• Title/Summary/Keyword: Mode reduction

Search Result 1,262, Processing Time 0.023 seconds

Dynamic Modeling of Bolt Joints Using Lumped Mass-Spring Model (집중 질량-스프링 모델을 이용한 볼트 결합부 모델링)

  • Go, Gang-Ho;Lee, Jang-Mu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.495-501
    • /
    • 2001
  • In this paper, a new technique which models the joints characteristics through reduction of DOFs of structures with joints using component mode synthesis (CMS) method is proposed. Bolt joints are modeled by mass-spring systems. Also generalized mass and stiffness matrices for this models are introduced. Because bolt joints have influence on eigenvalues of structures, exact eigenvalues from modal test are used. The results show that the behaviors of structures with bolt joints depend to a large extent on the translational DOFs and not on rotational DOFs of mass and stiffness matrices of bolts. Furthermore it is confirmed that lumped mass-spring systems as models of bolt joints are effective models considering the facts that joint characteristics converged to constant values in some iterations and eignevalues from proposed method are in good agreement with ones from modal test.

Reduction of Booming Noise Using Damper Clutch Disk on the Drive Shaft of Commercial Small Truck (상업용 소형 트럭의 구동축에서 댐퍼 클러치 디스크를 이용한 부밍 소음 저감)

  • Kim, Yong Dae;Choi, Byungjae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.377-383
    • /
    • 2015
  • Torsion mode or bending mode of drive-line for rear-wheel drive vehicle exists in low frequency band. If resonance exists there between natural mode of driveline and powertrain excitation force, drive-line will manifest excessive vibration response. Also, the vibration response can be transmitted to vehicle body and can induce booming noise. A vehicle in this study exhibits a booming noise problem under specific transmission gear condition. To draw performance improvement plan, finite element analysis technique was used. Modification was evaluated qualitatively and priorities were derived. Finally, effectiveness of best modification was verified through test and full vehicle FE analysis.

Improved Space Vector Modulation Strategy for AC-DC Matrix Converters

  • Liu, Xiao;Zhang, Qingfan;Hou, Dianli;Wang, Siyao
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.647-655
    • /
    • 2013
  • In this paper, an approach to reduce the common-mode voltage and to eliminate narrow pulse for implemented AC-DC matrix converters is presented. An improved space vector modulation (SVM) strategy is developed by replacing the zero space vectors with suitable pairs of active ones. Further, while considering the commutation time, the probability of narrow pulse in the conventional and proposed SVM methods are derived and compared. The advantages of the proposed scheme include: a 50% reduction in the peak value of the common-mode voltage; improved input and output performances; a reduction in the switching loss by a reduced number of switching commutations and a simplified implementation via software. Experimental results are presented to demonstrate the correctness of the theoretical analysis, as well as the feasibility of the proposed strategy.

Three-Phase Common-Mode Active EMI Filters for Induction Motor Drive Applications

  • Tarateeraseth, Vuttipon
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.871-878
    • /
    • 2018
  • In this paper, the conducted EMI reduction performances of active feed-forward current-sensing current-actuation (CSCA) and voltage-sensing current-actuation (VSCA) filters for a three-phase induction motor drive system are evaluated by experiments. For comparison purposes, the conducted EMI (CM emission, DM emission and total emission) of a three-phase induction motor drive with a conventional CM choke, a conventional CM choke in series with an active VSCA filter, and an active CSCA filter (where the CM choke was modified and used as a sensing current transformer) were compared to the case of a system without any filter inserted. Experimental results show that the active CSCA and VSCA filters can improve the CM reduction performance of the conventional CM choke by about 5 dB especially at low-frequencies. However, for DM comparisons, it shows that there is no different between cases with and without filters inserted.

Image Noise Reduction Using Structural Mode Shaping for Scanning Electron Microscopy

  • Hamochi, Mitsuru;Wakui, Shinji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.28-33
    • /
    • 2008
  • In a scanning electron microscope (SEM), outside acoustic noise causes image noise that distorts observations of the specimen being examined. A SEM that is less sensitive to acoustic noise is highly desirable. This paper investigates the image noise problem by addressing the mode shapes of the base plate and the transmission path of the acoustic noise and vibration. By arranging the position of the rib, a new SEM base plate was developed that had twisting as the 1st and 2nd modes. In those two twisting modes, vibration nodes existed near the center of the base plate where the specimen chamber is placed. Less vibration was transmitted to the chamber and to the specimen by the twisting modes compared to bending ones, which are the 2nd and 3rd modes for a rectangular plain base plate. An SEM with the developed base plate installed exhibited a significant reduction of image noise when exposed to acoustic noises below 250 Hz.

The Evaluation on Smoke Reduction by Natural Gas Dual Fuel Engine for City Bus (매연저감을 위한 천연가스 Dual-Fuel 엔진의 시내버스 적용평가)

  • 엄명도;조강래;오용석;한영출
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.215-220
    • /
    • 1997
  • CNG dual fuel engine for heavy duty diesel engine developed by AFS International in Canada has been equipped to a Korean city bus engine and tested to compare the engine performance and the emission characteristics with the existing diesel fueled engine. Also the dual-fuel engine was applied to the city bus for road test. The results are summarized as follows. Performance optimization has been carried out to have engine power equivalent to or better than the diesel fueled engine. Smoke is decreased by 85% by Korean smoke 3 mode test. By 13 mode test CO is increased by 453% and THC is increased by 2, 086%. NOx is decreased by 7% in laboratory. D-13 test mode was changed in 1996 Korean regulation. Even though THC is increased very much, it's not too serious problem since CO and HC emission of diesel engine is very little compared to gasoline engine and more than 75% of THC is CH$_4$. But the reduction technologies of CO and HC has to be considered.

  • PDF

Sub-1.2-V 1-Gb Mobile DRAM with Ultra-low Leakage Current (극저 누설전류를 가지는 1.2V 모바일 DRAM)

  • Park, Sang-Kyun;Seo, Dong-Il;Jun, Young-Hyun;Kong, Bai-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.433-434
    • /
    • 2007
  • This paper describes a low-voltage dynamic random-access memory (DRAM) focusing on subthreshold leakage reduction during self-refresh (sleep) mode. By sharing a power switch, multiple iterative circuits such as row and column decoders have a significantly reduced subthreshold leakage current. To reduce the leakage current of complex logic gates, dual channel length scheme and input vector control method are used. Because all node voltages during the standby mode are deterministic, zigzag super-cutoff CMOS is used, allowing to Preserve internal data. MTCMOS technique Is also used in the circuits having no need to preserve internal data. Sub-1.2-V 1-Gb mobile DDR DRAM employing all these low-power techniques was designed in a 60 nm CMOS technology and achieved over 77% reduction of overall leakage current during the self-refresh mode.

  • PDF

Carrier Based LFCPWM for Leakage Current Reduction and NP Current Control in 3-Phase 3-Level Converter (3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 캐리어 기반 LFCPWM)

  • Lee, Eun-Chul;Choi, Nam-Sup
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.446-454
    • /
    • 2022
  • This study proposes a carrier-based pulse width modulation (PWM) method for leakage current reduction and neutral point (NP) current control in a three-phase three-level converter, which is a carrier-based PWM version of the previously proposed low-frequency common mode voltage PWM. Three groups of space vectors with the same common mode voltage are used. When the averaged NP current needs to be positive or negative, the specific groups are employed to produce low-frequency common mode voltages. The validity of the proposed PWM method is verified through experiments.

A Study on the Combustion Characteristics of a Hybrid Cyclone Jet Combustor (하이브리드 사이클론 제트 연소기의 연소특성에 관한 연구)

  • Jung, Won-Suk;Hwang, Chul-Hong;Lee, Gyou-Young;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.149-155
    • /
    • 2002
  • A promising new approach to achieve low pollutants emission and improvement of flame stabilities is tested experimentally using a hybrid cyclone jet combustor employing both premixed and diffusion combustion mode, Three kind of nozzles are used for LNG(Liquified Natural Gas) as a fuel. The combustor is operated by two method, One is ATI(Air Tangential Injection) mode, generated swirl flow by air as general swirl combustor, and the other is PTI(Premixed gas Tangential Injection) mode, The PTI mode consists of diffusion flame of axial direction and premixed cyclone flame of tangential direction in order to stabilized the diffusion flame. The results showed that the stable region of the PTI mode is more larger than the ATI mode. In addition, the reduction of NOx emission in PTI mode, as compared with that for the ATI mode is at least 50% in stable region. Also, even using the low calorific fuel as $CO_2$-blended gas, the cyclone jet combustor has high performance of flame stability.

  • PDF

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.