• Title/Summary/Keyword: Modbus protocol

Search Result 40, Processing Time 0.038 seconds

A Programmable Protocol Data Conversion Algorithm for Industrial Machine Monitoring (산업용 장비 모니터링을 위한 프로그램 가능한 프로토콜 데이터 변환 알고리즘)

  • Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2139-2144
    • /
    • 2017
  • In case of communication method and protocol applied to the industrial field, various kinds and methods are applied to the field according to the environment and hardware configuration specifications. In order to develop and construct an industrial monitoring system, the development of the equipment is carried out through hardware system analysis and communication protocol analysis each time, so that a lot of development costs and time are being entered. In this paper, we proposed a programmable protocol conversion algorithm to support the integrated monitoring of industrial equipment using various protocols. This method can extract the necessary data from the data transmitted by serial communication, NMEA, CAN, Modbus communication method and transmit it to Ethernet. We implemented a communication gateway module that supports various communication methods, and experimented with data conversion and transmission.

Web-based Building Automation System using Embedded Linux (임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템)

  • 신은철;이수영;최병욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

Modbus TCP based Solar Power Plant Monitoring System using Raspberry Pi (라즈베리파이를 이용한 Modbus TCP 기반 태양광 발전소 모니터링 시스템)

  • Park, Jin-Hwan;Kim, Chang-Bok
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.620-626
    • /
    • 2020
  • This research propose and simulate a solar power generation system monitoring system based on Modbus TCP communication using RaspberryPi, an IOT equipment, as a master and an inverter as a slave. In this model, various sensors are added to the RaspberryPi to add necessary information for monitoring solar power plants, and power generation prediction and monitoring information are transmitted to the smart phone through real-time power generation prediction. In addition, information that is continuously generated by the solar power plant is built on the server as big data, and a deep learning model for predicting power generation is trained and updated. As a result of the study, stable communication was possible based on Modbus TCP with the Raspberry Pi in the inverter, and real-time prediction was possible with the deep learning model learned in the Raspberry Pi. The server was able to train various deep learning models with big data, and it was confirmed that LSTM showed the best error with a learning error of 0.0069, a test error of 0.0075, and an RMSE of 0.0866. This model suggested that it is possible to implement a real-time monitoring system that is simpler, more convenient, and can predict the amount of power generation for inverters of various manufacturers.

Design of Inner Section Displacement Measurement System Using Multiple Node Networks (다중 노드 네트워크를 이용한 내공변위 계측 시스템)

  • 서석훈;우광준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.20-26
    • /
    • 2001
  • In this paper, we design tunnel inner section displacement measurement system which is composed of potentiometer-type displacement sensors, microcontroller-based intelligent sensing head and host computer for the management system and acquisition data. Multiple node communication bus connects the intelligent sensing heads with the host computer. For safe and re1iab1e network operation we use daisy-chain configuration, termination resistor, fail-safe biasing circuit. For tole enhancement of system utilization, we use modbus protocol. The acquisition data are transmitted to host computer and managed by database. Several data request conditions and sorting conditions are provided by management software. The utilization of designed system is confirmed by experiment.

  • PDF

Smart Factory using IoT based on Wi-SUN (Wi-SUN 기반 IoT 활용 스마트 팩토리)

  • Kim, Dongwon;Yoon, Mi-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.522-523
    • /
    • 2022
  • In this paper, we design a gateway protocol architecture for building an IoT-based smart factory. A smart factory system consists of several terminal devices, gateways and servers, and connects them through a wireless network. The terminal device collects information from various sensors and transmits the information to the server through the gateway. The terminal device controls the actuator by receiving a control signal according to a control algorithm of the server or by manual operation. Therefore, the gateway system connects Wi-SUN, a wireless smart utility network, and the Internet, serves as a Wi-SUN coordinator, and is equipped with Modbus-TCP to interwork with SCADA.

  • PDF

A study of multi protocol communication on single serial interface (Serial 전송라인에서 Multi-Protocol 통신의 구현 연구)

  • Lee, Jae-Cheol;Ko, Dae-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.5
    • /
    • pp.464-469
    • /
    • 2008
  • The RS-232C (Unbalanced serial) and RS-485 (balanced serial) are standard in serial communication. RS-485 uses a differential electrical signal, as opposed to unbalanced signals referenced to ground with the RS-232. Differential transmission, which uses two lines each for transmit and receive signal results in greater noise immunity and longer distances as compared to the RS-232C. The greater noise immunity and distance are big advantages in industrial environments. In general, one protocol on one serial interface is very normal application. In this study, we implemented multi protocols on one serial RS-485 interface and examine the performance and result with hanging multi equipments.

  • PDF

Trends of IETF CoAP Based Sensor Connection Protocol Technology (IETF CoAP 기반 센서 접속 프로토콜 기술동향)

  • Ko, S.K.;Park, I.K.;Soon, S.C.;Lee, B.T.
    • Electronics and Telecommunications Trends
    • /
    • v.28 no.6
    • /
    • pp.133-140
    • /
    • 2013
  • 기존의 센서 접속 기술은 그 분야에 띠라 다양한 표준과 규격이 존재하였다. 빌딩 자동제어 및 제어 네트워크용으로는 BACnet이 있으며, 공장제어 및 계측제어를 위한 Modbus 등이 다양한 프로토콜이 존재한다. 최근 M2M(Machine-to-Machine) 및 IoT(Internet of Things), WoT(Web of Things) 시대로 접어 들음에 따라 센서 및 각종 디바이스 간에 상호 통신할 수 있는 공통 프로토콜이 필요하게 되었다. IoT 프로토콜로 IEIF(Internet Engineering Task Force) CoAP(Constrained Application Protocol) 프로토콜이 핵심 역할을 하고 있으며, 차세대 센서 접속 프로토콜로 IETF CoAP이 많이 사용될 것으로 예상된다. 본고에서는 IETF CoAP 표준화 동향 및 규격에 대해 살펴본다.

Web based control modules Using LonWorks/Ethernet Server for Control a large Scale Renewable Energy System in Building (빌딩용 신.재생에너지시스템 제어를 위한 LonWorks기반 원격 제어모듈 개발)

  • Hong, Wonl-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1706-1711
    • /
    • 2008
  • This paper proposes a new Web based-control concept & design method and implementation of LonWorks network system for a large scale renewable energy energy control and monitoring system in building. The Experimental LonWorks network system using LonWorks/Ethernet(Web) server is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting LonTalks protocol to Modbus protocol and software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, Especially, The seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide a available technical data for remote distributed control system of industrial and buildings field.

  • PDF

Development of the Gateway in IEC61850 based Substation for Smart Grid (스마트 그리드용 IEC61850 기반 변전소에서의 게이트웨이 개발)

  • Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1324-1330
    • /
    • 2011
  • This paper presents the development of gateway for smart grid for the interoperable communication between IEC 61850 station leveled devices and one of legacy Modbus, DNP3, and IEC60870-5-101/104/103 communication protocol devices of bay level in substation or for the exchange of information between IEC 61850 substation and SCADA control center. The data-mapping model is designed for the exchange of information and the gateway configuration tool is developed for generating meta-data based on XML Schema. this paper is mostly concerned with the design and realization of gateway system for the interoperable data communication between a legacy protocol device and IEC61850 based devices or systems.

The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data (유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안)

  • Kim, Yunha;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.