• 제목/요약/키워드: Mode Method

검색결과 8,062건 처리시간 0.036초

Efficient Design of Waveguide Filters Reducing Modal Interference through Cross-Shaped Slots

  • Kahng Sungtek
    • Journal of electromagnetic engineering and science
    • /
    • 제5권1호
    • /
    • pp.21-25
    • /
    • 2005
  • In this paper, a new method is suggested to improve the frequency responses of dual-mode waveguide-filters that employ cross-shaped slots. In accordance with this method, regarding one cross-shaped slot between two cavities, the horizontal(vertical) mode in one cavity can be designed to influence far less the vertical(horizontal) mode in cavity. Therefore, it improves the overall performances. A 4th-order dual-mode filter is taken as an example and it validates the method.

COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

단일 입.출력 선형시스템에 대한 슬라이딩 모드 관측기 설계 (A Design of Sliding Mode Observer for SISO Linear Systems)

  • 문형장;권성하;박승규;정은태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.24-24
    • /
    • 2000
  • This paper proposes a design method of sliding mode observer for SISO linear systems with a disturbance input. We first construct an observer with a constant gain matrix, a feedforward injection map and an external feedforward compensation signal input. Using the second Lyapunov method, we present a sufficient condition for the existence of sliding mode observer. The proposed observer guarantees that the state error trajectories enter a certain region in finite time and remain inside thereafter.

  • PDF

동축소법을 이용한 부분구조합성법 (Substructure Synthesis Method using Dynamic Reduction)

  • 박석주;박성현;김성우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.82-87
    • /
    • 2000
  • The component mode synthesis method(CMS) used for vibration analysis has demerit that error becomes larger, as degree of natural frequency grows higher. The reason of error occurrence is that Guyan's static reduction is used and the number of modes taken in each component is deficient. This paper proposes the substructure synthesis method using dynamic reduction to solve the problem from the component mode synthesis method. Computer simulation for the proposed method. FEM and the component mode synthesis method(CMS) on a rectrangular plate has been carried out to prove the avilability of the proposed method.

  • PDF

구분모드합성법을 이용한 증기터빈$\cdot$발전기축계의 진동해석 (Vibration Analysis of Steam Turbine-Generator Rotor System Using Component Mode Synthesis Method)

  • 양보석;김용한;최병근;이현
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.401-408
    • /
    • 1999
  • A method is presented for the vibration analysis of steam turbine-generator rotor system based on the component mode synthesis method. The motion of each component of the system is described by superposing constraint mode associated with boundary coordinates and constrained normal modes associated with internal coordinates. This method using real fixed-interface modes allows for significant reduction in system model size while retaining the essential dynamic characteristics of the lower modes. The capability of this method is demonstrated in the natural frequency and unbalance response analysis of the steam turbine-generator rotor system in which the dynamics of the pedestal is considered. The results by the present method are compared with finite element method and trnasfer matrix method in terms of the accuracy and computing time.

  • PDF

Identification of nonlinear elastic structures using empirical mode decomposition and nonlinear normal modes

  • Poon, C.W.;Chang, C.C.
    • Smart Structures and Systems
    • /
    • 제3권4호
    • /
    • pp.423-437
    • /
    • 2007
  • The empirical mode decomposition (EMD) method is well-known for its ability to decompose a multi-component signal into a set of intrinsic mode functions (IMFs). The method uses a sifting process in which local extrema of a signal are identified and followed by a spline fitting approximation for decomposition. This method provides an effective and robust approach for decomposing nonlinear and non-stationary signals. On the other hand, the IMF components do not automatically guarantee a well-defined physical meaning hence it is necessary to validate the IMF components carefully prior to any further processing and interpretation. In this paper, an attempt to use the EMD method to identify properties of nonlinear elastic multi-degree-of-freedom structures is explored. It is first shown that the IMF components of the displacement and velocity responses of a nonlinear elastic structure are numerically close to the nonlinear normal mode (NNM) responses obtained from two-dimensional invariant manifolds. The IMF components can then be used in the context of the NNM method to estimate the properties of the nonlinear elastic structure. A two-degree-of-freedom shear-beam building model is used as an example to illustrate the proposed technique. Numerical results show that combining the EMD and the NNM method provides a possible means for obtaining nonlinear properties in a structure.

동적 시스템의 잔류진동 제거를 위한 새로운 다모드 입력성형기 설계 방법 (A New Design Method for Multi-mode Input Shapers to Eliminate Residual Vibration in Dynamic Systems)

  • 박상원;홍성욱
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.100-106
    • /
    • 2009
  • The current tendency toward light weight and fast machines has lead to a need to suppress vibration of flexible dynamic systems. Input shaping is an efficient tool to eliminate transient and residual vibration caused by motion of these systems. This paper proposes a new formulation of the design method for multi-mode input shapers to eliminate residual vibration in flexible dynamic systems. The essence of the proposed method is to minimize the number of impulses to be n+1 for n-mode input shapers. This paper also suggests a solution procedure to solve the complex-valued nonlinear matrix equation for the input shapers. The proposed method is applied to two-mode input shapers. This paper discusses characteristics of several input shapers obtained under the same condition. Simulations and experiments show that the proposed method is very useful for designing multi-mode input shapers.

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

Ritz 벡터를 이용한 수정 분할구조해석법 (Modified Component Mode Synthesis Method Using Ritz Vectors)

  • 이인원;김동옥
    • 소음진동
    • /
    • 제3권1호
    • /
    • pp.77-82
    • /
    • 1993
  • In general, the dynamic analysis with FEM(Finite Element Method) of large structures requires large computer memory space and long computational time. For the purpose of economical dynamic analysis of large structures, most of engineers want to use an efficient solution algorithm. This paper reports the modified CMS(Component Mode Synthesis) method which uses more efficient algorithm than the classical CMS method. In this paper, it is shown that Ritz vector sets can play the role of normal mode vector sets of substurctures in the CMS algorithm. The modified CMS method has good convergence performance compared with that of the classical CMS method.

  • PDF

Two Switches Balanced Buck Converter for Common-Mode Noise Reduction

  • Kanjanasopa, Warong;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.493-498
    • /
    • 2004
  • The EMI noise source in a switching mode power supply is dominated by a common mode noise. If we can understand the common mode noise occurring mechanism, it is resulted to find out the method to suppress the EMI noise source in the switching mode power supply. The common mode noise is occurring mostly due to circuit is unbalanced which is caused by the capacitive coupling to frame ground, which passes through a heatsink of the switching devices. This research paper presents a new effective balancing method of buck converter circuit by mean of grounding the parasitic and compensation capacitors in correct proportion which is called that the common mode impedance balance (CMIB). The CMIB can be achieved by source, transmission line and termination balanced, such balancing, the common mode current will be cancelled out in the frame ground. The greatly reduced common mode noise can be confirmed by the experimental results.

  • PDF