• Title/Summary/Keyword: Mobile 3D

Search Result 1,435, Processing Time 0.03 seconds

Studies on the Analysis of Benzo(a)pyrene and Its Metabolites on Biological Samples by Using High Performance Liquid Chromatography/Fluorescence Detection and Gas Chromatography/Mass Spectrometry

  • Lee, Won;Shin, Hye-Seung;Hong, Jee-Eun;Pyo, Hee-Soo;Kim, Yun-Je
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.559-565
    • /
    • 2003
  • An analytical method the determination of benzo(a)pyrene (BaP) and its hydroxylated metabolites, 1-hydroxybenzo(a)pyrene (1-OHBaP), 3-hydroxybenzo(a)pyrene (3-OHBaP), benzo(a)pyrene-4,5-dihydrodiol (4,5-diolBaP) and benzo(a)pyrene-7,8-dihydrodiol (7,8-diolBaP), in rat urine and plasma has been developed by HPLC/FLD and GC/MS. The derivatization with alkyl iodide was employed to improve the resolution and the detection of two mono hydroxylated metabolites, 1-OHBaP and 3-OHBaP, in LC and GC. BaP and its four metabolites in spiked urine were successfully separated by gradient elution on reverse phase ODS $C_{18}$ column (4.6 mm I.D., 100 mm length, particle size 5 ㎛) using a binary mixture of MeOH/H₂O (85/15, v/v) as mobile phase after ethylation at 90 ℃ for 10 min. The extraction recoveries of BaP and its metabolites in spiked samples with liquid-liquid extraction, which was better than solid phase extraction, were in the range of 90.3- 101.6% in n-hexane for urine and 95.7-106.3% in acetone for plasma, respectively. The calibration curves has shown good linearity with the correlation coefficients (R²) varying from 0.992 to 1.000 for urine and from 0.996 to 1.000 for plasma, respectively. The detection limits of all analytes were obtained in the range of 0.01-0.1 ng/mL for urine and 0.1-0.4 ng/mL for plasma, respectively. The metabolites of BaP were excreted as mono hydroxy and dihydrodiol forms after intraperitoneal injection of 20 mg/kg of BaP to rats. The total amounts of BaP and four metabolites excreted in dosed rat urine were 3.79 ng over the 0-96 hr period from adminstration and the excretional recovery was less than 0.065% of the injection amounts of BaP. The proposed method was successfully applied to the determination of BaP and its hydroxylated metabolites in rat urine and plasma for the pharmacokinetic studies.

A Mobile Landmarks Guide : Outdoor Augmented Reality based on LOD and Contextual Device (모바일 랜드마크 가이드 : LOD와 문맥적 장치 기반의 실외 증강현실)

  • Zhao, Bi-Cheng;Rosli, Ahmad Nurzid;Jang, Chol-Hee;Lee, Kee-Sung;Jo, Geun-Sik
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.1
    • /
    • pp.1-21
    • /
    • 2012
  • In recent years, mobile phone has experienced an extremely fast evolution. It is equipped with high-quality color displays, high resolution cameras, and real-time accelerated 3D graphics. In addition, some other features are includes GPS sensor and Digital Compass, etc. This evolution advent significantly helps the application developers to use the power of smart-phones, to create a rich environment that offers a wide range of services and exciting possibilities. To date mobile AR in outdoor research there are many popular location-based AR services, such Layar and Wikitude. These systems have big limitation the AR contents hardly overlaid on the real target. Another research is context-based AR services using image recognition and tracking. The AR contents are precisely overlaid on the real target. But the real-time performance is restricted by the retrieval time and hardly implement in large scale area. In our work, we exploit to combine advantages of location-based AR with context-based AR. The system can easily find out surrounding landmarks first and then do the recognition and tracking with them. The proposed system mainly consists of two major parts-landmark browsing module and annotation module. In landmark browsing module, user can view an augmented virtual information (information media), such as text, picture and video on their smart-phone viewfinder, when they pointing out their smart-phone to a certain building or landmark. For this, landmark recognition technique is applied in this work. SURF point-based features are used in the matching process due to their robustness. To ensure the image retrieval and matching processes is fast enough for real time tracking, we exploit the contextual device (GPS and digital compass) information. This is necessary to select the nearest and pointed orientation landmarks from the database. The queried image is only matched with this selected data. Therefore, the speed for matching will be significantly increased. Secondly is the annotation module. Instead of viewing only the augmented information media, user can create virtual annotation based on linked data. Having to know a full knowledge about the landmark, are not necessary required. They can simply look for the appropriate topic by searching it with a keyword in linked data. With this, it helps the system to find out target URI in order to generate correct AR contents. On the other hand, in order to recognize target landmarks, images of selected building or landmark are captured from different angle and distance. This procedure looks like a similar processing of building a connection between the real building and the virtual information existed in the Linked Open Data. In our experiments, search range in the database is reduced by clustering images into groups according to their coordinates. A Grid-base clustering method and user location information are used to restrict the retrieval range. Comparing the existed research using cluster and GPS information the retrieval time is around 70~80ms. Experiment results show our approach the retrieval time reduces to around 18~20ms in average. Therefore the totally processing time is reduced from 490~540ms to 438~480ms. The performance improvement will be more obvious when the database growing. It demonstrates the proposed system is efficient and robust in many cases.

Enhanced Production of Oleanolic Acid by the Elicitation in Oldenlandia diffusa Suspension Cell Cultures (백화사설초의 현탁세포배양에서 Elicitation에 의한 Oleanolic acid 생산성 증대)

  • Lee Yong-Il;Kim Dong-Il
    • KSBB Journal
    • /
    • v.19 no.6 s.89
    • /
    • pp.471-477
    • /
    • 2004
  • Oldenlandia diffusa is a Chinese medicinal herb with antitumor activity capable of suppressing the growth of some cancer cell lines. Oleanolic acid and ursolic acid are triterpenoid compounds that exist in Oldenlandia diffusa. Recently, these have been noted for anti-inflammatory, anti-cancer, and hepato-protective effects. Application of both plant growth regulators, 2,4-D and kinetin, was found to be essential for the initiation of callus and suspension cells. Leaf blades of Oldenlandia diffusa was transformed into callus on Schenk and Hildebrandt medium supplemented with 0.5 mg/L 2,4-D and 0.1 mg/L kinetin, while optimum initiation condition for suspension cells of Oldenlandia diffusa was determined to be 0.75 mg/L 2,4-D and 0.1 mg/L kinetin. Chromatographic separation of oleanolic acid from its derivatives was achieved using Rexchrom S5-100-ODS column. Analytical conditions for oleanolic acid were determined as follows: flow rate at 1.0 mL/min, UV length at 200 nm and mobile phase of $80\%$ acetonitrile and $20\%$ water. Production of secondary metabolites was found to be increased by the treatment with elicitors or signal transducers. The maximum production of oleanolic acid was 99.6 mg/L in cultures with 0.5 mM salicylic acid. It is 1.74 times higher than that of control.

Radiotherapy for Oral Cavity Cancer (구강암의 방사선치료)

  • Shim Jae Won;Yoo Seong Yul;Koh Kyoung Hwan;Cho Chul Koo;Yun Hyong Geun;Kim Jae Young
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.267-275
    • /
    • 1993
  • Eighty five patients of oral cavity cancer, treated with radiation at the Department of Therapeutic Radiology, Korea Cancer Center Hospital, during the period from March 1985 to September 1990 were analyzed retrospectively. Among 85 patients, 37 patients were treated with radiation only and 48 patients were treated with radiation following surgery. And 70 patients received external irradiation only by $^{60}Co$ with or without electron, the others were 7 patients for external irradiation plus interstitial implantation and 8 patients for external irradiation plus oral cone electron therapy. Primary sites were mobile tongue for 40 patients, mouth floor for 17 patients, palate for 12 patients, gingiva including retromolar trigone for 10 patients, buccal mucosa for 5 patients, and lip for 1 patient. According to pathologic classification, squamous cell carcinoma was the most common (77 patients). According to AJC TNM stage, stage I + II were 28 patients and stage III+IV were 57 patients. Acturial overall survival rate at 3 years was $43.9\%,$ 3 year survival rates were $60.9\%$ for stage I + II, and $23.1\%$ for stage III+IV, respectively. As a prognostic factor, primary T stage was a significant factor (p<0.01). The others, age, location, lymph node metastasis, surgery, radiation dose, and cell differentiation were not statistically significant. Among those factors, radiation plus surgery was more effective than radiation only in T3+T4 or in any N stage although it was not statistically sufficient (p<0.1). From those results, it was conclusive that definitive radiotherapy was more effective than surgery especially In the view of pertainig of anatomical integrity and function in early stage, and radiation plus surgery was considered to be better therapeutic tool in advanced stage.

  • PDF

Study on the Passive IMD Improvement of RF DIN Connectors (RF DIN Connector의 Passive IMD 개선에 관한 연구)

  • Ko, Yun-Sun;Chung, Jae-Pil;Oh, Chang-Heon;Shin, Dong-Uk
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.3
    • /
    • pp.195-202
    • /
    • 2002
  • Recently, as the range of mobile communication services is extended, the interference between adjacent base-stations is increased. Nowdays, one of the important factors causing interference is IMD (Inter-Modulation Distortion) problems. Not only active IMD but also passive IMD effects must be considered to design a CDMA system. In this study, we design and implement 7/16" DIN connectors which have a various intensity of surface illumination, thickness and quality of plating material to analyze the effects of PIMD. And propose the methods for improving the PIMD characteristics: First, it is more profitable to use the metal which has good intensity of surface illumination where most of all electric currents passes through it. Secondly, we should plate metals more than $5{\mu}m$ for RF energy enough to propagate in a medium. Thirdly, it is necessary to select a metal having high conductivity and specific heat to protect the aging phenomenon of plate material. And it is required to develop a new plating material to replace the current materials, such as the alloy of three components for cost reduction. We have to know that the plate which has intensity of surface illumination 6 S and the thickness of plating material $5{\mu}m$ satisfy the domestic PIMD specification (KTF) -150 dBc, regardless of the plate material in case of 7/16" DIN connector.

  • PDF

Development of unified communication for marine VoIP service (해상 VoIP 서비스를 위한 통합 커뮤니케이션 기술 개발)

  • Kang, Nam-seon;Yim, Geun-wan;Lee, Seong-haeng;Kim, Sang-yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.744-753
    • /
    • 2015
  • This paper presents the results of research on developing marine unified communications to provide VoIP service based on marine satellites. With the recent popularity of smart-phones and other mobile devices, the demand for Internet-based wired and wireless unified technology has been growing in marine environments, and increasing interest is being directed to VoIP products and service models with high price competitiveness and the ability to deliver a variety of services. In this regard, this research designed three instruments, developed their unit modules, and verified their performances. These three instruments included the following: (1) a marine VoIP module equipped with an analogue gateway that can be linked to the existing devices used in vessels, which is more than 80% smaller than that of a land system; (2) a text/voice/video engine for marine satellite communications that runs on technology that minimizes communication data usage, which is a core technology for a marine VoIP service; and (3) a unified communication service that can support multilateral cloud-based message conversations, telephone number-based call functions, and voice/video calling between a private space in a ship and shore.

HPLC analytical method validation of Aralia elata extract as a functional ingredients (두릅 추출물의 기능성 원료 표준화를 위한 HPLC 분석법 검증)

  • Ahn, Eun-Mi;Choi, Song-Am;Choi, Ji-Young
    • Food Science and Preservation
    • /
    • v.24 no.6
    • /
    • pp.795-801
    • /
    • 2017
  • Aralia elata Seemann (AE) has long been used as a folk medicine for the treatment of various diseases including diabetes mellitus, anti-arthritic, and anti-gastric ulcer agent in Korea, Japan, and China. This study was performed to establish a simple and reliable HPLC/UV analytical method for determination of most active anti-hypertensive compound, a 3-O-${\alpha}$-L-rhamnopyranosyl($1{\rightarrow}$2)-${\alpha}$-L-arabinopyranosyl hederagenin 28-O-${\beta}$-D-xylopyranosyl($1{\rightarrow}6$)-${\beta}$-D-glucopyranosylester (HE) for the standardization of the shoot extract of AE as a health functional food ingredient. The quantitative analytical method of HE was optimized by HPLC analysis using reverse-phase C18 column at $40^{\circ}C$ with $H_2O$ and acetonitrile (70:30, v/v) as an isocratic mobile phase at a flow rate of 1.0 mL/min and detection wavelength of UV 205 nm. This HPLC/UV analytical method showed good specificity and high linearity in the tested range of 0.03125-2.0mg/ml with excellent coefficient of determination ($R^2$) of 0.9999. The limit of detection and limit of quantification were $12.0{\mu}g/mL$ and $36.5{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 0.2% and 0.1%, respectively. These results indicate that the established HPLC/UV analytical method is very simple, specific, precise, accurate, and reproducible and thus can be useful for the quantitative analysis of HE as a functional anti-hypertensive compound in AE extract.

Multiple Reference Network Data Processing Algorithms for High Precision of Long-Baseline Kinematic Positioning by GPS/INS Integration (GPS/INS 통합에 의한 고정밀 장기선 동적 측위를 위한 다중 기준국 네트워크 데이터 처리 알고리즘)

  • Lee, Hung-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.135-143
    • /
    • 2009
  • Integrating the Global Positioning System (GPS) and Inertial Navigation System (INS) sensor technologies using the precise GPS Carrier phase measurements is a methodology that has been widely applied in those application fields requiring accurate and reliable positioning and attitude determination; ranging from 'kinematic geodesy', to mobile mapping and imaging, to precise navigation. However, such integrated system may not fulfil the demanding performance requirements when the baseline length between reference and mobil user GPS receiver is grater than a few tens of kilometers. This is because their positioning/attitude determination is still very dependent on the errors of the GPS observations, so-called "baseline dependent errors". This limitation can be remedied by the integration of GPS and INS sensors, using multiple reference stations. Hence, in order to derive the GPS distance dependent errors, this research proposes measurement processing algorithms for multiple reference stations, such as a reference station ambiguity resolution procedure using linear combination techniques, a error estimation based on Kalman filter and a error interpolation. In addition, all the algorithms are evaluated by processing real observations and results are summarized in this paper.

A Study on Developing Web based Logistic Information System(KT-Logis) (웹 기반 통합물류정보시스템(KT-Logis) 개발에 관한 연구)

  • 오상호;김태준
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2001.11b
    • /
    • pp.125-141
    • /
    • 2001
  • In this paper, the current problems of logistics industry in Korea and their possible solutions were discussed. With Korea Telecoms KT-Logis, the supplier and demander of logistics service would not have to invest large sum of money into their computer system. All they need is just a computer with internet connected. What KT-Logis influence on the logistics industry are the following; 1. Many logistics service supplier and demander can do the business on the web with one computer system. 2. This web based computer system does not only work on the office but also apply on the field worker such as delivery personnel or even the forwarder with mobile phone. 3. KT-Logis is an integrated system which cover the broad arrange of logistics management from truck management to customer relations management. 4. Finally, KT-Logis is web based systems which suits for current e-business and mobile environment. In future, more studies should be done to develop more progressive integrated logistics information systems with enterprise resource planning(ERP) and supply chain management(SCM).

  • PDF

Determination of 10${\alpha}$-Methoxy-9,10-dihydrolysergol (MDL), Main Metabolite of Nicergoline, in Human Plasma by HPLC-MS and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC-MS를 이용한 생체시료 중 니세르골린의 주대사체인 10${\alpha}$-Methoxy-9,10-dihydrolysergol(MDL)의 분석 및 이를 이용한 한국인 성인 남성에 대한 생체이용률 응용)

  • Lim, Hyon-Kyun;Yoo, Sun-Dong;Kim, Kyeong-Ho;Han, Sang-Beom;Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • A simple and sensitive HPLC-MS method for quantitation of 10${\alpha}$-methoxy-9,10-dihydrolysergol (MDL), the main metabolite of nicergoline, in human plasma was developed and the bioavailability parameters of MDL was assessed in Korean healthy male volunteers. Clomipramine was used as an internal standard. MDL and internal standard in plasma sample were extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 10 mM ammonium acetate-acetonitrile (10 : 90, v/v). The reconstituted samples were injected into a Zorbax SB-C8 column (2.1${\times}$150 mm,5 ${\mu}$m) at a flow-rate of 0.3 ml/min. Using MS with selected ion monitoring (SIM) mode, MDL and clomipramine were detected without severe interference from human plasma matrix. MDL produced a protonated molecular ion ([M+H]$^+$) at m/z 287. Internal standard produced a protonated molecular ion ([M+H]$^+$) at m/z 315. A linear relationship for MDL was found in the range of 2.5${\sim}$100 ng/ml. The lower limit of quantitation (LLOQ) was 2.5 ng/ml with acceptable precision and accuracy. The intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 30 mg of nicergoline were revealed as follows: AUC$_t$ 321.1${\pm}$64.5 ng${\cdot}$hr/ml, C$_{max}$, 51.2${\pm}$25.3 ng/ml, T$_{max}$ 3.6${\pm}$1.5 hr, K$_{el}$ 0.12${\pm}$0.07 hr$^{-1}$ and t$_{1/2}$ 7.6${\pm}$3.4 hr. Inter subject variations and race differences were shown in comparison with the published data in the literature.