• Title/Summary/Keyword: Mode conversion

Search Result 537, Processing Time 0.039 seconds

Observation of Strong In-plane End Vibration of a Cylindrical Shell

  • 길현권
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.183-183
    • /
    • 2002
  • In this paper, the strong in-plane vibration has been experimentally observed at the end of a finite cylindrical shell. The strong in-plane vibration was generated by the evanescent wave field, which was excited along about half the length of the shell. The evanescent waves were generated due to mode conversion of elastic waves at the ends of the cylindrical shells.

An Impedance Transformer with Unequal Split Based on S-Parameter Conversion (S-파라미터 변환을 통한 비대칭 분배되는 임피던스 변환기)

  • Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.4
    • /
    • pp.361-366
    • /
    • 2016
  • This paper presents an arbitrary impedance transformer with unequal split, based on S- to admittance parameter conversion. When compared even/ odd- mode analysis, the parameter conversion design method constitutes a simple design method to include phase delay information and arbitrary port impedances and asymmetrical configurations. To validate this design method, we designed a 50 to $12.5{\Omega}$ impedance transformer with a 3:1 unequal power split, at an operating frequency of 1 GHz. To implement the proposed impedance transformer, the low impedance transmission lines of calculated result are fabricated by the transmission line connected shunt open stub. Good experimental performances were obtained, in full agreement with simulated results.

The Surgery of Pulmonary Tuberculosis: 163 cases experience (폐결핵 수술: 163례 보고)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.109-115
    • /
    • 1988
  • With the decreasing incidence of new cases and the highly effective results with antituberculous drug therapy, there is a marked decline in the need for surgery which was formerly such an important part in the successful program of management of this disease. During the period of two years and a half from Jun. 1984 to Dec. 1986, this study represents an analysis of 163 cases of several surgical management for eventual control of pulmonary tuberculosis at National Kon-ju tuberculosis Hospital. 1. Mode of surgical treatment was: Resection; 123 cases [Pneumonectomy: 83, lobectomy: 35, lobectomy plus segmentectomy; 4 segmentectomy: 1], thoracoplasty: 20 and others: 20. 2. Age distribution ranged 16and 68 with average of 34 years. Male and female ratio was 1.2: 1. 3. Surgical indications were: totally destroyed lung; 64, Destroyed lobe of segment; 13, cavity positive sputum; 10, cavity c negative Sputum; 6, Bronchostenosis c atelectasis; 2, empyema c or s BPF; 46, Aspergilloma; 8, Questions of Associated tumor; 4 and other 5. 4. Incidence of Complications was 10.4% and the mortality was 5.5 percent. The cause of mortality were analyzed. The main causes of death were respiratory insufficiency; 4, fulminant hepatitis; 1, hemorrhage; 1 and unknown; 1 in pneumonectomy, and asphyxia; 1 in lobectomy and sepsis; 1 in other procedure. 5. Conversion rare of positive sputum to negative state related to resectional surgery was 91.5%. In pneumonectomy, drug resistant group preoperatively showed 88.1% conversion rate postoperatively and drug sensitive group showed that 100% conversion rate. In lobectomy, both drug resistant and sensitive groups showed that 100% conversion rate postoperatively.

  • PDF

Development of the fast setting PLL for MB-OFDM UWB system (MB-OFDM UWB System용 Fast Setting PLL 개발)

  • Lee, Young-Jae;Hyun, Seok-Bong;Tak, Geum-Young;Kim, Cheon-Soo;Yu, Hyun-Kyu
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.607-608
    • /
    • 2006
  • A CMOS phase-locked loop (PLL) which synthesizes frequencies between $6.336{\sim}8.976GHz$ in steps of 528MHz and settles in approximately 150ns using the 528MHz reference clock is presented. Frequency hopping between the bands in the each mode is critical point to design the PLL in multi-band orthogonal frequency division multiplexing (OFDM) because frequency switching between each band is less than 9.5ns. To achieve the fast loop settling, integer-N PLL that operates with the high reference frequency to meet the settling requirement is implemented. Two PLLs that operate at 9GHz and 528MHz is integrated and shows the band hopping lower than 1ns.

  • PDF

Low-Power Direct Conversion Transceiver for 915 MHz Band IEEE 802.15.4b Standard Based on 0.18 ${\mu}m$ CMOS Technology

  • Nguyen, Trung-Kien;Le, Viet-Hoang;Duong, Quoc-Hoang;Han, Seok-Kyun;Lee, Sang-Gug;Seong, Nak-Seon;Kim, Nae-Soo;Pyo, Cheol-Sig
    • ETRI Journal
    • /
    • v.30 no.1
    • /
    • pp.33-46
    • /
    • 2008
  • This paper presents the experimental results of a low-power low-cost RF transceiver for the 915 MHz band IEEE 802.15.4b standard. Low power and low cost are achieved by optimizing the transceiver architecture and circuit design techniques. The proposed transceiver shares the analog baseband section for both receive and transmit modes to reduce the silicon area. The RF transceiver consumes 11.2 mA in receive mode and 22.5 mA in transmit mode under a supply voltage of 1.8 V, in which 5 mA of quadrature voltage controlled oscillator is included. The proposed transceiver is implemented in a 0.18 ${\mu}m$ CMOS process and occupies 10 $mm^2$ of silicon area.

  • PDF

Thermophilic Sewage Sludge Digestion by Anaerobic Sequencing Batch Reactor (고온 협기성 연속회분식 공정에 의한 도시하수슬러지 소화)

  • 허준무;박종안;이종화;손부순;장봉기
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.130-138
    • /
    • 1999
  • The feasibility of municipal sewage sludge digestion was investigated by using thermophilic anaerobic sequencing batch reactor(ASBR). One-day settle time was enough for the high performance of solid-liquid separation. The conversion of semi-continuous mode to sequencing batch mode is easily achieved without any adverse effects, although the large amount of sludge equal to the volume ratio of 0.3~06 to reactor volume was added in the feed step of the start-up. The ASBRs had higher conversion capability of organics to biogas than the control reactor. Gas yields of the ASBRs were increased by the average of 50% over the control reactor across a range of hydraulic retention time(HRT)s from 10days to 5days. The thermophilic reactors showed higher gas production than mesophilic reactor. Removal efficiencies of organic matter exceeded 80% on the basis of supernatants, except that at the reactor. Solid-liquid separation was essential in the performance of the ASBR, especially, at the lower HFT. The ASBRs were highly efficient in the retention of activated biomass within the reactor. thus compensating for increased equivalent organic loading rate through increased solids retention times followed by the increased solids, while maintaining shorter HRTs.

  • PDF

A Wide Voltage-Gain Range Asymmetric H-Bridge Bidirectional DC-DC Converter with a Common Ground for Energy Storage Systems

  • Zhang, Yun;Gao, Yongping;Li, Jing;Sumner, Mark
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.343-355
    • /
    • 2018
  • A wide-voltage-conversion range bidirectional DC-DC converter is proposed in this paper. The topology is comprised of one typical LC energy storage component and a special common grounded asymmetric H-bridge with four active power switches/anti-parallel diodes. The narrow output PWM voltage is generated from the voltage difference between two normal (wider) output PWM voltages from the asymmetric H-bridge with duty cycles close to 0.5. The equivalent switching frequency of the output PWM voltage is double the actual switching frequency, and a wide step-down/step-up ratio range is achieved. A 300W prototype has been constructed to validate the feasibility and effectiveness of the proposed bidirectional converter between the variable low voltage side (24V~48V) and the constant high voltage side (200V). The slave active power switches allow ZVS turn-on and turn-off without requiring any extra hardware. The maximum conversion efficiency is 94.7% in the step-down mode and 93.5% in the step-up mode. Therefore, the proposed bidirectional topology with a common ground is suitable for energy storage systems such as renewable power generation systems and electric vehicles with a hybrid energy source.

Level Conversion Scheme for Improving Performance of RAID 5 on Single Disk Failure (단일디스크 고장시 RAID 5의 성능개선을 위한 레벨 전환 기법)

  • Jeon, Sang-Hoon;Chung, Hyun-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.2
    • /
    • pp.8-18
    • /
    • 1999
  • It is very important to recover data immediately at a single disk failure for critical applications such as multimedia storage systems. real-time systems and so on. As an efficient solution, this paper proposes that RAID level conversion scheme to improve the performance before a failed disk is replaced with a new disk. By using this scheme, it does not require an additional disk to recover data. Comparing with previous studies, this scheme is appropriate to low cost system that has not additional redundant device. The performance of proposed scheme is evaluated and analyzed with that of RAID level 5 for various requested sizes through the simulation. The results show that the performance of the proposed scheme is improved up to 20 percents compared with that of RAID level 5 at the failure mode and 80 percents at reconfigured mode.

  • PDF