• 제목/요약/키워드: Mode Switching

검색결과 1,344건 처리시간 0.028초

Single cell gap polymer-stabilized blue-phase transflective LCDs using internal nanowire grid polarizer

  • Cui, Hong-Qing;Ye, Zhi-Cheng;Hu, Wei;Lin, Xiao Wen;Chung, T.C.;Jen, Tean-Sen;Lu, Yan-Qing
    • Journal of Information Display
    • /
    • 제12권3호
    • /
    • pp.115-119
    • /
    • 2011
  • Optically isotropic liquid crystal (LC) mixture such as blue-phase LC and nanostructured LC composites exhibit the advantages of fast response time, high contrast ratio and wide-viewing angle due to the induced birefringence along the horizontal electric field. Utilizing this mixture, a novel single cell gap in-plane switching-type polymer-stabilized blue-phase transflective liquid crystal display by embedding the nanowire grid polarizer as a polarization-dependent reflective polarizer in the R region is proposed. This device can be used as a normal black mode without any quarter-wave plate or patterned in-cell phase retarder. Moreover, the transmittance is identical to the reflectance so that it will be suitable for single gamma driving. Detailed electro-optic performances, such as voltage-dependent light efficiency and viewing angle of the proposed device configuration, are investigated.

Sensorless Control of a Single-Phase Switched Reluctance Motor Using Residual Flux

  • Yang, Hyong-Yeol;Shin, Duck-Shick;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.911-918
    • /
    • 2009
  • This paper presents a new sensorless control method for single-phase switched reluctance motors using induced electromotive force (EMF) due to the residual flux both on the stator and the rotor during phase commutation. The induced EMF falls to zero when the rotor pole moves away from the overlap with the stator pole. By detecting this instant, the speed and position of the rotor can be simply estimated. This method is very simple to implement and it is insensitive to variations in the system parameters as it does not require any stored magnetic data or offline inductance measurements but requires only measurements of the terminal voltage and a simple analog circuit. The proposed method is implemented on a 6/6 single-phase switched reluctance motor. However, it can also be implemented on a multiphase SRM regardless of the size, operation speed and switching mode of the motor hence making the proposed method viable to many applications. Simulation and experimental verification is provided to demonstrate the feasibility of the proposed method.

전기차 배터리 충전기용 강인한 단위 입력 역률 제어장치 (Robust and Unity Input Power Factor Control Scheme for Electric Vehicle Battery Charger)

  • 웬콩롱;이홍희
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.182-192
    • /
    • 2015
  • This study develops a digital control scheme with power factor correction for a front-end converter in an electric vehicle battery charger. The front-end converter acts as the boost-type switching-mode rectifier. The converter assumes the two roles of the battery charger, which include power factor control and robust charging performance. The proposed control scheme consists of a charging control algorithm and a grid current control algorithm. The scheme aims to obtain unity input power factor and robust performance. Based on the linear average model of the converter, a constant-current constant-voltage charging control algorithm that passes through only one proportional-integral controller and a current feed-forward path is proposed. In the current control algorithm, we utilized a second band pass filter, a single-phase phase-locked loop technique, and a duty-ratio feed-forward term to control the grid current to be in phase with the grid voltage and achieve pure sinusoidal waveform. Simulations and experiments were conducted to verify the effectiveness of the proposed control scheme, both simulations and experiments.

전력선통신을 이용한 선박 및 건축용 발열유리 온도제어 시스템 (Power Line Communication-based Heated Glass Temperature Control System)

  • 이수형;김인동
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.105-114
    • /
    • 2015
  • Heated glasses are widely used to prevent surface condensation and freezing in ship and building windows. This study proposes a heated glass temperature control system composed of power and control circuits to control the temperature of heated glasses. The proposed temperature control system adopts a digital controller instead of a conventional analog controller. Thus, the proposed system has better characteristics, such as precise setup and control of glass temperature, setup and control of output power, and control mode change between ON/OFF and phase controls. The system can also implement multi-functional control algorithms. The control characteristics are not dependent upon external disturbances, such as ambient temperature and electrical noises. Furthermore, the proposed temperature control system utilizes the power line communication (PLC) method to control the number of heated glasses without any extra communication lines. The system proposes a new communication protocol with strong immunity to electrical switching noises. A new sensorless algorithm is used to detect the temperature of the heated glass. This study presents the design guidelines in detail and its effectiveness are confirmed by implementing a 4-kw prototype temperature control system.

3상 전원 조건의 모터 구동 인버터 내압 저감을 위한 공진 강압형 DC/DC 컨버터 (Resonant Step-Down DC/DC Converter to Reduce Voltage Stresses of Motor Driving Inverter under 3-phase AC Utility Line Condition)

  • 강경수;김상언;이준환;노정욱
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.391-398
    • /
    • 2014
  • This paper presents a resonant step-down DC/DC converter to reduce the voltage stresses of a 3-phase inverter module under the three-phase AC utility line condition. Under this condition, a conventional 3-phase inverter module suffers from high voltage stresses as a result of the high rectified DC link voltage; hence, a high-cost high-voltage-rating inverter module must be used. However, using the proposed converter, a low-cost low-voltage-rating inverter module may be adopted to drive the motor even under the 3-phase AC line condition. The proposed converter, which can be realized with small size inductor and low-voltage-rating semiconductor devices, operates at a high-efficiency mode because of the zero-current switching operations of all the semiconductor devices. The operational principles are explained and a design example is provided in the study. Experimental results demonstrate the validity of the proposed converter.

산부인과 펄스형 $CO_2$ 레이저의 펄스모듈 특성에 의한 동작파형의 일정한 시스템의 구현 (Fixed system of action waveform by pulse module special quality of obstetrics and gynecology pulse style $CO_2$ laser relationship embodiment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.159-161
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

Investigation of Interplay between Driving Voltage of MZ Modulators and Bandwidth of Low-pass Filters in Duobinary Modulation Formats

  • Lee, Dong-Soo
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.11-17
    • /
    • 2006
  • We have theoretically investigated the effects of the interplay between the driving voltage of Mach-Zehnder(MZ) modulators and the bandwidth of low-pass filters(LPF) in 10[Gb/s] duobinary modulation systems. For the change of driving voltage ratios(driving voltage/switching voltage), the transmission performance has been evaluated over 200[km] of single-mode fiber(SMF) systems. For driving voltage ratios with smaller than 100[%], the transmission performance has been maintained and greatly affected by the bandwidth of LPFs than the driving voltage. For driving voltage ratios with larger than 100[%], the transmission performance has been degraded and is not sensitive to the bandwidth of LPFs. To see the limitation of driving voltage, we have reduced the driving voltage ratio to 50[%]. Our results suggest that 10[Gb/s] duobinary signals with driving voltage ratio with smaller than 100[%] have been transmitted over 200[km] SMF within 2[dB] power penalty without dispersion compensation. For the driving voltage ratio with 50[%], we have verified that the transmission performance was maintained.

무기막에서의 수형배향된 액정의 특성에 대한 연구 (Inorganic Thin film for Horizontal Aligned Liquid Crystal with Non-rubbing Technologies)

  • 최대섭;신호철
    • 한국위성정보통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.75-79
    • /
    • 2015
  • 본 연구에서는 폴리이미드 박막위에서의 수직 및 수평배향에서 혼합액정의 배향 특성에 대해서 연구하였다. 혼합액정은 러빙을 이용하여 배향처리하였으며, 러빙에 사용된 폴리이미드 박막은 알킬기를 Side Chain으로 가진 수직배향용 배향막과 그렇지 배향막으로 나누어서 프리틸트각 특성을 측정하였다. 실험결과 혼합액정을 사용하여 양호한 배향상태를 얻을 수 있었으며, 고온에서의 열 안정성에서도 우수한 특성을 보이는 것을 알 수 있었다. 또한 프리틸트각의 발생 원리를 이해하기 위해서 접촉각 측정을 실시하였으며, 이 둘이 밀접한 상관관계를 갖고 있음을 알 수 있었다

Novel Five-Level Three-Phase Hybrid-Clamped Converter with Reduced Components

  • Chen, Bin;Yao, Wenxi;Lu, Zhengyu
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1119-1129
    • /
    • 2014
  • This study proposes a novel five-level three-phase hybrid-clamped converter composed of only six switches and one flying capacitor (FC) per phase. The capacitor-voltage-drift phenomenon of the converter under the classical sinusoidal pulse width modulation (SPWM) strategy is comprehensively analyzed. The average current, which flows into the FC, is a function of power factor and modulation index and does not remain at zero. Thus, a specific modulation strategy based on space vector modulation (SVM) is developed to balance the voltage of DC-link and FCs by injecting a common-mode voltage. This strategy applies the five-segment method to synthesize the voltage vector, such that switching losses are reduced while optional vector sequences are increased. The best vector sequence is then selected on the basis of the minimized cost function to suppress the divergence of the capacitor voltage. This study further proposes a startup method that charges the DC-link and FCs without any additional circuits. Simulation and experimental results verify the validity of the proposed converter, modulation strategy, and precharge method.

고역률 초퍼-인버터 일체형 고주파 발생회로의 특성해석에 관한 연구 (A Study on Characteristic Analysis of High Frequency Generating Circuit Integrated Chopper-Inverter with High Power-Factor)

  • 원재선;박재욱;남승식;이봉섭;석줄기;김동희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권10호
    • /
    • pp.610-617
    • /
    • 2004
  • This paper presents a novel high frequency generating circuit integrated chopper-inverter using ZVS with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant inverter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications. fluorescent lamp and DC-DC converter etc.