• Title/Summary/Keyword: Mix Design

Search Result 929, Processing Time 0.03 seconds

A Study on the Development of High Strength Concrete for Long Span PSC Beam Bridge(II) (장경간 PSC Beam 교량을 위한 고강도콘크리트의 개발에 관한 연구(II))

  • 백상현;이형준;김기수;엄태선;정원기;황은영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.291-296
    • /
    • 1998
  • In the present study, the high strength concrete which is adequate for the long span PC beam above 40 meters has been developed. The optimum cement for high strength concerete was selected through laboratory tests and in-situ mock-up applications. The optical concrete mix design was performed, and the properties of fresh concrete and hardened concrete have been investigated. These results of laboratory study are analized and compared to domestic and foregn design codes and specifications. Finally, the developed high strength concrete was applied to half-scale PSC beams and showed good applicability in field conditions. It is conclude that hte developed high strength concrete can be applied to civil and architectural structures in the field applications.

  • PDF

Development and Application of Low Permeable Concrete for Underground Structures (지하구조물을 위한 수밀콘크리트의 개발 및 실용화)

  • Paik, S.H.;Park, S.S.;Park, J.Y.;Paik, W.J.;Um, T.S.;Choi, L.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.259-262
    • /
    • 1999
  • In underground reinforced concrete structures, such as drainage structure, water and chloride ion penetrated into concrete through the cracks of concrete and its permeable property, cause the corrosion of reinforcing steel bar, which accelerates the expansive cracks and deterioration of concrete. It is necessary to control those deterioration of underground structure by improving its permeability and durability through the reasonable solutions in design, construction and materials. In the present study, fly ash concrete, which has good material properties in long-term period, was compared and studied with plain concrete using ordinary portland cement in terms of fundamental mechanical properties, permeability, drying shrinkage and durability. Also, the mix design and field test of low permeable concrete using fly ash were performed. From this study, fly ash concrete can control the penetration of water and chloride ion effectively by forming dense micro-structure of concrete. Therefore, fly ash concrete may increase the long-term function, performance and serviceability of underground structures.

  • PDF

Development of High Strength Concrete for the Sleepers of High Speed Rail (고속철도 침목용 고강도콘크리트의 개발)

  • 백상현;엄태선;곽천탁;정재현;박종방;김인재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.755-760
    • /
    • 1998
  • In the present, we have developed high strength concrete for the sleepers of high speed rail and verified its applicability by in-situ applications. Concrete for sleepers is manufactured by steam curing at low temperature(below 55$^{\circ}C$), and should be finished its manufacturing process such as placing, curing, demolding and prestressing in 24 hours. The sleepers need its compressive strength above 350kg/$\textrm{cm}^2$ in 15 hours, air-entrainment for durability and nominal design strength of 600kg/$\textrm{cm}^2$, considering its quality variation at factory. We performed the optimum mix design of concrete and verified the rightness of the use of TYPE III cement. Finally, we have confirmed the manufactured sleepers satisfy the required material properties through in-situ application.

  • PDF

A Study on the Mix Design and the Control of Thermal Crack of Mass Concrete (매스콘크리트의 배합설계 및 온도균열제어에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.533-538
    • /
    • 2001
  • This study was peformed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a results, the optimal mixing conditions were : W/B 41%, unit binder 375kg/$cm^{2}$, FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$cm^{2}$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps.

  • PDF

A Study on Improved Genetic Algorithm to solve Nonlinear Optimization Problems (비선형 최적화문제의 해결을 위한 개선된 유전알고리즘의 연구)

  • 우병훈;하정진
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.13 no.1
    • /
    • pp.97-97
    • /
    • 1988
  • Genetic Algorithms have been successfully applied to various problems (for example, engineering design problems with a mix of continuous, integer and discrete design variables) that could not have been readily solved with traditional computational techniques. But, several problems for which conventional Genetic Algorithms are ill defined are premature convergence of solution and application of exterior penalty function. Therefore, we developed an Improved Genetic Algorithms (IGAs) to solve above two problems. As a case study, IGAs is applied to several nonlinear optimization problems and it is proved that this algorithm is very useful and efficient in comparison with traditional methods and conventional Genetic Algorithm.

The Study on the Doubleness of Rene Magritte appeared in the Architecture of O.M.Ungers (O.M.Ungers의 건축에서 나타나는 르네 마그리트의 이중성에 관한 연구)

  • 이병욱;김용승;박용환
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.1
    • /
    • pp.38-45
    • /
    • 2004
  • One of the prominent phenomena since 1960's is the diversity of concepts. It is to deny the standard of meta structure in judging value as a framework of truth understanding. M. Foucault says that we are living in a synchronous, parallel, and scattered epoch. In the architectural approach and interpretation of Ungers, such a phenomenon appears as multi-dimensional relations. The works of Ungers show the concrete manifestation of such thoughts since 1960's. He has exerted significant influence on German architecture through his book ‘Architecture as Theme’ and architectural works. His architecture has focuses on analogy and abstraction on the foundation of his well defined theory. As the features, it shows dialectic relations, mix of confrontation, interests in geometry and morphology. In this respects, the paper tries to find out the relationship between his architectural thoughts and the paintings of Rene Magritte in terms of the attributes of doubleness in the sense of a paradox. Ungers himself refers that he was directly influenced by Magritte.

Remediation of A DNAPL Contaminated Site Using Containment WALL (차단벽을 이용한 DNAPL 오염지역의 복구)

  • Lee, Kwang-Yeol;Joo, Wan-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.81-85
    • /
    • 1998
  • In the present study, the design method of containment walls is proposed by utilizing an existing site. The selected remedy for the Source Area of Operable Unit 2 at Hill Air Force Base stipulated containment of the pure-phase trichloroethylene contamination. The in-place-mixed wall construction was selected because of the irregular topography, small area of the site, and the requirement to reach depths of greater than 90 feet below ground surface. Bench-scale compatibility studies were performed for the containment wall mix design on three commercial bentonite clays. The samples were subject to screening tests and long-term tests for evaluation of changed soil properties when exposed to the contaminated groundwater.

  • PDF

Time-Dependent Deformation and Durability of High-Strength Concrete over 60MPa for PSC Bridges (PSC 교량용 설계강도 60MPa 이상 고강도 콘크리트의 실용화를 위한 시간의존적 변형 및 내구성에 관한 연구)

  • Yang, Jun-Mo;Lee, Joo-Ha;Cheong, Hai-Moon;Ahn, Tae-Song;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.5-8
    • /
    • 2006
  • In this study, various fundamental experiments including durability and time-dependent deformation are performed to compile a database for a utilization of high-strength concrete for PSC bridges. In the mix design, concrete strength at early age when prestressing forces are introduced to the PSC member and slumpflow suitable for pumping of concrete are considered to make a concrete fit for PSC bridges. The main parameters investigated are the kinds and replacement ratios of mineral admixtures and low-heat cement. Experimental tests on durability include penetration of chloride ions, freezing-thawing, combined deterioration, and simple adiabatic temperature rise test. In addition, time-dependent deformation such as creep, drying and autogenous shrinkage, which is particularly important factor in the design and construction of PSC bridges, is tested and analyzed.

  • PDF

A novel design of DC-DC converter for photovoltaic PCS

  • Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2009
  • Renewable energy resources will be an increasingly important part of power generation in the new millennium. Besides assisting in the reduction of the emission of greenhouse gases, they add the much needed flexibility to the energy resource mix by decreasing the dependence on fossil fuels. Due to their modular characteristics, ease of installation and because they can be located closer to the user, PV system have great potential as distributed power source to the utilities. In this paper, a dc-de power converter scheme with the push-pull based technology is proposed to apply for solar power system which has many features such as high efficiency, stable output, and low acoustic noises, DC-DC converter is used in proposed topology has stable efficiency curve at all load range and very high efficiency characteristics. This paper presents the design of a single-phase photovoltaic inverter model and the simulation of its performance.

A Design of Realtime Monitoring System of Automatic gas Control DC-MOTOR for Single Crystal($A1_2O_3$) growth (단결정($A1_2O_3$) 성장을 위한 자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 구현)

  • Lee, Hyung-Chung;Park, Chong-Kug;Cho, Hyeon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2489-2491
    • /
    • 2004
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal($A1_2O_3$) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($A1_2O_3$) growth and we will design about realtime monitoring systems of the automatic gas control DC- Motor for single crystal($A1_2O_3$) growth.

  • PDF