• Title/Summary/Keyword: Mixed Gases

Search Result 229, Processing Time 0.028 seconds

Lightning Impulse Breakdown Characteristics of SF6-based Mixture Gases (SF6계 혼합가스의 뇌임펄스 절연파괴특성)

  • Seo, Ho-Joon;Rhie, Dong-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.675-681
    • /
    • 2005
  • $SF_6$ is widely used as gas insulation medium because of having excellent dielectric and arc-quenching properties. However the use of it is getting to be suppressed from the viewpoint of mitigating global warming. For the development of environmentally-benign electric power equipment and system, novel gases or mixture gases are strongly required as the substitute of $SF_6$ gas. In this study the authors constructed an experimental system to investigate insulation properties of the mixed gases composed of negative $gas(SF_6)$ and electron deceleration gases$(N_2\;and\;CO_2)$. Breakdown and prebreakdown characteristics of $SF_6/N_2/CO_2$ mixture gases were investigated using the above mentioned system for different rates and gas pressures.

Adsorption Characteristics of $CH_4/CO_2$ Mixed Gases on Activated Carbon Fibers (활성탄소섬유상에서 CH4/CO2 혼합가스의 흡착 특성)

  • Moon, Seung-Hyun;Shim, Jae-Woon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.655-662
    • /
    • 2004
  • An adsorption process to recover the pure $CH_4\;and\;CO_2$ from its mixture was examined. In this study, activated carbon fibers were used as a selective adsorbent. The activated carbon fibers has 78~94% micropore volume and 10.5~20.3${\AA}$ narrow pore size, and showed high adsorption rate and the good selectivity for $CO_2$ under the ambient pressure. The ACF with high surface area showed short mass transfer zone and long breakthrough time and, its adsorption capacity depended on the microporosity. Compared with single component adsorption, the amount adsorbed $CO_2$ on ACF increased by the roll-up of $CH_4$ in mixed gases. The adsorption selectivity increased as now rate and $CO_2$ concentration of mixed gases increased, showing 5.2 selectivity for 75% $CO_2$ concentration.

The Analysis of DC Plasmas Characteristics on SFSF6 and N2 Mixture Gases (SF6/N2 혼합기체의 DC 플라즈마 특성 분석)

  • So, Soon-Youl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1485-1490
    • /
    • 2014
  • $SF_6$ gas has been used for power transformers or gas insulated switchgears, because it has the superior insulation property and the stable structure chemically. It has been, however, one of global warming gases and required to reduce the its amount. Some papers have reported that its amount could be reduced by mixing with other gases, such as $N_2$, $CF_4$, $CO_2$ and $C_4F_8$ and their mixture gases would cause the synergy effect. In this paper, we investigated the characteristics of DC plasmas on $SF_6$ mixture gases with $N_2$ at atmospheric pressure. $N_2$ gas is one of cheap gases and has been reported to show the synergy effect with mixing $SF_6$ gas, even though $N_2$ plasmas have electron-positive characteristics. 38 kinds of $SF_6/N_2$ plasma particles, which consisted of an electron, two positive ions, five negative ions, 30 excitation and vibration particles, were considered in a one dimensional fluid simulation model with capacitively coupled plasma chamber. The results showed that the joule heating of $SF_6/N_2$ plasmas was mainly caused by positive ions, on the other hand electrons acted on holding the $SF_6/N_2$ plasmas stably. The joule heating was strongly generated near the electrodes, which caused the increase of neutral gas temperature within the chamber. The more $N_2$ mixed-ratio increased, the less joule heating was. And the power consumptions by electron and positive ions increased with the increase of $N_2$ mixed-ratio.

Field emission characteristics of carbon nanotubes under residual gases

  • Lee, Han-Sung;Jang, Eun-Soo;Goak, Jeung-Choon;Choi, Young-Chul;Lee, Nae-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1539-1540
    • /
    • 2008
  • The field degradation of carbon nanotube field emitters in diode emission at constant current was demonstrated to be highly dependent upon the presence of residual gases at partial pressures. Upon exposure to a higher pressure of oxygen containing gases, for example, $O_2$ and CO increased the voltage. Those gases give rise to chemical etching to CNTs emitters. On the contrary, $CH_4$ affected the emission properties in the opposite direction as decreasing the voltage which was probably attributed to the introduction of adsorbate tunneling states. The mixed gas may cause a combined effect of both adsorbate tunneling states and CNT etching.

  • PDF

Technical study on quantitative analysis of the toxic gas concerning the combustion property of interior materials of railway car (철도차량용 내장 재료의 연소특성을 고려한 유해가스 정량분석 기법연구)

  • Park, Ji-Young;Lee, Cheul-Kyu;Lee, Duck-Hee;Jung, Woo-Sung;Chung, Hoe-Il
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1114-1118
    • /
    • 2008
  • In previous fire accident of railway car, the fatality was relatively high by toxic gas poisoning cause of closed space. So the necessity of quantifying toxic gas in combustion gas was recognized and then, FT-IR spectroscopy was introduced for real-time analysis of mixed gases and stimulated analysis of the concentration of several gases. Thus, in this study, absorption bands using FT-IR were obtained by each component of combustion gases for interior materials of railway car such as flooring materials and moquette seat. And then the sample spectra were compared with the spectra of NO, $NO_2$, $SO_2$ reference gases, we could obtain some identical peaks of them.

  • PDF

Effect of Mixed Gases on Decomposition Characteristic of CF4 by Non-Thermal Plasma (비열플라즈마를 이용한 CF4 분해에 미치는 혼합가스의 영향)

  • 박재윤;정장근;김종석;임근희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.543-550
    • /
    • 2002
  • In this paper, the $CF_4$ decomposition rate and by-product were investigated for two simulated plasma reactors which are metal particle reactor and spiral wire reactors as a function of mixed gases. The $CF_4$ decomposition rate by plasma reactor with metal particle electrode had a gain of 20~25% over that by plasma reactor with spiral wire electrode. The $CF_4$ decomposition efficiency increases with increasing applied voltage up to the critical voltage for spark formation. The $CF_4$ decomposition efficiency of metal particle reactor was about 80% at AC 24kV. The $CF_4$ decomposition rate used Ar-$N_2$ as base gas was the highest among three base gases of $N_2$, $Ar-N_2$, air. The by-products of the $N_2$, $N_2Ar$ base as were similar, but in case of air base they were different.

Trends on the Research for Alternatives of $SF_6$ Gas ($SF_6$ 대체가스 연구동향)

  • Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1403-1406
    • /
    • 2002
  • Environmental impact of human activities has become a great concern in most of the countries world-wide, and for years. It has recently focused on potential climate changes due to the increase of green house gases content in the atmosphere. One of these gases is $SF_6$, which is an essential material in electrical applications having excellent dielectric and arc-quenching properties. Though the actual contribution of $SF_6$ to global warming is negligible at present, the control of $SF_6$ emissions seems to be nevertheless imperative. Actually, it is listed in the Kyoto protocol that emissions should not only be duly reported but also the electrical industry which is now the major user of this gas must be able to show that it is possible to use this gas and at the same time preserve the environment. For the development of environmentally-benign electric power equipment and systems, novel gases or gas mixtures are strongly required as the alternatives of $SF_6$ gas. Until now, most research work is focused on the $SF_6/N_2$ mixed gas which is suitable for application in the electrical apparatus with slightly non-uniform fields. Recently, $SF_6/CO_2$ mixed gas also is expected to be promising as a $SF_6$ alternative, especially in highly non-uniform fields and in a gas-impregnated film insulation system. Including these results, the author reviews the research trend or reducing the environmental impact of $SF_6$ gas in this paper.

  • PDF

Variations of Equilibrium Adsorption Capacities According to Type and Mixing Fraction of Binary Mixed Gas on Activated Carbon Fixed-bed (활성탄 고정층에서 2성분 혼합가스의 종류와 혼합 분율에 따른 포화 흡착량의 변화)

  • Kim, Hyo-Won;Lee, Song-Woo;Lee, Min-Gyu;Cheon, Jae-Kee
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1197-1202
    • /
    • 2007
  • Adsorption experiments of binary mixed gases composed of acetone/methylethylketone (MEK), MEK/benzene, MEK/toluene, and benzene/toluene were carried out on activated carbon fixed-bed. The variations of equilibrium adsorption capacity according to type and fraction of binary gas were investigated. In case of binary gases composed of acetone/MEK and benzene/toluene, equilibrium adsorption capacities of MEK and toluene were increased according to the increase of fraction of MEK and toluene, but equilibrium adsorption capacities of acetone and benzene were decreased. In case of binary gases composed of MEK/benzene and MEK/toluene, equilibrium adsorption capacities of benzene and toluene were increased according to the increase of fraction of benzene and toluene, but equilibrium adsorption capacities of MEK was decreased.

Industrial application of gross error estimation and data reconciliation to byproduction gases in iron and steel making plants

  • Yi, Heui-Seok;Hakchul Shin;Kim, Jeong-Hwan;Chonghun Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.69.2-69
    • /
    • 2002
  • Process measurements contain random and gross errors and the size estimation of gross errors is required for production accounting. Mixed integer programming technique had been applied to identify and estimate the gross errors simultaneously. However, the compensate model based on mixed integer programming used all measured variables or spanning tree as gross error candidates. This makes gross error estimation problem combinatorial or computationally expensive. Mixed integer programming with test statistics is proposed for computationally inexpensive gross error identification /estimation. The gross error candidates are identified by measurement test and the set of gross error candidates are...

  • PDF

Emission Characteristics of Discharge Tube with Mixed Gases

  • Jo, Ju-Ung;Park, Yong-Sung;Lee, Jong-Chan;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.136-139
    • /
    • 2003
  • The positive column of a discharge tube filled with a mixture of mercury-xenon has a tendency to become contracted at room temperature. However, once the tube temperature is raised over 50 [$^{\circ}C$], the positive column changes from a contracted state to a diffused state. The xenon emission is stronger in the contracted positive column than in the diffused column. Alternatively, the mercury emission is more intense in the diffused positive column, and the luminance of the phosphor coating on the inner surface of the tube is higher than that in the contracted positive column. Moreover, higher luminance can be obtained by increasing the xenon pressure.