• 제목/요약/키워드: Mock-up House

검색결과 27건 처리시간 0.026초

한국 노인의 부엌 및 욕실 설비에 대한 적정 치수 조사 (Survey on The Dimension of The Equipment Focus on Korean Elderly of Kitchen and Bathroom)

  • 주서령;이지예;김민경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.231-232
    • /
    • 2005
  • In the design guideline about the existing elderly house, the equipment related to kitchen and bathroom are the most important in the secure and functional aspect. On the other hand, the present elderly house is being designed according to foreign design guideline or common housing form instead of reflecting living and physical qualities of the korean elderly. Therefore, in this study based on the guideline of the existing literature, we made kitchen and bathroom equipments and conducted an experiment in finding proper position and height for korean elderly enough to use the kitchen and bathroom conveniently and independently. Based on the guideline of the existing literature related to foreign and domestic elderly house, we made Mock-up furnished with the equipments of kitchen and bathroom. The equipments of kitchen consist of sink and shelves to be capable of changing height. The equipments of bathroom consist of different height wash bowls, toilet stools, grab bars, and a bathtub. The study was accomplished by observing and measuring the use of the elderly.

  • PDF

실물 주거 시공을 통한 실내공기질에 영향을 미치는 주요 건축자재 및 시공방법에 관한 연구 (A Study on the Major Building Material and Construction Method Influencing to IAQ through Full-Scale House Construction)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.262-269
    • /
    • 2006
  • Formaldehyde and total volatile organic compounds (TVOC) from building materials have been known as main causes of IAQ problem in Newly-Constructed Multi-Family Houses. Because Multi-Family Houses are built in large quantities in a similar manner, inappropriate selection of building materials and method will detrimental affect IAQ. This research aims to identify major causes of Indoor Air Pollutants in Multi-Family Houses, by constructing Mock-Up & One-Room House. As a result, self leveling concrete, door, and furniture construction is a major cause of indoor formaldehyde increase, and tile bond is TVOC, and urethane water proof is Etylbenzene, and Xylene.

다세대.다가구주택 소유자 및 임차인과의 소집단 워크샵 패널을 통한 주택계획요소의 추출 (An Extraction of House Planning Elements by Small-Group Workshop Panel with Owners and Tenants of Multi-family House)

  • 이영선;김주석;이연숙
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.78-83
    • /
    • 2009
  • Since modern times, lack of housing had become more serious in the cities when going through urbanization process. As a countermeasure against the situation, multi-family houses raised its head at the end of 1980s. Regarding multi-family houses, which is mainly targeting low-income group, however, only quantitative supply has been focused with no enough research about space planning. For now that the supply of housing in the cities reached certain level, there is a need of planning multi-family house considering the demands of residents. Therefore, the purpose of this research is to identify and analyze the demands of owners and tenants of multi-family house in an improvement district of housing environment for housing improvement, and to extract house planning components. As a research methodology, small-group workshop panel using drawings and mock-up has been practiced to reach residents' concertized opinion. After dividing the residents group into 2 groups which include owners group(3 participants) and tenants group(3 participants), 3 times of workshops covering 2 days are conducted for each group. Actual-condition investigation of the participants' houses was ran side by side with workshop. As a result, difference in their point of view about the reasons and the direction of housing improvement was identified, on the other hand that there is similarity in their demands such as guaranteeing independency and privacy among households.

  • PDF

기술능력 발전의 시기별 특성: 포항제철 사례연구

  • 송성수
    • 기술혁신연구
    • /
    • 제10권1호
    • /
    • pp.174-200
    • /
    • 2002
  • Technological capabilities of POSCO (Pohang Iron & Steel Co.) have been developed through acquisition, catch-up, and generation stage. In 1970s standardized operation technologies were acquired based on Japan's technological cooperation. The prime route of technological acquisition was overseas training and operation technologies were articulated by mock and real operation. In 1980s POSCO focused to catch-up advanced technologies through in-house R&D activities. Technological informations were broadly accumulated, task force teams were constructed for important technological tasks, and the scope of technological innovation covered nearly all fields. In 1990s POSCO launched long-term projects based on the large-scale investment and challenged the new fronts of steel technologies. Frontier technologies such as smelting reduction and thin slab casting were early commercialized and new technological concepts were emerged. In conclusion, this article suggests some implications on the development of technological capabilities in Korea.

  • PDF

UHPC 외장패널을 활용한 비정형건축물 외장패널의 목업 시공사례에 대한 연구 - 부산 오페라 하우스 신축 공사 - (Study on Mock-up Construction Example of Free-Form Building Facade using External UHPC Panels - Focused on the Construction of Busan Opera House -)

  • 김태익;윤주용;최병걸;박용규;윤기원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.187-188
    • /
    • 2021
  • In the case of the Busan North Port, where the Busan Opera House is located, it is an environment exposed to various external deterioration factors such as frequent strong winds, seawater and salty winds, and an exterior material using UHPC (Ultra High Performance Concrete), a highly durable exterior material as a solution to this. Has been adopted. in this study, an economical production and construction direction was reviewed by applying UHPC to the exterior panels of atypical buildings that cannot cope with GFRC, metal, and glass, which are the main exterior finishing materials applied so far. When steel fibers are used, structural performance may be better than organic fibers, but due to environmental factors in Busan, corrosion due to exposure to steel fibers or problems with safety management after construction and completion may occur. Therefore, the site used the newly developed SACF fiber. Facade design of atypical buildings, which will increase in the future, is an important part, and the scope of use of UHPC panels is expected to increase in the future as design trends and demand for high durability increase.

  • PDF

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구 (Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds)

  • 조원화;임남기
    • 한국건축시공학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 2010
  • 본 연구에서는 전열해석 프로그램인 피지벨(PHYSIBEL)을 사용하여 블라인드 내장형 창호시스템의 일사차단성능 및 단열성능에 따른 에너지 성능을 평가하였다. 피지벨 해석시 창호별 구성 재료의 열적특성과 해석조건을 결정하기 위해서 Mock-up시험을 실시하였으며, 컴퓨터 시뮬레이션을 통한 결과를 바탕으로 공동주택 기준층 1개 세대(33평형)를 대상으로 연간에너지 소비특성, 연간전열량, 연간 냉난방 비용을 분석하였다. 실험결과, 연간전열량은 일반 창호시스템 대비 블라인드 내장형 창호시스템에서 블라인드를 올린 경우 냉방시 10%, 난방시 11% 절감할 수 있으며, 블라인드를 내린 경우 냉방시 25%, 난방시 30%정도를 절감할 수 있는 것으로 나타났다. 블라인드 내장형 창호시스템의 냉 난방 부하 절감량은 일반 창호시스템에 비해 냉방시 283.3KWh, 난방시 76.3KWh 로 냉 난방 에너지 절감효과는 단위세대당 359.6KWh 절감시킬 수 있는 것으로 나타났으며, 이것은 단위세대당 연간 에너지원단위(TOE) 약 0.078toe, 이산화탄소톤($tCO_2$) $0.16tCO_2$을 절감시킬 수 있어 온실가스 저감에도 유리할 것으로 판단된다. 또한, 블라인드 내장형 창호시스템의 냉 난방비용 절감액은 일반창호시스템과 비교하여 연간 냉방비용 10만원, 난방비용 5만원으로 연간 냉 난방 비용을 약 15만원 정도 절감시킬 수 있는 것으로 나타났다.

팬 설계 시스템에 의한 냉장고용 축류팬 개발 (Development of an axial flow fan for a refrigerator by in-house design system)

  • 최동규;최원석;박성관
    • 한국CDE학회논문집
    • /
    • 제2권2호
    • /
    • pp.85-92
    • /
    • 1997
  • An axial flow fan design system has been made by integrating the self-developed programs and I-DEAS. By using the system, an axial flow fan was designed, manufactured and verified through the wind tunnel experiments in coorperation with a refrigerator appliance division. It has been shown that the optimal design without the ambiguity of the design parameters can be possible by the three-dimensional flow simulations using a self-developed CID code, FANS-3D. (Flow Analysis code using Navier Stokes aguations in Three-Dimensional curvilinear coordinates). By virtue of the fluency of the data flow, an optimally designed fan which satisfies design conditions can be selected in a short time and less cost. The manufacturing processes of a Mock-up and an injection molding die have been automated through the self-made interface programs which connnect from the start to the end. It has been shown that the newly developed fan by this system has a superior performance characteristics to an existing fan.

  • PDF

마감공사후 경과시간에 따른 복합마감재의 VOCs/VVOCs 방출량과 실내농도에 관한 연구 (Emission rates of VOCs/VVOCs from multi-layers and their impacts on indoor air quality of Apartments)

  • 윤창현;권경우;박준석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.295-300
    • /
    • 2006
  • The purpose of this study is to evaluate the impacts of finishing materials' VVOCs and VOCs emission rates on indoor air quality of Apartment. VOCs emission rate of multi-layer finishing is predicted using the effective diffusion coefficient of each materials, and then the prediction is compared with Mock-up test and sample apartment house. From the results, the prediction of multi-layer finishing using the effective diffusion coefficient show good relation with the measured values.

  • PDF

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.