• 제목/요약/키워드: Mode Sequence Change

검색결과 17건 처리시간 0.019초

무선 채널에서의 오류에 강인한 비디오 통신을 위한 채널 환경에 적응적인 참조 영상 세그먼트 선택(RPSS)기법 (Channel Adaptive RPSS(Reference Picture Segment Selection) Technique for Error-Resilient Video Communication over Wireless Channels)

  • 경정찬;;김성대
    • 한국통신학회논문지
    • /
    • 제25권3A호
    • /
    • pp.325-333
    • /
    • 2000
  • The proposed RPSS(Reference Picture Segment Selection) mode is the RPS mode in picture segment of the ISD mode. The RPS mode has the weakness that it has to change the whole reference picture even if transmission error occurs only in the small part of picture. If the RPS mode is applied only to an error-occurred part and a conventional coding scheme is applied to an error-free part, the higher coding efficiency can be obtained. Simulation results show that there is the optimal number of segment which provides that best performance with given environment such as the BER(Bit Error Rate) of wireless channels, the characteristics of imput sequence, what kind of RPSS mode is used, etc. To apply the channel-adoptive RPSS mode later, the scheme which can change the number of segment without INTRA refresh and spatial error propagation is proposed in this paper.

  • PDF

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

구조물 손상 탐지를 위한 경 방향 모드 압전 오실레이터 센서 개발 (Development of a Lateral Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure)

  • 노용래;김동영
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 논문에서는 사회기반시설의 손상탐지를 위한 경 방향모드 압전 오실레이터의 가능성을 연구하였다. 경 방향 모드 오실레이터 센서는 구조물의 주요부에 부착된 경 방향 모드 압전소자와 피드백 오실레이터 회로로 구성되어있다. 구조물의 손상은 구조물의 임피던스를 변화를 야기 시키며, 그 결과로 구조물의 공진 주파수가 변화하게 된다. 오실레이터 센서는 간단한 방법으로 이 공진 주파수 변화를 연속적으로 관측할 수 있다. 본 연구에서는 알루미늄 시편에 크랙의 크기와 개수를 인위적으로 변화 시키면서, FEM해석과 실험을 통해 경 방향 모드 압전 오실레이터 센서의 적용 가능성을 증명 하였다.

구조물 손상 탐지를 위한 두께 방향 모드 압전 오실레이터 센서 개발 (Development of a Thickness Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure)

  • 김동영;노용래
    • 한국음향학회지
    • /
    • 제26권2호
    • /
    • pp.95-101
    • /
    • 2007
  • 본 논문에서는 구조물의 손상탐지를 위한 두께 방향 모드 압전 오실레이터의 가능성을 연구하였다. 두께 방향 모드 오실레이터 센서는 구조물의 주요부에 부착된 두께 방향 모드 압전소자와 피드백 오실레이터 회로로 구성되어있다. 구조물의 손상은 구조물의 임피던스를 변화를 야기시키며, 그 결과로 구조물의 공진 주파수가 변하게 된다. 오실레이터 센서는 간단한 방법으로 이 공진 주파수 변화를 연속적으로 관측할 수 있다. 본 연구에서는 알루미늄 시편에 크랙의 크기와 개수를 인위적으로 변화시키면서, FEM해석과 실험을 통해 두께 방향 모드 압전 오실레이터 센서의 적용 가능성을 증명 하였다.

뇌기능 영상을 위한 TRFGE와 CGE 기법에서 자화율 효과의 정량적 해석 (Quantitative Analysis of Susceptibility Effects in TRFGE and CGE Sequences for Functional MRI)

  • 정순철;노용만;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.66-74
    • /
    • 1997
  • 혈액의 산소화와 불 산소화에 따른 국부적인 자화율 효과의 변화에 의한 자장의 불 균일성에 민감한 경사 자장 에코 기법은 현재의 뇌기능 MR 영상의 기본이 되고 있다. 일반적으로 이러한 경사 자장 에코기법은 $T2^{*}$ 혹은 BOLD효과에 의한 자장의 불 균일성의 증가가 신호의 감소로 나타난다. BOLD 효과는 주자장에 대한 핏줄의 방향이나 영상 형식, 즉, 횡단면, 관상면, 또는 시상면에 따라 달라진다. 그래서 영상 형식과 영상면에 대한 기울임 각에 따른 신호의 변화와 BOLD 효과의 변화에 대한 정량적인 연구를 하였다. 연구는 자화율 효과에 대해 다른 민감도를 가지는 TRFGE 와 CGE 기법으로 이루어졌다. 컴퓨터 모의 실험과 실험 결과를 본 논문에 나타내었다.

  • PDF

뇌기능 영상을 위한 TRFGE, CGE 기법에서 이미징 모드와 기울임 각의 변화에 따른 자화율 효과의 해석 (Analysis of Susceptibility Effects by Variation of Imaging Modes and Tilting Angles in TRFGE and CGE Sequences for fMRI)

  • 정순철;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.571-574
    • /
    • 1997
  • fMRI, functional MRI introduced recently appears based on the gradient echo technique which is sensitive to the field inhomogeneity developed due to the local susceptibility changes of blood oxygenation and deoxygenation. Common to all the gradient echo techniques is that the signal due to the susceptibility effects is generally decreased with increasing inhomogeneity due to the $T2^*$ effect or conventionally known as blood oxygenation level dependent (BOLD) effect. It is, also found that the BOLD sensitivity is also dependent on the imaging modes, namely whether the imaging is in axial, or coronal or sagittal mode as well as the directions of the vessels against the main magnetic field. We have, therefore, launched a systematic study of imaging mode dependent signal change or BOLD sensitivity as well as the signal changes due to the tilting angle of the imaging planes. Study has been made or both TRFGE sequence and CGE sequence to compare the distinctions of the each mode since each technique has different sensitivity against susceptibility effect. Method of computation and both the computer simulations and their corresponding experimental results are presented.

  • PDF

Response of dynamic interlaminar stresses in laminated plates under free vibration and thermal load

  • Zhu, S.Q.;Chen, X.;Wang, X.
    • Structural Engineering and Mechanics
    • /
    • 제25권6호
    • /
    • pp.753-765
    • /
    • 2007
  • The response histories and distribution of dynamic interlaminar stresses in composite laminated plates under free vibration and thermal load is studied based on a thermoelastodynamic differential equations. The stacking sequence of the laminated plates may be arbitrary. The temperature change is considered as a linear function of coordinates in planes of each layer. The dynamic mode of displacements is considered as triangle series. The in-plane stresses are calculated by using geometric equations and generalized Hooke's law. The interlaminar stresses are evaluated by integrating the 3-D equations of equilibrium, and utilizing given boundary conditions and continuity conditions of stresses between layers. The response histories and distribution of interlaminar stress under thermal load are presented for various vibration modes and stacking sequence. The theoretical analyses and results are of certain significance in practical engineering application.

대각선 방향으로 분할된 압전 진동 에너지 수확 장치의 성능 연구 (Performance Study of Diagonally Segmented Piezoelectric Vibration Energy Harvester)

  • 김재은
    • 대한기계학회논문집A
    • /
    • 제37권8호
    • /
    • pp.983-989
    • /
    • 2013
  • 본 연구에서 제안한 압전 진동 에너지 수확 장치는 기존 외팔보의 직사각형 면이 대각선을 따라 분할되어 2 개의 에너지 수확 단위로 구성되어 있다. 부 구조물은 주 구조물이 진동 에너지 원에 부착되는 방향과 반대 방향으로 주 구조물의 끝단에 부착되어 있으며, 각 에너지 수확 단위는 폐회로 상태의 고유 진동수가 일치하도록 설계되었다. 동일한 고유 진동수를 갖는 2 개의 구조물이 연결될 때 관찰되는 일반적인 현상과 달리, 제안된 구조에서는 고유 진동수 분리가 작으며, 1 차 및 2 차 모드의 순서가 바뀌어 나타난다. 이로 인해 출력 전력 역시 특정 주파수 근처에서 집중 생성된다. 상용 유한 요소 해석 소프트웨어를 사용하여 제안된 진동 에너지 수확 장치의 최대 생성 전력이 동일한 설치 영역 및 끝단 질량을 갖는 기존 외팔보 형태의 장치에 비해 실질적으로 향상됨을 보였다.

선박용 2.5[kW] HID 탐사등의 Soft-Start 방식에 의한 개방회로 전압과 점등전류 순차 제어 (Soft-Start Open Circuit Voltage and Constant Current Sequence Control of 2.5[kW] HID Search Lamp for Ship)

  • 박노식;권순재;이동희
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.45-51
    • /
    • 2008
  • 본 논문에서는 2.5[kW]급 선박용 HID 탐사등 조명을 위한 Soft-start 개방회로 전압 및 정전류 순차 제어 방식을 제안한다. 제안된 제어회로는 HID 탐사등의 안정적인 점등을 위하여 개방회로 전압과 점등 전류를 순차적으로 제어하는 방식으로, 특히 전원투입 상태에서의 안정성을 위하여 일정한 입력전압에 대해서 Soft-start 기법을 적용하여 개방회로 전압 제어모드로 동작하도록 설계되었다. 또한, 점등개시 신호의 입력에 따라 제어모드를 전압제어에서 전류 제어모드로 변경하여 단일 PWM 제어소자에서 동시에 처리하도록 하였다. 한편, 입력 노이즈 및 개방회로 전압의 검출을 간단한 원칩 마이크로 프로세서로 구현하여, 오동작 및 점등 실패에 대한 강인성을 부가하도록 하였다. 제안된 제어기는 실제 선박용 HID 탐사등의 적용 시험을 통하여 그 안정성을 시험하였다.

1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰 (Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia)

  • 이규수;심현;문지훈;오재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF