• Title/Summary/Keyword: Mixed Wastewater

Search Result 301, Processing Time 0.023 seconds

Polyvinyl Alcohol 분해 공생 균주에 의한 염색 폐수 중의 PVA 제거

  • Kim, Chul Ki;Choi, Yong-Jin;Lee, Chul-Woo;Rim, Yeon-Taek;Ryu, Jae-Keun
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.1
    • /
    • pp.89-95
    • /
    • 1997
  • The current processer of the textile wastewater treatment are mostly consisted of a combination of a physico-chemical and a biological treatment. The overall efficiency of these processes is, however, assessed to be fairly low. It is even worse during the summer season when temperature of the wastewater rises above 40$\circ $C. Therefore, a feasible process of the textile wastewater treatment which can work efficiently at higher temperatures was investigated in this work. We used a bench scale reactor consisted of one 4 liter anaerobic and one 8 liter aerobic tank, and the thermophilic symbiotic PVA degraders, Pasteruella hemolytica KMG1 and Pseudomonas sp. KMG6 that had been isolated in our laboratory. In the preliminary flask experiments, we observed that the thermophilic symbiotic PVA degraders could not grow in the wastewater substrate. Then, we isolated the mutant strains by acclimating the KMG1and KMG6 strains to the wastewater medium. The mutant symbionts (KMG1-1 and KMG6-1) were isolated through 6 times successive transfers into the fresh wastewater medium after 5 days culture for each. The mutant strains obtained grew well in the mixed medium composed of 75% wastewater and 25% synthetic medium, and supplemented with 0.5% PVA as a sole carbon source. During the culture for 14 days at pH 7.0 and 40$\CIRC $C, the bacteria assimilated about 89% of the added PVA. The symbionts degraded equally well all the PVA substrates of different molecular weight (nd=500~30000). In contrast to the flask experiments, in the reactor system the mutant strains showed very low levels of the PVA and COD removal rates. However, the new reactor system with an additional aerobic tank attained 82% removal rate of COD, 94% of PVA degradation and 71% of color index under the conditions of 5% inoculm on the tank 2, incubation temperature of 40$\circ $C, dissolved oxygen level of 2~3 mg/l and retention time of 30 hours. This result ensures that the process described above could be an efficient and feasible treatment for the PVA contained textile wastewater at higher temperatures.

  • PDF

Effects of the Characteristics of Influent Wastewater on Removal Efficiencies for Organic Matters in Wastewater Treatment Plants (하·폐수 처리시설 내 유입수 특성이 유기물 처리효율에 미치는 영향)

  • Lee, Tae-Hwan;Park, Min-Hye;Lee, Bomi;Hur, Jin;Yang, Heejeoug
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.674-681
    • /
    • 2009
  • Characteristics of organic matters (OM) in wastewater and the removal efficiencies were investigated using the influent and the effluent samples collected from 21 wastewater treatment plants. The OM characteristics investigated included biodegradability, humic content, specific UV absorbance (SUVA), the distribution percentage of refractory OM (R-OM), and synchronous fluorescence spectra. The types of wastewater (sewage, livestock waste/night soils, industrial waste) were easily distinguished by comparing the synchronous fluorescence spectra of the influent wastewater. The prominent peak of protein-like fluorescence (PLF) was observed for livestock waste/night soils whereas sewage exhibited a unique fluorescence peak at a wavelength of 370 nm. Irrespective of the wastewater types, the distribution percentage of R-OM increased from the influent to the effluent. Livestock waste/night soils showed the highest removal efficiency among all the three types of wastewater. There was no statistical difference of the removal efficiency between a traditional activated sludge and biological advanced treatment processes. Removal efficiency based on dissolved organic carbon DOC presented good correlations with the distribution percentage of R-OM and fulvic-like fluorescence (FLF) of the influent. The prediction for DOC removal efficiency was improved by using multiple regression analyses based on some selected OM characteristics and mixed liquid suspended solid (MLSS).

Wastewater from Instant Noodle Factory as the Whole Nutrients Source for the Microalga Scenedesmus sp. Cultivation

  • Whangchenchom, Worawit;Chiemchaisri, Wilai;Tapaneeyaworawong, Paveena;Powtongsook, Sorawit
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.283-287
    • /
    • 2014
  • Cultivation of microalgae using wastewater exhibits several advantages such as nutrient removal and the production of high valuable products such as lipid and pigments. With this study, two types of wastewater from instant noodle factory; mixed liquor suspended solids (MLSS) and effluents after sedimentation tank were investigated for green microalga Scenedesmus sp. cultivation under laboratory condition. Optimal wastewater dilution percentage was evaluated in 24 wells microplate. MLSS and effluent without dilution showed the highest specific growth rate (${\mu}$) of $1.63{\pm}0.11day^{-1}$ and $1.57{\pm}0.16day^{-1}$, respectively, in which they were significantly (p < 0.05) higher than Scenedesmus sp. grown in BG11 medium ($1.08{\pm}0.14day^{-1}$). Ten days experiment was also conducted using 2000 ml Duran bottle as culture vessel under continuous light at approximately 5000 lux intensity and continuous aeration. It was found that maximum biomass density of microalgae cultivated in MLSS and effluent were $344.16{\pm}105.60mg/L$ and $512.89{\pm}86.93mg/L$ respectively and there was no significant (p < 0.05) difference on growth to control (BG11 medium). Moreover, cultivation microalgae in wastewater could reduce COD in wastewater by 39.89%-73.37%. Therefore, cultivation of Scenedesmus sp. in wastewater from instant noodle factory can yield microalgae biomass production and wastewater reclamation using photobioreactor simultaneously.

Effects of Volatile Solid Concentration and Mixing Ratio on Hydrogen Production by Co-Digesting Molasses Wastewater and Sewage Sludge

  • Lee, Jung-Yeol;Wee, Daehyun;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.11
    • /
    • pp.1542-1550
    • /
    • 2014
  • Co-digesting molasses wastewater and sewage sludge was evaluated for hydrogen production by response surface methodology (RSM). Batch experiments in accordance with various dilution ratios (40- to 5-fold) and waste mixing composition ratios (100:0, 80:20, 60:40, 40:60, 20:80, and 0:100, on a volume basis) were conducted. Volatile solid (VS) concentration strongly affected the hydrogen production rate and yield compared with the waste mixing ratio. The specific hydrogen production rate was predicted to be optimal when the VS concentration ranged from 10 to 12 g/l at all the mixing ratios of molasses wastewater and sewage sludge. A hydrogen yield of over 50 ml $H_2/gVS_{removed}$ was obtained from mixed waste of 10% sewage sludge and 10 g/l VS (about 10-fold dilution ratio). The optimal chemical oxygen demand/total nitrogen ratio for co-digesting molasses wastewater and sewage sludge was between 250 and 300 with a hydrogen yield above 20 ml $H_2/gVS_{removed}$.

A Study on the Removal of Pollutants from Wastewater by Aquatic Macrophytes (수생식물에 의한 폐수의 오염물질제거에 관한 연구)

  • Cho, Hae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.941-946
    • /
    • 2012
  • Macrophyte plays an important role in purification of wastewater. They have capacity to improve the water quality by absorbing nutrients, with their effective root system. In this study, removal of nutrient as well as organic matter was observed by some important macrophytes i.e. Pistia stratoites, Hydrocharis dubia and Salvinia sp. indepe ndently as well as in mixed culture under the laboratory condition. The highest total nitrogen removal was observed for Pistia stratoites (86.47%) in monoculture and Salvinia sp. + P. stratoites (76.11%) in mixed culture system. Corresponding figures for total phosphorous were observed for P. stratoites (75.60%) in monoculture and Salvinia sp. + P. stratoites (71.11%) in mixed culture system. Similar result was observed for ammonia removal in both systems. Additionally, P. stratoites showed the highest removal of organic matter, in monoculture system (68.46%) where as Salvinia sp. + P. stratoites showed the highest removal of organic matter in mixed culture system (82.73 %).

Initial Operating Condition of Membrane Bioreactor with PVDF Hollow Fiber and Permeate Reuse (PVDF 중공사막을 이용한 막생물반응기의 초기 운전조건 설정 및 여과수 재활용)

  • Shin, Choon-Hwan;Kang, Dong-Hyo;Park, Hae-Sik;Cho, Hyun-Kil
    • Clean Technology
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • In this paper, 4 bundle modules of PVDF hollow fiber membrane from Woori Tech company (Korea) were manufactured in a treatment capacity of 10 ton/day. A membrane bioreactor (MBR) pilot plant was installed at Sooyoung Wastewater Treatment Plant in Busan. An alternating aeration process was selected to avoid the concentration profile of suspended solid (SS) in the MBR. For stable operation, raw wastewater with mixed liquor suspended solid (MLSS) of about 1,000 ppm, which was in-flowed from the aeration tank of the wastewater treatment plant, was fed and filtered through the pilot plant. Subsequently the pilot plant were washed three times with washing water: once with ethanol solution, once with a solution of 5% NaOCl, and finally with washing water. After the chemical washing, the remaining water in the MBR was fed into the pilot plant. As a result, the SS removal efficiency was found to be more than 99.9%. The amount of filtrate with the aeration tank influent decreased by 16%, compared with that from the initial conditions, giving rise to 30% increase in the suction pressure. These results were used to set up continuous operation conditions. The results from the continuous operation with influent MLSS of 1,900 mg/L showed that the SS removal efficiency was about 99.99% and that the amount of filtrate and the suction pressure were $42{\sim}52L/m^2$ and 16~20 cmHg, respectively, indicating stable operation of the pilot plant. However, for the reuse of wastewater, methods need to be sought to avoid growth of algae which affects the SS removal efficiency at inlet and outlet of the permeate tank.

Effect of the Sewage and Wastewater Plant Effluent on the Algal Growth Potential in the Nakdong River Basin (낙동강 수계 하.폐수 처리시설의 방류수가 조류 성장 잠재력에 미치는 영향)

  • Seo,Jeong-Gwan;Lee,Jae-Jeong;Yang,Sang-Yong;Jeong,Ik-Gyo
    • ALGAE
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2003
  • Effect of the effluent of the sewage and wastewater plants on the algal growth was investigated from the 19 plants located in the Nakdong river basin. Most of the samples showed high values of the algal growth potential (AGP) when they were mixed with natural river water at 20% of final concentration. At 20% of the mixing ratio, the mixed effluents of sewage and wastewater showed 3.5 and 1.8 times higher AGP than those of the natural river water. The higher AGP values are attributable to the high contents of phosphorus and ammonium in the effluent. The mixing ratio of effluents of the discharge/river flow was highest in the Kumho River (42.8%) followed by the middle of Nakdong River (22.7%), Kam Stream (13.9%), Byungsung Stream (13.3%), Yangsan Stream (7.9%), and Young River (5.4%). Comparison of the trophic state of the effluents with natural river water indicated that the effluents showed higher trophic values than natural water. Concentrations of total phosphorus, total nitrogen and conductivity in the effluents were 12.3, 4.9 and 5.3 times higher than the those found in natural river water respectively. The AGP values were highly related with the trophicity of the water especially on the concentrations of phosphate and ammonium. Toxicities of the treated sewage water, wastewater and livestock waste water tested by the luminescent bacteria, Vibrio fischerii were generally low.

Elution characteristics of lime-based granular alkaline material and applicability of phosphorus crystallization processes (석회계 입상알칼리재의 용출특성과 이를 이용한 인 결정화공정의 적용성)

  • Chang, Hyang-Youn;Park, Na-Ri;Jang, Yeo-Ju;Ahn, Kwang-Ho;Lim, Hyun-Man;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.577-586
    • /
    • 2017
  • One of the major sources causing eutrophication and algal blooms of lakes or streams is phosphorus which comes from point and nonpoint pollution sources. HAP (hydroxyapatite) crystallization using granular alkaline materials can achieve the decrease of phosphorus load from wastewater treatment plants and nonpoint pollution control facilities. In order to induce HAP crystal formation, continuous supply of calcium and hydroxyl ions is required. In this research, considering HAP crystallization, several types of lime-based granular alkaline materials were prepared, and the elution characteristics of calcium and hydroxyl ions of each were analyzed. Also, column tests were performed to verify phosphorus removal efficiencies of granular alkaline materials. Material_1 (gypsum+cement mixed material) achieved the highest pH values in the column tests consistently, also, Material_2 (gypsum+slag mixed material) and Material_3 (calcined limestone material) achieved over pH 9.0 for 240 hours (10 days) and proved the efficiencies of long-term ion supplier for HAP crystallization. In the column tests using Material_3, considerable pH increase and phosphorus removal were carried out according to each linear velocity and filtration depth. T-P removal efficiencies were 87.0, 84.0, 68.0% and those of PO4-P 100.0, 97.0, 80.0% for linear velocity of 1.0, 2.5, 5.0 m/hr respectively. Based on the column test results, the applicability of phosphorus removal processes for small-scale wastewater treatment plants and nonpoint pollution control facilities was found out.

Characterization of TCE-Degrading Bacteria and Their Application to Wastewater Treatment

  • Lee, Wan-Seok;Park, Chan-Sun;Kim, Jang-Eok;Yoon, Byung-Dae;Oh, Hee-Mock
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.4
    • /
    • pp.569-575
    • /
    • 2002
  • Two bacterial strains capable of degrading trichloroethylene (TCE), isolated form soils contaminated with various chlorinated alkenes, were identified as Alcaligenes odorous N6 and Nocardia sp. Hl7. In addition, four KCTC strains, including three strains of Pseudomonas putida and one strain of Sphingomonas chlorophenolica, exhibited an ability to degrade toluene. A. odorans N6 and Nocardia sp. H17 degraded 84% of the initial amount of TCE in a basal salts medium (BSM), containing 0.2 mM TCE as the sole source of carbon and energy, in a day. The optimal pH for growth was within a range of 7.0-8.0. A mixed culture of the four toluene-degrading isolates degraded 95% of 0.2 mM TCE with 1.5 mM toluene as an inducer, whereas no TCE was degraded by the same mixture without an inducer. When a mixed culture of all 6 isolates was used, the degradation efficiency of 0.2 mM TCE was 72% without an inducer, in a day, and 82% with toluene as an inducer. In a continuous treatment, 1,000 mg/1 of TCE in an artificial wastewater was completely removed within 18 h when an activated sludge was used along with the microbial mixture, which was 27 h laster than when only an activated sludge was used. Accordingly, it would appear that such a microbial mixture could be effectively applied to the biological treatment of wastewater containing TCE with or without an inducer.

Dewaterability of the Municipal Wastewater Sludge Mixed with Livestock Sludge (축산 슬러지와 혼합된 도시하수슬러지의 탈수성)

  • Jo, Ji-Min;Choi, Min-Seok;Han, Young-Gyu;Kim, Yeong-Kwan
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, a series of experiment was carried to improve dewaterability of the sludge produced in a treatment plant, located in Hongcheon, Gangwondo, which has been treating municipal wastewater and livestock wastewater. Optimum sludge mixing ratio and the amount of sludge conditioner were determined. As sludge conditioners, alum and ferric salt were selected and tested. For the measurement of sludge dewaterability, capillary suction time(CST) and the specific resistance were measured, The specific resistance was detemined by running a series of Buchner Funnel Test. Mixing the two sludges at a 50:50 ratio with the addition of 20 mL alum gave the best results in terms of dewaterability. The moisture content decreased by 2% at this condition.

  • PDF