as follows. The product category & price was measured by four items: menu variety, price of food material provided by franchisor, and support for developing new menu. The logistics service was measured by six items: distribution system of franchisor, return policy for provided food materials, timeliness, inventory control level of franchisor, accuracy of order, and flexibility of emergency order. The promotion was measured by five items: differentiated promotion activities, brand image of franchisor, promotion effect such as customer increase, long-term plan of promotion, and micro-marketing concept in promotion. The providing information & problem solving capability was measured by information providing of new products, information of competitors, information of cost reduction, and efforts for solving problems in franchisee's operations. The supervisor's support was measured by supervisor operations, frequency of visiting franchisee, support by data analysis, processing the suggestions by franchisee, diagnosis and solutions for the franchisee's operations, and support for increasing sales in franchisee. Finally, the of education & training support was measured by recipe training by specialist, service training for store people, systemized training program, and tax & human resources support services. Analysis and results The data were analyzed using Amos. Figure 2 and Table 1 present the result of the structural equation model. Implications The results of this research are as follows: Firstly, the factors of product category, information providing and problem solving capacity influence only franchisee's satisfaction and commitment. Secondly, logistic services and supervising factors influence only trust and satisfaction. Thirdly, continuing education and training factors influence only franchisee's trust and commitment. Fourthly, sales promotion factor influences all the relationship quality representing trust, satisfaction, and commitment. Fifthly, regarding relationship among relationship quality, trust positively influences satisfaction, however, does not directly influence commitment, but satisfaction positively affects commitment. Therefore, satisfaction plays a mediating role between trust and commitment. Sixthly, trust positively influence only financial performance, and satisfaction and commitment influence positively both financial and non-financial performance.

  • PDF

Experimental Study on the Effect of Filter Layers on Pumping Capacity and Well Efficiency in an Unconfined Aquifer (자유면대수층에서 필터층이 취수량 및 우물효율에 미치는 영향에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.405-416
    • /
    • 2017
  • This study evaluated a model unconfined aquifer comprising a sand or gravel layer, a filter layer, a pumping well, and an observation well. The model was employed in step drawdown tests and then used to assess the permeability of each test tank. The optimal yield and well efficiency were then calculated. Evaluation of yield by step in sand layer filters of equal thickness gave optimized watering rates of 22.03 L/min in the double filter and 19.71 L/min in the single filter. The double filter's yield was 115.0% that of the single filter. A comparison of double and single filters, each 10 cm thick, showed the double filter to have a maximum yield of 182.7%. Yields for the gravel layer were 73.56 L/min for a double filter and 65.47 L/min for a single filter of the same thickness; the former value is 112.3% of that of the latter. Comparison of double and single filters with 10-cm-thick gravel layers revealed that the double filter had a maximum yield of 160.9%. Results for sand wells showed the double filter to have a maximum efficiency of 70.4% and the single filter to have a minimum efficiency of 37.1%. Gravel-layer well efficiencies were >66.5% for both double and single filters (each 30 cm thick), but only 22.5% for a 10-cm-thick single filter. This study confirms that permeability improved as the filter material became thicker; it also shows that a double filter has a higher yield and well efficiency than a single filter. These results can be applied to the practical design of wells.

Development of 'the safety' theme-based integrated teaching·learning process plans for the middle school Home Economics Instruction (중학교 가정과 수업을 위한 '안전' 주제 중심 통합 교수·학습 과정안 개발)

  • Kim, Nam Eun;Chae, Jung Hyun;Cho, Jae Soon
    • Journal of Korean Home Economics Education Association
    • /
    • v.28 no.1
    • /
    • pp.19-39
    • /
    • 2016
  • The purpose of this study was to develop the safety theme-based integrated teaching learning process plans for the middle school Home Economics(HE) Instruction and ultimately to contribute for the middle school students to live their safe lives. To achieve the goals of this study, HE curriculum documents from the 1st to the 2015 revision were analyzed and a survey was conducted to identify the middle school students' current status of safety accidents and needs on the HE safety education. The respondents of the survey were the 512 students of one ${\bigcirc}{\bigcirc}$ Girls' Middle School in Busan. And then, the seven integrated themes were selected, each seven integrated theme-networks were formed, and safety theme-based Home Economics curriculum and learning materials were developed. The results of this study were as the follows. The safety education content has continually been included from the first HE curriculum of 1954 to the 2015 revised HE curriculum. The middle school student respondents highly needed the content of 'the methods to deal with sexual violence and prostitution prevention', 'suicide prevention', and 'bullying net' for the HE safety education. All the 42 items were needed for the HE safety education by the respondents. The safety theme-based HE teaching learning process plans developed finally included the seven integrated themes, which were (1) dietary life safety, (2) adolescents' sex and safety, (3) adolescents' relationships with friends and safety, (4) family life and safety, (5) dwelling life and safety, (6) adolescents' egos and safety, and (7) social environment and safety. Each integrated theme consisted of three to six small themes, which amounted to total 28(for 35 lessons). Each small theme was presented with learning objectives and particular goals. The total 157 learning materials including the Home Economics curriculum were developed, which offered learning objectives and content for each safety theme, total 28 teaching and learning plans(for 35 lessons) were developed, which offered specific instructions for the easy implementation of the curriculum in the classroom, 28 PPTs, 25 film materials, four reading materials, 61 workbooks, 14 activity sheets, 16 evaluation sheets, 3 test sheets, 2 reference materials, and 4 learning material models(the refrigerator model, traffic lights for discussions, food tray model and stickers, and food mileage card). In this study, the safety education themes of 'clothing life and safety', 'conflict and safety', 'professional life and safety', and 'consumer and safety' were not addressed because these theme were not needed highly by the respondents. Therefore, for the further development of the teaching learning process plans for the HE safety education, it is necessary to develop and evaluate the teaching learning process plans to address the themes of 'clothing life and safety', 'conflict and safety', 'professional life and safety', and 'consumer and safety'.

A STUDY OF INTRAORAL ANATOMIC LANDMARKS OF KOREAN ADULT-UPPER JAW (성인 유치악자 상악골의 악궁과 치열궁의 형태에 관한 조사)

  • Oh, Yu-Ree;Lee, Sung-Bok;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.753-768
    • /
    • 1995
  • For accurate impression taking of dental patient and esthetic denture treatment of ednetulous patient, measuring between intraoral anatomic landmarks is useful.In this study the subjects selected at a random were two-jundred forty persons with a mean age 22.5(range 21-24) and were taken impression of by irreversible hydrocolloid impression material(Alginate). On the study model made by dental stone, each individual tray was made and final impresion was taken by border moilding. On final model measurings were performed with 3-dimensional measuring device and the values were analyzed by t-test The results is following : ABOUT THE MEASURED VALUES. 1. The width between maxillary right and left canine cusp tip was average 36.44mm(s.d. 2.48), man 36.67mm, woman 35.83mm(p<0.05). 2. The width between labial height of contour of maxillary right and left canine was average 40.08mm(s.d. 2.42), man 40.29mm, woman 39.52mm(p<0.05). 3. The width between mesio-lingual cusps of maxillary first molar was average 43.14mm(s.d. 3.33), man 43.56mm, woman 42.05mm(p<0.05). 4. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary first molar was average 64.89mm(s.d. 3.88), man 65.58mm, woman 62.92mm(p<0.05). 5. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary second molar was average 68.58mm(s.d. 3.91), man 69.29mm, woman 66.30mm (p<0.05). 6. The width between right and left hamular notch was average 49.80mm(s.d. 3.96), man 50.70mm, woman 48.20mm(p<0.05). 7. The length from labial heigth of contour of maxillary central incisor to center of incisive papilla was average 9.52mm(s.d. 1.18), man 9.46mm, woman 9.63mm(p>0.05). 8. The length from labial heigth of contour of maxillary central incisor to palatine fovea was average 53.27mm(s.d. 2.93), man 53.93mm, woman 52.08mm(p<0.05). 9. The center of incisive papilla ws located posterior to intercanine line at 0.40mm(s.d. 1.16), man 0.51mm, woman 0.11mm(p<0.05). 10. The height from incisal edge of maxillary central incisor to the labial vestibule was average 21.84mm(s.d. 1.38), man 22.01mm, woman 21.00mm(p<0.05). 11. The height from mesiolingual cusp of maxillary first molar to buccalvestible was average 17.45mm(s.d. 1.42), man 17.56mm, woman 17.08mm(p>0.05). 12. The height from hamular notch to standard occlusal plane was average 6.84mm(s.d. 1.06), man 6.91mm, woman 6.70mm(p>0.05). 13. The height from the deepest point of palatal vault to standard occlsalplane was average 19.95 mm(s.d. 2.03), man 20.19mm, woman 19.12mm(p<0.05). ABOUT THE ARCH FORM 1. The arch form was able to classify into four typr by the rate of the measured values. Each arch form distribution was that the 1 group had 32.46% the 2 group 2.19%, the 3 group 52.83%, the 4 group 12.72%. The sexual composition was that in 1 group man had 73.5%, woman 26.5%, in 2 group man had 40.0%, woman 60.0%, in 3 group man had 83.3%, woman 16.7%, and in 4 group man had 55.17%, woman 44.83%. 2. When canine cusp tip was marked as point O, the intersection point between labial height of contour of maxillary central incisor and intermaxillary suture as point A, height of contour of maxillary second molar buccal alveolar ridge as B point, ${\angle}$AOB was measured $133.8^{\circ}$for the 1 group, $133.0^{\circ}$for the 2 group, $132.3^{\circ}$for the 3 group, $128.9^{\circ}$for the 4 group.

  • PDF

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.