• Title/Summary/Keyword: Mode Transition

Search Result 492, Processing Time 0.026 seconds

Electric Field Dependence Experiments and ab Initio Calculations of Three Cytosine Tautomers in Superfluid Helium Nanodroplets

  • Min, Ah-Reum;Lee, Seung-Jun;Choi, Myong-Yong;Miller, Roger E.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.3039-3044
    • /
    • 2009
  • We report the first electric field dependence IR spectra of three cytosine tautomers solvated in helium nanodroplets. By using an electric field dependence on the three lowest energy tautomers of cytosine and ab initio calculations, we are able to measure the vibrational transition moment angles (VTMAs), specifically for the $NH_2$ symmetric stretch (SS) mode in this study, with more precision; thus we have reassigned the previous $NH_2$ (SS) VTMA of 74$^{\circ}$ for the C1 tautomer to 85$^{\circ}$, which the latter is in excellent agreement with the ab initio value. Nonplanarity of the three lowest energy tautomers of cytosine has been investigated by measuring the VTMA of each vibrational mode for the tautomers.

Stability of the K rm n Boundary Layer Flow (Karman 경계층 유동의 안정성에 관한 연구)

  • 황영규;이윤용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.771-781
    • /
    • 2000
  • The Karman boundary-layer, has been numerically investigated for the disturbance wave number, wave velocity, azimuth angle and radius (Reynolds number, Re). The disturbed flow over rotating disk can lead to transition at a much lower Re than that of the well-known Type 1 mode of instability. This early transition is due to the excitation of the Type II mode. Presented are the neutral stability results concerning these modes by solving new formulated vorticity equations with consideration of whole convective terms. When the present numerical results are compared with the previously known results, the value of critical Re corresponding to Type I is moved from Rec,! =285.3 to 270.2 and the value corresponding to Type II is from $Re_{c,2}$=69.4 to 36.9, respectively. Also, the corresponding wave number is moved from $k_1$ =0.378 to $k_1$ =0.389 for Type I; from $k_2$ =0.279 to $k_2$=0.385 for Type II. For Type II, the upper limit of wave number and azimuth angle is $k_U$=0.5872,$varepsilon_U=-18^{\circ}$ , while its lower limit is$k_L$ =0.05, $varepsilon_L=-27^{\circ}$ This implies that the disturbances will be relatively fast amplified at small Re and within narrow bands of wave number compared with the previous results.

  • PDF

Full Wave Mode ZVT-PWM DC-DC Converters (전파형 ZVT-PWM DC-DC 컨버터)

  • 김태우;안희욱;김학성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • This paper proposes a full wave mode ZVT-PWM boost converter. The converter with the auxiliary switch in a full wave mode makes possible soft switching operation of all switches including the auxiliary switch whereas the auxiliary switch is turned off with hard switching in the conventional converter. Therefore, the proposed converter reduces the turn-off switching loss and switching noise of the auxiliary switch without additional passive and/or active elements and high power density system can be realized.

  • PDF

A Study on the Average Current-Mode Control AC/DC ZVT-Boost Converter with Active-Clamp Method (능동 클램프 방식을 이용한 AC/DC ZVT 승압형 컨버터의 평균전류모드 제어에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Kim, Pill-Soo;Lim, Nam-Hyuk;Yoon, Suk-Ho;Chang, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1005-1008
    • /
    • 2001
  • This paper presents average current-mode control AC/DC ZVT(Zero Voltage Transition) Boost Converter. This boost converter perceives feed forward signal of input and feedback signal of output for average current-mode control proposed converter employs active-clamp method for ZVT. This converter gives the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations. This converter also has a high efficiency by active-clamp method. The principle of operation, feature, and design considerations are illustrated and verified through the experiment with a 150W, 120kHz prototype converter.

  • PDF

Fabrication of Novel Dual Mode Resonator Using Superconducting Thin Film Grown by Pulsed Laser Deposition (펄스 레이저 증착법에 의한 YBCO 박막증착과 이중모드 공진기의 제작)

  • Park, Joo-Hyung;Lee, Sang-Yeol;Ahn, Dal
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1546-1548
    • /
    • 1998
  • Dual mode ring resonators(DMRR) have been fabricated using laser ablated $YBa_2Cu_3O_{7-x}$ superconducting thin films. The transition temperature of YBCO thin films were 85 - 88 K and the film thicknesses were about 5,000 $\AA$. Dual mode ring resonators were patterned by standard photolithography process and wet-etching. Then two-layer metal thin films (Ti/Ag) have been deposited for the ground plane on the back side of substrate by e-beam and thermal evaporation. The input/output feedline angles of each resonator were $60^{\circ}$, $100^{\circ}$, $180^{\circ}$. A network analyzer was used for testing the performance of the resonators in the frequency range of 6-13 GHz at 77 K.

  • PDF

Stability analysis of deepwater compliant vertical access riser about parametric excitation

  • Lou, Min;Hu, Ping;Qi, Xiaoliang;Li, Hongwei
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.688-698
    • /
    • 2019
  • If heave motion in the platform causes horizontal parametric vibration of a Compliant Vertical Access Riser (CVAR), the riser may become unstable. A combination of riser parameters lies in the unstable region aggravates vibrational damage to the riser. Change of axial tensile stress in the riser combined with its natural frequency and mode shape change results in mode coupling. In accordance with the state transition matrices of the riser in the coupled and uncoupled states, the stable and unstable regions were obtained by Floquet theory, and the vibration response under different conditions was obtained. The parametric excitation of the CVAR is shown to occur mainly in first-order unstable regions. Mode coupling may cause parametric excitation in the least stable regions. Damping reduces the extent of unstable regions to a certain extent.

A Broadband Half-Mode Substrate Integrated Waveguide Quadrature Wilkinson Power Divider Using Composite Right/Left-Handed Transmission Line

  • Eom, Dong-Sik;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2017
  • In this work, a broadband composite right/left-handed (CRLH) half-mode substrate integrated waveguide (HMSIW) quadrature Wilkinson power divider is proposed. The proposed CRLH-HMSIW quadrature power divider includes a microstrip Wilkinson power divider on the transition structure between the microstrip and HMSIW, and two thru transmission lines for the HMSIW and the CRLH-HMSIW. The measured amplitude, phase difference and isolation between the two output ports of the proposed structure have 1 dB, ${\pm}5^{\circ}$ and less than -15 dB in a wide frequency range of 4.1-6.68 GHz with 47.9% bandwidth, respectively.

Reference Point Projection Method for Improved Dynamics of Solar Array Hardware Emulation

  • Wellawatta, Thusitha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.126-128
    • /
    • 2018
  • Solar array simulator (SAS) is a special DC power supply that regulates the output voltage or current to emulate characteristics of photovoltaic (PV) panels. Especially, the control of SAS is a challenging task due to the nonlinearity in the output curve, which is dependent on irradiance as well as temperature and is determined by panel materials. Conventionally, both current-mode control and voltage-mode control should be alternated by partitioning the operating curve into multiple sections, which is not only for the measurement noise problem with the feedback sensing but also for the control stability issue near the maximum power point. However, the occurrence of transition among different controllers may deteriorate the overall performance. To eliminate the mode transitions, a novel single controller scheme has been introduced in this paper, where the reference operating projection technique enables simple, smooth and numerically stable control. Theoretical consideration on the loop stability issue is discussed and the performance is verified experimentally for the emulation of a PV panel data in view of stability and response speed.

  • PDF

Development of submersion sensors using multi-mode fibers spliced with a fiber Bragg grating (다중모드 광섬유 융착형 침수 감지 센서 개발)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun;Shim, Joon-Hwan;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.925-931
    • /
    • 2009
  • This paper reports a preliminary experimental investigation and characterization of an optical fiber-based submersion sensor system for applications in water flooding and leakage. The sensor system comprises a multi-mode fiber spliced with fiber Bragg grating and an intensity-based interrogator. Submersion tests were conducted in water-air and Glycerin-air environments. By the refractive index of the fiber-probe surrounding materials, the reflectance and the detecting power level is determined. When the probe is dipped into the water, the optical output power dramatically decreases from -7.5dBm to -17.5dBm. But, the center of Bragg wavelength is not affected in spite of external material changes. Temporal response characteristics of the sensor system is investigated to verify the real-time reaction. When the probe is immersed into the liquid, there is no transition time.

The Operating characteristics of Community Energy System(CES) with Grid connection and isolation (지역 에너지 시스템의 계통 연계 및 독립 운전 특성에 관한 연구)

  • Park, Y.U.;Kim, K.H.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.258-260
    • /
    • 2004
  • This paper analyse a operating characteristics when the Community Energy System (CES) is operated islanding mode. In the near future, CES might be one of major energy supply structures. The basic concept of CES is that it supplies electrical and thermal energy to the local customer loads through the islanded power network separated from the grid. The CES must be supplying local load with stable energy on the islanding mode, analysing necessary to thoroughly the operation feature. In order to show them, in this paper, we model the CES with 2.34 MVA DG and simulate the operating feature on the islanding mode of CES. The simulation results show that, in order to stability operate, the CES need the efficient load management and generation control schemes during the transition periods.

  • PDF