• Title/Summary/Keyword: Mode frequency

Search Result 4,300, Processing Time 0.031 seconds

A Self-Timed Ring based Lightweight TRNG with Feedback Structure (피드백 구조를 갖는 Self-Timed Ring 기반의 경량 TRNG)

  • Choe, Jun-Yeong;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.268-275
    • /
    • 2020
  • A lightweight hardware design of self-timed ring based true random number generator (TRNG) suitable for information security applications is described. To reduce hardware complexity of TRNG, an entropy extractor with feedback structure was proposed, which minimizes the number of ring stages. The number of ring stages of the FSTR-TRNG was determined to be a multiple of eleven, taking into account operating clock frequency and entropy extraction circuit, and the ratio of tokens to bubbles was determined to operate in evenly-spaced mode. The hardware operation of FSTR-TRNG was verified by FPGA implementation. A set of statistical randomness tests defined by NIST 800-22 were performed by extracting 20 million bits of binary sequences generated by FSTR-TRNG, and all of the fifteen test items were found to meet the criteria. The FSTR-TRNG occupied 46 slices of Spartan-6 FPGA device, and it was implemented with about 2,500 gate equivalents (GEs) when synthesized in 180 nm CMOS standard cell library.

A Low Power Voltage Controlled Oscillator with Bandwidth Extension Scheme (대역폭 증가 기법을 사용한 저전력 전압 제어 발진기)

  • Lee, Won-Young;Lee, Gye-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • This paper introduces a low-power voltage-controlled oscillator(VCO) with filters that consist of resistors and capacitors. The proposed VCO contains a 5-stage current mode buffer, and each buffer cell has a resistor-capacitor filter that connects input and output terminals. The filter adds a zero to the buffer cell. Because the zero moves the oscillation condition to high frequencies, the proposed VCO can generate a high frequency clock with low power consumption. The proposed circuit has been designed with 0.18 ㎛ CMOS process. The power consumption is 9.83 mW at 2.7 GHz. The proposed VCO shows 3.64 pJ/Hz in our simulation study, whereas the conventional circuit shows 4.79 pJ/Hz, indicating that our VCO achieves 24% reduction in power consumption.

Unsteady Pressure Oscillations of Liquefied Paraffin Wax Combustion in Hybrid Rocket (파라핀-왁스를 사용하는 하이브리드 로켓 연소의 비정상 압력 진동)

  • Hyun, Wonjeong;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.5
    • /
    • pp.339-347
    • /
    • 2022
  • The post chamber in hybrid rocket is installed to induce additional increase in combustion enthalpy by allowing continuous burning of the liquefied fuels. When paraffin wax fuel is used, unsteady pressure oscillations are observed only at the beginning of combustion. This study intends to investigate the effect of additional combustion of liquefied fuel droplets on the occurrence of unsteady pressure fluctuations. For this, the combustion in post-chamber was visualized and image analysis using POD(Proper Orthogonal Decomposition) technique was performed. In addition, the hypothesis was proposed on the occurrence of unsteady pressure oscillations by identifying the modes including the behavior of droplets through mode reconstruction. Conducting a series of combustion tests, the amount of liquefied fuel flowing into the post chamber and the generation of fuel droplets were controlled. Also, the changes in frequency characteristic of unsteady pressure oscillation were monitored. As a result, the unsteady pressure oscillations observed in paraffin wax combustion were the result of additional combustion of fuel droplets generated in the post chamber.

Experimental investigation on the degradation of SiGe LNAs under different bias conditions induced by 3 MeV proton irradiation

  • Li, Zhuoqi;Liu, Shuhuan;Ren, Xiaotang;Adekoya, Mathew Adefusika;Zhang, Jun;Liu, Shuangying
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.661-665
    • /
    • 2022
  • The 3 MeV proton irradiation effects on SiGe low noise amplifier (LNA) (NXP BGU7005) performance under different voltage supply VCC (0 V, 2.5 V) conditions were firstly experimental studied in this present work. The S parameters including S11, S22, S21, 1 dB compression point and noise figure (NF) of the test samples under different bias voltage supply were measured and compared before and after 3 MeV proton irradiation. The total proton irradiation fluence was 1 × 1015 protons/cm2. The maximum degradation quantities of the gain S21 and NF of the test samples under zero bias are measured respectively 1.6 dB and 1.2 dB. Compared with the samples under 2.5 V bias supply, the maximum degradation of S21 and NF are respectively 1.1 dB and 0.8 dB in the whole frequency band. It is noteworthy that the gain and NF of SiGe LNAs under zero-bias mode suffer enhanced degradation compared with those under normal bias supply. The key influence factors are discussed based on the correlation of the SiGe device and the LNA circuit. Different process of the ionization damage and displacement damage under zero-bias and 2.5 V bias voltage supply contributed to the degradation difference. The underlying physical mechanisms are analyzed and investigated.

Filtration of dispersed nanoparticles using cyclone and ultrasonic atomization (초음파 무화 및 사이클론을 이용한 분산된 나노입자의 여과법)

  • Jung, Jihee;Kim, Moojoon;Kim, Jungsoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • In order to overcome the limitation of conventional nanoparticle dispersion methods such as sonicator or homogenizer, a filtration method using an ultrasonic atomization effect and cyclones was proposed in this study. A 0.5 wt% suspension was made with Al2O3 powder with an average diameter of 250 nm. The suspension was filtered by the proposed method after pre-dispersing using a sonicator and a homogenizer, respectively. As the result, in the case of the suspension after pre-dispersing with a sonicator, the particle size distribution of the filtered suspension started showing up a single normal distribution indicating the mode of the average diameter only after the 3rd cyclone process. On the other hand, in the case of the suspension with the homogenizer pre-dispersion, similar results appeared from the 2nd cyclone process. Filtration of various types of nanoparticles is expected to be possible by adjusting ultrasonic atomization frequency and manipulating the design of the cyclone.

Evaluation of transcutaneous electrical nerve stimulation as an adjunct therapy in trigeminal neuralgia - a randomized double-blind placebo-controlled clinical study

  • Bisla, Suman;Gupta, Ambika;Agarwal, Shalini;Singh, Harneet;Sehrawat, Ankita;Singh, Aarti
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.6
    • /
    • pp.565-574
    • /
    • 2021
  • Background: Trigeminal neuralgia (TN) is a severe form of pain that affects the daily activities of a patient. Transcutaneous electrical nerve stimulation (TENS) therapy is an emerging option for the treatment of acute and chronic pain. The aim of this study was to evaluate the effect of TENS therapy as an adjunct to drug therapy for the treatment of TN. Methods: A total of 52 patients diagnosed with TN according to the International Classification of Headache Disorders (version 3) were included. Each patient was randomized to either the TENS or placebo TENS groups. Intervention was given in continuous mode and 100-Hz frequency for 20 mins biweekly for 6 weeks. Parameters were measured at baseline, TENS completion and 3 months, 6 months, and 1 year of follow up. The parameters observed were mean carbamazepine dose, mean visual analog scale (VAS) score, mean present pain intensity (PPI) score, and functional outcome. Non-parametric analyses, one-way ANOVA and the Kruskal-Wallis test were applied for intragroup comparisons, while the Mann-Whitney U test and independent t-test were used for intergroup comparisons of variables. The chi-square test was applied to analyze categorical data. Results: Compared to the placebo TENS group, the mean dose of carbamazepine in the TENS group was significantly reduced at TENS completion, as well as at 6 months and 1 year follow up. Changes in mean VAS score, mean PPI score, and functional outcome did not show significant differences between the groups (P>0.05). Conclusion: TENS therapy does not lead to any changes in pain levels but it may reduce the mean dose of carbamazepine when used as an adjunct treatment in patients with TN.

Patent Keyword Analysis using Gamma Regression Model and Visualization

  • Jun, Sunghae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.143-149
    • /
    • 2022
  • Since patent documents contain detailed results of research and development technologies, many studies on various patent analysis methods for effective technology analysis have been conducted. In particular, research on quantitative patent analysis by statistics and machine learning algorithms has been actively conducted recently. The most used patent data in quantitative patent analysis is technology keywords. Most of the existing methods for analyzing the keyword data were models based on the Gaussian probability distribution with random variable on real space from negative infinity to positive infinity. In this paper, we propose a model using gamma probability distribution to analyze the frequency data of patent keywords that can theoretically have values from zero to positive infinity. In addition, in order to determine the regression equation of the gamma-based regression model, two-mode network is constructed to visualize the technological association between keywords. Practical patent data is collected and analyzed for performance evaluation between the proposed method and the existing Gaussian-based analysis models.

Investigation of 0.5 MJ superconducting energy storage system by acoustic emission method.

  • Miklyaev, S.M.;Shevchenko, S.A.;Surin, M.I.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.961-965
    • /
    • 1998
  • The rapid development of small-scale (1-10 MJ) Superconducting Magnetic Energy Storage Systems (SMES) can be explained by real perspective of practical implementation of these devices in electro power nets. However the serious problem of all high mechanically stressed superconducting coils-problem of training and degradation (decreasing) of operating current still exists. Moreover for SMES systems this problems is more dangerous because of pulsed origin of mechanical stresses-one of the major sources of local heat disturbances in superconducting coils. We investigated acoustic emission (AE) phenomenon on model and 0.5 MJ SMES coils taking into account close correlation of AE and local heat disturbances. Two-coils 0.5 MJ SMES system was developed, manufactured and tested at Russian Research Center in the frames of cooperation with Korean Electrical Engineering Company (KEPCO) [1]. The two-coil SMES operates with the stored energy transmitted between coils in the course of a single cycle with 2 seconds energy transfer time. Maximum operating current 1.55 kA corresponds to 0.5 MF in each coil. The Nb-Ti-based conductor was designed and used for SMES manufacturing. It represents transposed cable made of Nb-Ti strands in copper matrix, several cooper strands and several stainless steel strands. The coils are wound onto fiberglass cylindrical bobbins. To make AE event information more useful a real time instrumentation system was used. Two main measured and computer processed AE parameters were considered: the energy of AE events (E) and the accumulated energy of AE events (E ). Influence of current value in 0.5 MJ coils on E and E was studied. The sensors were installed onto the bobbin and the external surface of magnets. Three levels of initial current were examined: 600A, 1000A, 2450 A. An extraordinary strong dependence of the current level on E and E was observed. The specific features of AE from model coils, operated in sinusoidal vibration current changing mode were investigated. Three current frequency modes were examined: 0.012 Hz, 0.03 Hz and 0.12 Hz. In all modes maximum amplitude 1200 A was realized.

  • PDF

The Effect of Mobilization Combined with Shoulder Active Contraction of Depth between the Coracoid Process and Humeral Head (어깨의 능동 수축을 동반한 관절가동술이 부리돌기와 위팔뼈 머리 사이의 거리에 미치는 영향)

  • Sun-min Kim;Sang-hun Jang
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.2
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: This study examined the distance between the coracoid process and the humeral head using an ultrasonography device when shoulder active contraction were applied according to the guided direction in the end range of shoulder mobilization. This study aims to provide essential data on treating shoulder disease patients. Methods: The subjects of this study were 20 adults with healthy shoulder joints. ultrasonography (US) equipment was used to examine shoulder joint mobilization under two conditions: (1) anteroposterior (AP) joint mobilization and (2) superoinferior (SI) joint mobilization. Shoulder active contraction was assessed in the end range. The distance between the coracoid process and the humeral head was measured. A linear probe was used for US; the frequency was set to 7.5MHz, and the US image display method was set to B-mode. The US measurement values were measured in (1) the starting position, (2) the end range position, and (3) the end range position of the shoulder active contraction, and the moving distance was drawn in a straight line through the US image. The distance was determined as the measurement value, and the average values were compared. Reults: The results were as follows: (1) the measured AP Joint mobilization increased by an average of .52cm from the end range of the joint mobilization with shoulder active contraction; (2) the measured SI Joint mobilization increased by an average of .49cm from the end range of the joint. Conclusion: When shoulder mobilization is applied, the distance between the coracoid process and the humeral head increases when muscle contraction occurs through shoulder active contraction in the end range, according to the therapist's guidance. Therefore, shoulder mobilization combined with shoulder active contraction is an effective treatment method for patients with shoulder injuries.

  • PDF

Impact of COVID-19 Pandemic on Use of Reference Sources and Services by Postgraduates' in Kenneth Dike Library, University of Ibadan, Nigeria

  • Samson Oyeyini Akande;Olalekan Abraham Adekunjo
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.13 no.1
    • /
    • pp.27-41
    • /
    • 2023
  • The outbreak of the corona virus diseases (COVID-19) in the late 2019 has affected all facets of educational system including library and information services. Reference services, an important aspect of library services are not exempted from this impact. This study therefore, investigated the impact of COVI\D-19 pandemic on the use of reference services and sources by postgraduate students using Kenneth Dike Library (KDL), University of Ibadan, as a case study. Using descriptive survey of correlational type, the study adopted the use of structured questionnaire to randomly select three hundred (300) postgraduate users of reference sources and services in KDL using online survey monkey. Of the three hundred (300) copies, two hundred and twenty three (223) copies, repre- senting 74.3% were retrieved and used for analysis. Findings revealed that, in spite of COVID-19 pandemic, most postgraduate students used Current Awareness Services (203, 91.0%, mean = 3.19), Reference Sources (202, 90.5%, mean = 3.18) and On-line Public Access Catalogue (195, 87.4%, mean = 3.13); low frequency of bibliotherapy (mean=2.22), Reader's Advisory services (mean=2.30) and inter-library loan (mean=2.13) and that COVID-19 pandemic had high impact on post- graduate students' use of reference services in Kenneth Dike Library, University of Ibadan. Based on the findings, recommendations were made that library management should consider the adoption of virtual reference services (VRS) in addition to the conventional mode of refer- ence services to enhance patronage in the COVID-19 era. The library users should also be trained on how to take advantage of the COVID-19 pandemic to learn new skills in the digital space that will eventually optimize the usage of the library remotely.