• 제목/요약/키워드: Modal Test

검색결과 717건 처리시간 0.03초

반도체 초정밀장비의 진동허용규제치를 고려한 지지구조의 동특성 개선에 관한 연구 (A Study on the Structural Dynamic Modification of Sub-structure of Clean Room Considering Vibration Criteria)

  • 손성완;이홍기;백재호
    • 반도체디스플레이기술학회지
    • /
    • 제2권2호
    • /
    • pp.25-30
    • /
    • 2003
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. This high technology equipments require very strict environmental vibration criteria in proportion to the accuracy of the manufacturing. In this paper, the dynamic analysis and modal test were performed to evaluate the dynamic properties of the constructing clean room structure. Based on these results, a structural dynamic modification(SDM) were required to satisfiy the vibration allowable limit for pression machine. Therefore, in order to improve the dynamic stiffness of clean room structure, the VSD system which can control the force applied on structure, were adopted and its utility were proved from dynamic test results of the improved structure after a modification work.

  • PDF

다양한 경계조건을 갖는 등방성 반구형셀의 자유진동해석 (Free vibration analysis of the isotropic hemi-spherical shell with various boundary condition)

  • 이영신;김현수;양명석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.831-836
    • /
    • 2000
  • In this study, the Rayleigh inextensional theory and extensional theory for thin shells was employed to predict the natural frequencies of the hemi-spherical shell with free and simply. supported boundary condition. The frequencies and mode shapes from theoretical calculation were compared with those of commercial finite element code, ANSYS. In order to validate the theory, modal test was also performed by impact test and FFT analysis. Modal test and FEM analysis of the free, simply supported and clamped boundary condition was also carried out.

  • PDF

회전축에 Thin-walled Cylinder가 결합된 회전체 시스템의 동적 해석 (Dynamic Analysis of a Rotor System Having Thin-walled Cylinder Combined with Its Shaft)

  • 최영휴;박선균;홍대선;정원지
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.631-636
    • /
    • 2000
  • In this paper a transfer method model was introduced in order to analyze critical speeds and vibration modes of a flexible rotor system, whose rotor shaft is cupped into and fitted with a thin-walled cylinder at its end. The computed analysis results were compared with those of the experimental modal test. Both results show good agreement each other. Furthermore the free-run(or run-down) test result for the real rotor system also shows that the proposed transfer matrix method modelling can be successfully applicable to analyzing accurate critical speeds(or natural frequencies) of the rotor system.

  • PDF

휠제동장치의 스퀼소음 제어를 위한 해석결과 분석 (Analysis of FE/test result for con011ing the squeal noise of wheel brake system)

  • 차정권;박영일;이동균;조동현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.595-600
    • /
    • 2009
  • Passengers in a vehicle feel uncomfortable due to squeal noise. Squeal noise, a kind of self-excited vibration, is generated by the friction force between the disc and the pad of the automobile. In this paper, modal analysis of wheel brake system was performed in order to prediction of squeal phenomenon. It was shown that the prediction of system instability is possible by FEM. Finite element model of that brake system was made. Some parts of a real brake was selected and modeled. The normal mode analysis method performs analyses of each brake system component. Experiment of modal analysis was performed for each brake components and experimental results were compared with analytical result from FEM. The complex eigenvalue analysis results compared with braking test. The analysis results show good correlation with braking test for the squeal frequency at an unstable mode.

  • PDF

Local damage detection of a fan blade under ambient excitation by three-dimensional digital image correlation

  • Hu, Yujia;Sun, Xi;Zhu, Weidong;Li, Haolin
    • Smart Structures and Systems
    • /
    • 제24권5호
    • /
    • pp.597-606
    • /
    • 2019
  • Damage detection based on dynamic characteristics of a structure is one of important roles in structural damage identification. It is difficult to detect local structural damage using traditional dynamic experimental methods due to a limited number of sensors used in an experiment. In this work, a non-contact test stand of fan blades is established, and a full-field noncontact test method, combined with three-dimensional digital image correlation, Bayesian operational modal analysis, and damage indices, is used to detect local damage of a fan blade under ambient excitation without use of baseline information before structural damage. The methodology is applied to detect invisible local damage on the fan blade. Such a method has a seemingly high potential as an alternative to detect local damage of blades with complex high-precision surfaces under extreme working conditions because it is a noncontact test method and can be used under ambient excitation without human participation.

새이중판 지지격자로 지지된 경수로용 연료봉의 진동특성 (Vibration Characteristics of the PWR Fuel Rod Supported by New Doublet Spacer Grids)

  • 최명환;강흥석;윤경호;김형규;송기남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.905-910
    • /
    • 2003
  • One of the methods that are used to compare and verify the supporting performance of the spacer grids developed is the vibration characteristic test. A modal test in this paper is performed for a dummy rod 3,847mm tall supported by eight New Doublet (ND) spacer grids. For the vibration test in air, nine accelerometers, one displacement sensor and one shaker are used for acquiring signals, and an I-DEAS TDAS software is employed for analyzing the signals. Also, a finite element (FE) analysis is performed by a beam-spring simple model and a contact model simulating the contact phenomenon between the rod and the fm spring. And then, the result of the FE analysis is compared with that of the modal test. The natural frequencies as well as the mode shapes calculated by the proposed contact models have a greater similarity to the test results than those by the previous beam-spring model. In addition, for grasping whether or not the modal parameters are influenced by where shaking spot is, two kinds of tests are performed; one is for the shaker attached at the fourth span (center), the other is for the shaker at the fifth span that is one span nearer to the bottom of the rod. The latter shows higher MAC than the former. Finally, the vibration displacements are measured in the range of 0.112-0.214mm for the excitation force of 0.25-0.75 N.

  • PDF

KAERI 채널형 전단벽체의 동적해석; 시스템판별, FE 모델향상 및 시간이력 응답 (Dynamic Analysis of a KAERI Channel Type Shear Wall: System Identification, FE Model Updating and Time-History Responses)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.145-152
    • /
    • 2021
  • KAERI has planned to carry out a series of dynamic tests using a shaking table and time-history analyses for a channel-type concrete shear wall to investigate its seismic performance because of the recently frequent occurrence of earthquakes in the south-eastern parts of Korea. The overall size of a test specimen is b×l×h =2500 mm×3500 mm×4500 mm, and it consists of three stories having slabs and walls with thicknesses of 140 mm and 150 mm, respectively. The system identification, FE model updating, and time-history analysis results for a test shear wall are presented herein. By applying the advanced system identification, so-called pLSCF, the improved modal parameters are extracted in the lower modes. Using three FE in-house packages, such as FEMtools, Ruaumoko, and VecTor4, the eigenanalyses are made for an initial FE model, resulting in consistency in eigenvalues. However, they exhibit relatively stiffer behavior, as much as 30 to 50% compared with those extracted from the test in the 1st and 2nd modes. The FE model updating is carried out to consider the 6-dofs spring stiffnesses at the wall base as major parameters by adopting a Bayesian type automatic updating algorithm to minimize the residuals in modal parameters. The updating results indicate that the highest sensitivity is apparent in the vertical translational springs at few locations ranging from 300 to 500% in variation. However, their changes seem to have no physical meaning because of the numerical values. Finally, using the updated FE model, the time-history responses are predicted by Ruaumoko at each floor where accelerometers are located. The accelerograms between test and analysis show an acceptable match in terms of maximum and minimum values. However, the magnitudes and patterns of floor response spectra seem somewhat different because of the slightly different input accelerograms and damping ratios involved.

모달시험기법을 이용한 침목플로팅궤도의 고유진동수 분석 (Natural Frequency Analysis of Sleeper Floating Track System using Modal Test Technique)

  • 최정열
    • 문화기술의 융합
    • /
    • 제10권3호
    • /
    • pp.833-838
    • /
    • 2024
  • 도시철도 침목플로팅궤도(STEDEF)는 침목상자와 침목방진패드를 이용하여 침목과 콘크리트 도상을 구조적으로 분리하여 콘크리트 도상에 전달되는 진동을 감소시키는 구조이다. 최근에는 20년 이상 공용중인 침목플로팅궤도의 침목방진패드 열화가 발생하고 있다. 이에 침목방진패드에 대한 성능을 평가하기 위해 침목방진패드 발췌 후 정적 스프링강성 시험을 수행하고 있다. 해당 평가기법은 사용 중인 침목방진패드를 반드시 교체한 후 평가를 수행한다. 그러나 궤도 고유진동수는 침목방진패드 스프링강성 및 콘크리트 도상의 융기와 침하에 따라 변화할 수 있다. 본 연구에서는 궤도 고유진동수를 평가하기 위해 모달시험기법을 사용하였다. 이를 위해 실험실 규모에서 침목상자 소재, 침목방진패드 스프링강성 및 콘크리트 도상 융기 및 침하에 따른 궤도 고유진동수를 모달시험을 이용하여 측정하였다. 침목플로팅궤도 고유진동수는 침목방진패드 스프링강성 변화에 따라 직접적인 영향을 받는 것으로 분석되었다. 또한 콘크리트 도상의 융기 및 침하에 따른 고유진동수 변화도 큰 것으로 나타났다. 따라서 본 연구에서 제시한 모달시험기법을 이용하여 침목방진패드의 열화 및 뜬 침목 평가 등에 활용할 수 있을 것으로 판단된다.

피로에 따른 PSC거더의 동적특성 변화 (Dynamic characteristic change of a PSC girder due to fatigue)

  • 최상현;이창수;신기훈;김태균
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1533-1538
    • /
    • 2011
  • The dynamic characteristics such as resonant frequencies and dampings have been utilized as important parameters in dynamic behavior and inverse analyses. In general, the dynamic parameters have been determined based on design and experimental data, but experimental studies on the time-dependent changes of the dynamic parameters during service have rarely been conducted. Especially, unlike highway bridges, it is much easier for railroad bridges to estimate accumulated amount of fatigue because of the controlled train operation, and the study of dynamic characteristic change due to fatigue is useful, since it can enhance the accuracy of dynamic analysis. In this paper, the dynamic characteristic change due to fatigue is measured via the modal test on the PSC girder during a fatigue test. The test specimen utilized in the test is the IT girder which enhances the sectional capacity of the conventional PSC girders. The test specimen is designed 10m long and the modal tests are conducted during the application of fatigue load two million times. The test result shows that considerable changes in the measured dynamic parameters are observed as the fatigue accumulates, and these changes during the service life should be considered in designing railroad bridges.

  • PDF

Mechanical verification logic and first test results for the Euclid spacecraft

  • Calvi, Adriano;Bastia, Patrizia;Suarez, Manuel Perez;Neumann, Philipp;Carbonell, Albert
    • Advances in aircraft and spacecraft science
    • /
    • 제7권3호
    • /
    • pp.251-269
    • /
    • 2020
  • Euclid is an optical/near-infrared survey mission of the European Space Agency (ESA) to investigate the nature of dark energy, dark matter and gravity by observing the geometry of the Universe and the formation of structures over cosmological timescales. The Euclid spacecraft mechanical architecture comprises the Payload Module (PLM) and the Service Module (SVM) connected by an interface structure designed to maximize thermal and mechanical decoupling. This paper shortly illustrates the mechanical system of the spacecraft and the mechanical verification philosophy which is based on the Structural and Thermal Model (STM), built at flight standard for structure and thermal qualification and the Proto Flight Model (PFM), used to complete the qualification programme. It will be submitted to a proto-flight test approach and it will be suitable for launch and flight operations. Within the overall verification approach crucial mechanical tests have been successfully performed (2018) on the SVM platform and on the sunshield (SSH) subsystem: the SVM platform static test, the SSH structure modal survey test and the SSH sine vibration qualification test. The paper reports the objectives and the main results of these tests.