• 제목/요약/키워드: Minimum ventilation rate

검색결과 38건 처리시간 0.025초

전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계 (Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology)

  • 권경석;이인복;황현섭;;홍세운;서일환;최지선;송상현;문운경
    • 한국농공학회논문집
    • /
    • 제52권3호
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

플라스틱 단동온실의 천창 종류에 따른 자연환기 효과 (Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse)

  • 라쉬드아드난;이종원;김현태;이현우
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.225-233
    • /
    • 2019
  • 여름철에 자연환기는 온실의 온도를 낮추는데 중요한 역할을 한다. 온실의 형태, 환기창 종류, 환기창의 위치 등은 자연환기 성능에 큰 영향을 미친다. 본 연구에서는 전산유체역학(CFD)을 이용하여 다양한 천창구조에 대하여 측창에 따른 부력환기 효과를 비교분석 하였다. Boussinnesq 가정을 사용하여 전체 계산영역에 대한 부력효과를 시뮬레이션 하였다. 또한 RNG $K-{\varepsilon}$ 난류모델을 사용하였다. 일사량 효과를 시뮬레이션 하기 위해 Solar ray tracing과 함께 Discrete originates (DO) radiation 모델을 사용하였다. 실험온실 내부의 온도를 측정하여 CFD모델을 검증하였으며, 실험값과 계산값이 잘 일치하는 것으로 나타났다. 7가지의 천창구조에 대하여 온실의 내외부 온도차이와 환기횟수를 비교하였다. 내외부온도의 차이는 $3.2{\sim}9.6^{\circ}C$ 범위로 나타났고, 환기횟수는 $0.33{\sim}0.49min^{-1}$ 범위로 나타났다. 고깔형 천창구조 온실의 경우 내외부 온도차이가 $3.2^{\circ}C$로 가장 낮았고 환기횟수도 $0.49min^{-1}$로 가장 높게 나타나 환기효과가 가장 우수한 것으로 나타났다.

공동주택의 기밀성능 평가 및 에너지 절감효과 분석 (An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing)

  • 이승복
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.119-125
    • /
    • 1995
  • 지금까지 우리는 건물분야에서의 합리적인 에너지 사용을 위하여 건물외피의 단열성능을 향상시킴으로써 열손실을 줄이려는 데에 주력하여 왔으며, 침기로 인한 열손실을 줄이려는 노력은 상대적으로 미흡하였다. 그러나, 침기로 인한 난방에너지의 소비가 상당량에 이르는 것으로 조사됨으로써 재실형태에 따라 최소환기기준을 만족시키면서 침기에 의한 불필요한 에너지의 손실을 줄이려는 노력이 매우 유효한 것으로 평가되고 있다. 실제로 침기에 의한 불필요한 에너지의 낭비가 얼마나 되는가를 평가하기 위해서는, 건물에서의 침기율을 정확하게 측정할 수 있는 방법이 전제되어야 한다. 본 연구에서는 감압/가압법의 일종인 Blower Door System을 사용하여 공동주택에서의 기밀성능을 측정, 평가함은 물론 측정결과를 토대로 합리적인 수준까지 기밀화할 경우 난방에너지의 절약가능성에 대하여 추정하였다.

  • PDF

무창육성돈사의 환기시스템에 따른 환기효율 평가 (Evaluation of Ventilation Systems in an Enclosed Growing Pig House)

  • 송준익;최홍림
    • Journal of Animal Science and Technology
    • /
    • 제44권1호
    • /
    • pp.135-144
    • /
    • 2002
  • 본 실험은 우리 나라의 양돈농가에서 노동력 절감이라는 이점 때문에 자돈사 및 분만사의 무창돈사는 일반농가에까지 보급되고 있으나, 육성.비육돈사에 있어서 무창돈사는 거의 전무한 실정으로 질병의 근원적인 차단 및 관리를 위하여 지금까지 회피되어 왔던 무창 육성.비육돈사의 활성화를 위하여 환기시스템을 자체적으로 고안하여 최적의 환기시스템을 여름철 및 겨울철로 구분하여 건축하였으며, 자체적으로 고안한 환기시스템의 성능을 평가하고자 겨울철 및 여름철로 구분하여 시험한 결과를 요약하면 다음과 같다. 1. 무창 육성.비육돈사에 있어서 돼지 생활공간(하부) 지점에서의 공기유속은 겨울철 최소환기 수준(1,440 $m^3/h$)으로 하였을 때 0-0.19 m/s 였으며, 여름철 최대환기 수준(24,000 $m^3/h$)에서는 0.07-0.42 m/s로 분포되어 여름철 및 겨울철의 무창돈사내 공기유속으로 보아 환기시스템이 우수하였다. 이상의 실험결과를 종합해 보면 무창 육성.비육사의 환기시스템은 여럼츨 때는 측벽을 통한 환기와 겨울철은 천장을 통한 환기시스템이 적합하다고 판단되었으며, 한쪽 측벽에 의한 배기시스템이라도 입기구는 양쪽 측벽을 통한 입기가 우수하다는 것을 알 수 있었다.

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

지하철 터널내 열차풍 예측 프로그램 개발에 관한 연구 (A Study on the Development of the Train Wind Rate Prediction Program in Tunnel of the Subway)

  • 김종열;최광환
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.38-44
    • /
    • 1999
  • Subway is one of the most important transportation and its facilities are increased by the drift of population to cities in these days. But heat generation results from lighting, human and traffic increase in subway, half-closed space, gives uncomfortable sense to the subway passengers. Therefore, natural ventilation by piston effect is done to relieve uncomfortable sense. But train wind by piston effect gives uncomfortable sense to the subway passengers, too. So the numerical calculation of inflow and outflow amounts is important to predict thermal environment and reduce train wind. In case of actual survey of train wind in target station, the amount of train wind are about $3100m^3/train$ at the minimum, about $6000m^3/train$ at the maximum, about $4200m^3/train$ on average. When comparison between simulation for train wind prediction and actual survey for accuracy was done train wind prediction program showed similar results.

  • PDF

태안 시설원예단지의 온실 냉난방 부하 분석 (Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean)

  • 서원명;배용한;허해준;곽철순;이석건;이종원;윤용철
    • 한국농공학회논문집
    • /
    • 제51권6호
    • /
    • pp.45-52
    • /
    • 2009
  • This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구 (Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel)

  • 유지오;김진수;이동호
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.68-74
    • /
    • 2016
  • 도로터널에 적용하는 반횡류환기방식은 터널의 전연장에 걸쳐서 단위길이당 풍량이 균일하게 될 수 있도록 포트의 개도 조정이 필수적이다. 그러나 현재 국내에서 운영중인 터널의 경우에는 설계시 이에 대한 고려가 적절히 이루어지지 못하고 있는 실정이다. 이에 본 연구에서는 개도계산을 위한 프로그램을 개발하고 반횡류환기방식의 터널에서 포트의 운영방안을 제시하였다. 연구결과, 포트의 개도는 급기방식의 덕트에서는 환기소측에서 덕트의 말단(bulk head)쪽으로 갈수록 증가하였다가 감소하는 경향을 가지며, 최소 개도는 56% 정도로 나타나고 있다. 또한 배기방식에서는 환기소측이 15% 정도로 가장 작고 bulk head 쪽으로 갈수록 증가하는 경향을 보이고 있다. 화재시 300 m 구간의 배연풍량을 검토한 결과, 포트사이즈를 조정하지 않는 경우와 급기방식으로 포트사이즈을 조정한 경우에는 터널중앙부의 배연량이 각각 8.1%와 12.5%로 터널중앙부의 배연풍량이 저조한 것으로 나타났다. 따라서 반횡류환기방식의 터널에서는 평상시 환기효율이 저하하더라도 배연시 균일한 풍량을 얻을 수 있도록 포트의 개도를 설정하여 운영하는 것이 반드시 필요한 것으로 판단된다.

Ammonia and Carbon Dioxide Concentrations in a Layer House

  • Kilic, Ilker;Yaslioglu, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권8호
    • /
    • pp.1211-1218
    • /
    • 2014
  • Higher concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in animal barns can negatively affect production and health of animals and workers. This paper focuses on measurements of summer concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in a naturally ventilated laying henhouse located at an egg production facility in Bursa region, western Turkey. Also, indoor and ambient environmental conditions such as temperature and relative humidity were measured simultaneously with pollutant gas concentrations. The average $NH_3$ concentrations during summer of 2013 was 8.05 ppm for exhaust and 5.42 ppm for inlet while average $CO_2$ concentration was 732 ppm for exhaust and 625 ppm for inlet throughout summer. The overall minimum, average and maximum values and humidity were obtained as $16.8^{\circ}C$, $24.72^{\circ}C$, and $34.71^{\circ}C$ for indoor temperature and 33.64%, 63.71%, and 86.18% for relative humidity. The lowest exhaust concentrations for $NH_3$ and $CO_2$ were 6.98 ppm and 609 ppm, respectively. They were measured in early morning at the maximum diurnal ventilation rate in July 2013 and August 2013. The highest concentrations were 10.58 ppm for $NH_3$ and 904 ppm for $CO_2$ recorded in the afternoon when the ventilation rate was the lowest in June 2013.