• 제목/요약/키워드: Mixed Flow

검색결과 1,291건 처리시간 0.031초

쉴리렌 간섭계에 의한 사각덕트내 후향계단후 유동에서의 혼합대류 전열에 관한 연구 (A Study on Mixed Convection Heat Transfer in Duct Flow behind a Backward-Facing Step by Using Schlieren Interferometer)

  • 백병준;박복춘;김진택
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 1994
  • The flow and heat transfer characteristics behind a backward facing step located in a vertical channel has been studied. In this study, the numerical prediction has been performed by solving the Navier-Stokes equation and energy equation simultaneously with the SIMPLE algorithm embedied in TEACH code. Local heat flux was measured by using Schlieren Interferometer. The flow visualization was performed using the cylindrical lens and the laser beam that is scattered by the supplied glycerine particles. The velocity and temperature distributions, recirculation region, reattachment length, and local heat flux are obtained under the various parameters to investigate the buoyancy effect on the flow and heat transfer characteristics behind the step.

  • PDF

CFD에 의한 와류방지장치(AVD)가 설치된 흡수정내 펌프의 성능평가에 관한 연구 (Study on Performance Analysis of Pump within Sump Model with AVD installation by CFD)

  • 최종웅;박노석;김성수;박상수;이영호
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.463-469
    • /
    • 2012
  • The efficiency of the flow mixed pump installed within the bell-mouth in the sump is reduced by the flow characteristics of around intakes. Strong submerged vorticies can be successfully suppressed by installing an AVD(anti-submerged vortex device) on the bottom of pump intake channel just below the bell-mouth. Sump model with AVD device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the efficiency of the pump with the AVD installation in the pump station accurately.

Development of Two-Dimensional Hydrogen Mixing Model in Containment Subcompartment Under the Severe Accident Conditions

  • Lee, Byung-Chul;Cho, Jae-Seon;Park, Goon-Cherl;Chung, Chang-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.663-668
    • /
    • 1996
  • A two-dimensional continuum model for the prediction of the hydrogen mixing phenomena in the containment compartment under the severe accident conditions is developed. The model could predict well the distribution of time-dependent hydrogen concentration for selected HEDL Experiment. For a simulation of these experiments, the hydrogen is mixed uniform over the test compartment. To predict the extent of non-uniform distribution, the dominant factors such as the geometrical shape of obstacle and velocity of source injection in mixing phenomena are investigated. If the obstacle disturbing the flow of gas mixture exists in the compartment, the uniform distribution of hydrogen may be not guaranteed. The convective circulation of gas flow is separately formed up and down of the obstacle position, which makes a difference of hydrogen concentration between the upper and lower region of the compartment. The recirculation flow must have a considerable mass flow rate relative to velocity of the source injection to sustain the well-mixed conditions of hydrogen.

  • PDF

레인가든이 지하유출 및 첨두유량 감소에 미치는 효과 (Effects of Rain Garden on Reduction of Subsurface Runoff and Peak Flow)

  • 김창수;성기준
    • 한국환경복원기술학회지
    • /
    • 제14권5호
    • /
    • pp.69-79
    • /
    • 2011
  • This study assessed the subsurface runoff and peak flow reduction in rain gardens. The results showed that the highest water retention was found in rain garden mesocosms in which Rhododendron lateritium and Zoysia japonica were planted, followed by mesocosms in which either R. lateritium or Z. japonica was planted, and the lowest water retention rate was found in non-vegetated control treatment mesocosms(${\alpha}$ < 0.05). Although higher rainfall intensity caused a decrease of peak flow reduction in both vegetated and non-vegetated treatments, peak flow reduction was the greatest in mesocosms with mixed plants. A rain garden can be an effective tool for environment-friendly stormwater management and improving ecological functions in urban areas. Depending on the purpose such as delaying runoff or increasing infiltration, various plant types should be considered for rain garden designing.

EK Pumps 내의 유동 해석에 관한 연구 (Analysis of fluid flow in EK pumps)

  • 민정임;김성진;김덕종
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1857-1862
    • /
    • 2004
  • EK pumps packed with particles inside capillaries are involved in the mixed electroosmotic flow and pressure driven flow. For analysis in the porous EK pumps, the volume-averaging technique is applied to derive the volume-averaged equations for momentum and electrical potential. By using the volume-averaged equations, analytical solutions for electric potential and velocity distribution due to the mixed electroosmotic and pressure driven flows are obtained. The present analysis is validated by comparison with numerical and experimental results for the case of microchannel EK pumps.

  • PDF

Methylprednisolone을 첨가한 GIK용액의 심근보호효과에 관한 실험적 연구 (An experimental study on the myocardial protection effect of the methylprednisolone mixed GIK solution)

  • 유시원
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.574-586
    • /
    • 1984
  • Although corticosteroid have been shown to stabilize lysosomal membranes and prevent release of hydrolytic enzymes, the mechanism of membrane stabilization remains obscure. This study described functional assessment of efficiency of methylprednisolone in GIK solution by using a isolated Rat Heart Model. Isolated rat heart were subjected to a 2-minute period of coronary infusion with a cold GIK or methylprednisolone mixed cold GIK solution immediately before and also at the midpoint of a 60-minute period of hypothermic [$10{\pm}1^{\circ}C$] ischemic arrest. The result of this were as follow: 1.Spontaneous heart beat after ischemic arrest occurred 11 second later after Langendorffs reperfusion in the methylprednisolone mixed GIK group and 14 second later in the control group. 2.The percentage of recoveries of heart rate at 30 minute after postischemic working heart perfusion was 88.6\ulcorner.6% in the methylprednisolone mixed GIK group. This percentage of recovery was not significantly greater than the control group. 3.The percentage of heart function at 30 minute after postischemic working heart perfusion were; peak aortic pressure $90.8{\pm}4.5%$ coronary flow $87.5{\pm}1.45$ and aortic flow $74.9{\pm}11.8%$ in the methylprednisolone mixed GIK group. This percentage of recovery was significantly greater than the control group. [p<0.05]

  • PDF

메탄-공기 예혼합 선회화염에서 수소첨가와 선회강도 영향에 관한 연구 (A Study on the Effects of Hydrogen Addition and Swirl Intensity in CH4-Air Premixed Swriling Flames)

  • 김한석;조주형;김민국;황정재;이원준
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.593-600
    • /
    • 2019
  • The combustion characteristics of methane/hydrogen pre-mixed flame have been investigated with swirl stabilized flame in a laboratory-scale pre-mixed combustor with constant heat load of 5.81 kW. Hydrogen/methane fuel and air were mixed in a pre-mixer and introduced to the combustor through a burner nozzle with different degrees of swirl angle. The effects of hydrogen addition and swirl intensity on the combustion characteristics of pre-mixed methane flames were examined using particle image velocimetry (PIV), micro-thermocouples, various optical interference filters and gas analyzers to provide information about flow velocity, temperature distributions, and species concentrations of the reaction field. The results show that higher swirl intensity creates more recirculation flow, which reduces the temperature of the reaction zone and, consequently, reduces the thermal NO production. The distributions of flame radicals (OH, CH, C2) are dependent more on the swirl intensity than the percentage of hydrogen added to methane fuel. The NO concentration at the upper part of the reaction zone is increased with an increase in hydrogen content in the fuel mixture because higher combustibility of hydrogen assists to promote faster chemical reaction, enabling more expansion of the gases at the upper part of the reaction zone, which reduces the recirculation flow. The CO concentration in the reaction zone is reduced with an increase in hydrogen content because the amount of C content is relatively decreased.

독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구 (A Study on Blood Flow Measurement Method using Independent Component Analysis)

  • 조석빈;임동석;백광렬
    • 전자공학회논문지SC
    • /
    • 제44권2호
    • /
    • pp.10-17
    • /
    • 2007
  • 의료용 초음파 시스템으로 혈류 속도를 측정할 때, 순수한 혈류 신호의 검출이 필요하다. 초음파 트랜스듀서를 통해 들어오는 반사 신호는 체세포 조직(tissue), 혈관 벽(blood wall), 적혈구(red blood cell), 잡음(noise) 등이 혼합된 신호이다. 혼합된 신호에서 체세포 조직과 혈관 벽 신호를 클러터(clutter)라고 한다. 본 논문에서는 ICA(independent component analysis)를 적용하여 클러터 신호와 잡음을 효과적으로 제거하는 방법을 제시하였다. Field II 초음파 시뮬레이션 프로그램을 이용하여 초음파 반사 신호를 생성하고, ICA를 사용하여 각 독립 신호들을 분리, 클러터 신호를 제거하여 혈류 신호를 추출했다. 추출전 혈류신호를 2D 자기상관(autocorrelation) 방법으로 혈류 속도를 측정했다. 그리고 PCA(principal component analysis)방법을 적용한 고유 필터(autocorrelation) 방법으로 클러터를 제거한 결과와 비교하였다. 그 결과 잡음 환경에서의 혈류 속도 측정에 ICA 방법이 우수한 적용 결과를 보였다.

열장 흐름 분획법에 의한 폴리스티렌의 머무름에 미치는 혼합용매의 영향에 관한 연구 (A Study Effect of Mixed Solvents on the Retention of Polystyrenes Using Thermal Field-Flow Fractionation)

  • 이대운;전선주;박원철
    • 분석과학
    • /
    • 제6권5호
    • /
    • pp.453-462
    • /
    • 1993
  • 본 연구는 열장 흐름 분획법을 이용하여 혼합 용매에서의 폴리스티렌의 머무름을 측정하고 용매의 조성이 시료의 머무름거동에 미치는 영향을 조사하였다. 시료는 분자량이 35,000, 110,000, 200,000, 470,000인 폴리스티렌을, 이동상은 테드라히드로퓨란(THF), 클로로포름(CHL), 시클로헥산(CH), 그리고 벤젠(BZ)의 단일용매 및 혼합용매를 사용하였다. 시료의 분자량과 혼합용매의 조성의 변화에 따라서 시료의 머무름비와 열확산계수를 측정하였으며, 그 값들을 시료와 용매의 물리화학적인 성질과 연관시켜 설명하였다. 즉, 시료의 머무름비는 이동상의 밀도의 영향을 크게 받으며 이동상의 밀도가 클수록 머무름비가 증가함을 알 수 있었다. 또한 이동상에 포함된 poor 용매의 함량이 증가할수록 열확산계수는 감소하였다.

  • PDF