• 제목/요약/키워드: Minimum sustain voltage

검색결과 15건 처리시간 0.024초

AC Plasma Display Panel with Irregular Micro-scale Holes in the Front Dielectric Layer

  • Cho, Kwan-Hyun;Ahn, Sung-Il;Kim, Woo-Hyun;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.711-712
    • /
    • 2009
  • The fabrication of micro-scale irregular holes by using PMMA (Poly Methyl Methacrylate) beads in the front dielectric layer was proposed to improve luminous efficacy of an ac plasma display panel. Through the firing process of front dielectric layer, bowl shaped holes with a depth of $2.5{\mu}m$, a top diameter of $8-12{\mu}m$, and a bottom diameter of $4-7{\mu}m$ were fabricated. The proposed ac plasma display panel with the irregular micro-scale holes improved the luminous efficacy by 18 % due to the decrease in the minimum sustain voltage.

  • PDF

표면 방전형 AC PDP의 셀 구조와 방전특성의 상관관계에 관한 연구 (A Study on the Relationship between Cell Structure and Discharge Characteristics of Surface Discharge AC PDP)

  • 신중홍;이우근;김준호;김규섭;유충희;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.133-140
    • /
    • 1999
  • The relationships between discharge characteristics and sustain electrode shape are studied in AC PDP by calculating the electric field and measuring discharge voltage, luminance and current. The maximum electric field is obtained for the triangle shape electrode. It is 1.8 times larger than uniform electric field type. It has been shown thatthe firing voltage is largely affected by the degree of electric field concentration. But, as the difference of the maximum and minimum value of electric field in a cell increases, the luminance and luminance efficiency decrease. And, the charge variation during discharge is proportional to the area of electrode.

  • PDF

방전에너지 제어에 의한 최소점화에너지의 고찰 (A Study on Minimum Ignition Energy by Controlled Discharge Energy)

  • 최상원;대택돈
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.36-39
    • /
    • 2007
  • It is important to know Minimum Ignition Energy(MIE) of flammable materials for ignition hazard of chemical processes etc.. Currently a capacitor discharge is used mainly to measure the MIE. Then, it is impossible to control actively discharge energies and discharge time because the MIE measurement uses a high voltage capacitor and fixed capacitor. However, the control of discharge energy and discharge time will be convenient if self-sustain discharge is used. In this paper, we measured the MIE by self-sustain discharge of a pulse shape to propose the new measuring method of the MIE. AS a result, ignition energies are increased gradually as discharge duration time gets longer, and discharge current grows larger. Also, an arc discharge and a glow discharge occurred during the experimental period, and the ignition by glow discharges happened when discharge duration time was $90{\mu}s$, discharge current was 8A and 1A Especially, the MIE occurred the 0.05mm and 0.08mm of the gap distance between discharge electrode in the same discharge duration time.

ac-PDP의 전압전달특성에 미치는 방전가스의 영향 (The effects of discharge gases in the voltage transfer curve of ac-PDP)

  • 손진부;이성현;김동현;김영대;조정수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2233-2235
    • /
    • 1999
  • The ac plasma display panel(PDP) is a flat light-emitting gas discharge device. Discharge gases directly take effects to the discharge phenomena of ac PDP. Therefore it is necessary to understand the characteristics of the discharge gases. In this paper, we have studied the effects of discharge gases by voltage transfer curves which show the discharge characteristics of ac PDP and the change of the effective wall capacitance during a discharge which depends on lateral spreading of charge distribution and the strength of discharge. As gas pressure increases, memory margins increases. and the firing voltage of a mixed gas is lower than that of a single gas such as He gas. The minimum sustain voltage and the maximum sustain voltage or firing voltage increases with decrease in the frequency. The effective wall capacitance increases as the discharge strength that is, the gap voltage between discharge electrodes increases.

  • PDF

AC PDP의 장방전 구조의 구동을 위한 새로운 리셋파형 (New Reset Waveform for a Large-Sustain-Gap Structure in AC PDPs)

  • 김선;김동훈;송태용;김지용;이석현;서정현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1544-1545
    • /
    • 2006
  • In this paper, we present a new reset waveform for a large-sustain-gap structure in at PDPs. In the driving of the large-sustain-gap structure with a conventional ramp reset waveform, we cannot avoid the condition of an address being a cathode, which causes lots of trouble in stabilizing a reset discharge. To solve these problems, we use the square pulse instead of the conventional rising ramp pulse. Before making a strong discharge between the address (cathode) and scan (anode) electrodes, we make a priming discharge between the address (anode) and the scan (cathode) electrodes to stabilize the strong discharge in which the address electrodes are the cathode. With this scheme, we obtained 60V minimum address voltage and 145V maximum address voltage in $250{\mu}m$ and $350{\mu}m$ gap structures.

  • PDF

AC-PDP특성평가를 위한 전압전달곡선 계측에 관한 연구 (Measurement of Voltage Transfer Curve in AC PDP)

  • 손진부;이성현;김동현;김영대;조정수;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.395-398
    • /
    • 1999
  • In ac PDP(plasma Display Panel), the discharge characteristics is very important to display clear images. In this paper, we have studied the measurement of voltage transfer curves which show the discharge characteristics in AC PDP. The change of the effective wall capacitance during a discharge is also studied. These depend on lateral spreading of charge distribution and the strength of the discharge. As a parameter of the frequency, we observed the effects of the frequency in voltage transfer curves and in effective wall capacitance changes. As frequency increases, minimum sustain voltage and firing voltage decrease. In upper region of gap voltage the chance of the effective wall capacitance is independent of frequency.

  • PDF

AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성 (The Characteristics of the Discharge According to ITO Gap by the CLHS Driving Method in AC PDP)

  • 신재화;최명규;김근수
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.83-89
    • /
    • 2013
  • In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of $65{\mu}m$, $80{\mu}m$, and $100{\mu}m$ in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of $100{\mu}m$, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of $100{\mu}m$, the self-erasing discharge was improved in the sustain period. Also, the $V_S$ and $V_A$ minimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of $100{\mu}m$, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of $100{\mu}m$ increased about 26.3% at the discharge load of 4% compared with that at ITO gap of $65{\mu}m$.

Ion Plating법에 의해 제작된 MgO 박막의 특성 및 AC PDP에의 응용 (The characteristics of MgO films prepared by Ion Plating and its applications to AC PDP)

  • 정동철;정희섭;신범재;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.255-257
    • /
    • 1993
  • MgO(Magnesium Oxide) film was deposited by the Ion Plating method and the characteristics of the MgO films were analyzed by XRD and SEM. The MgO films prepared by Ion Plating were used in AC Plasma Display Panel and breakdown voltage, minimum sustain voltage and memory margin of fabricated panel were investigated.

  • PDF

교류형 플라즈마 디스플레이 패널에서 계조표현을 위한 새로운 구동방식 (A New Driving Method for Gray-scale Expression in an AC Plasma Display Panel)

  • 김재성;황현태;서정현;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.407-414
    • /
    • 2004
  • In this paper, a new gray scale expression method that divides the scan lines into multiple blocks is suggested. The proposed method can drive 16 sub-fields per 1 TV field in the panel with XGA ($1366{\times}768$) resolution. The on and off states of even subfields depend on the condition of odd subfields. The write address mode is used in the odd subfields, while the erase address mode is used in the even subfields. Because the ramp reset pulse is applied every 2 sub-fields, both the contrast ratio and the dynamic voltage margin are sufficiently obtained in comparison with previous AWD (Address While Display) methods. In realizing 16 subfields, shortening the scan time in the erase address period was important. The X bias voltage in the erase address period affected the minimum address voltage but did not the delay time of the address discharge. The delay time of the address discharge was affected by the address voltage and the time interval between the last sustain discharge and the scanning time. We also evaluated the dynamic false contour. New method shows an improved image quality in horizontal moving, but discontinuous lines were observed at the boundaries of each block in vertical moving

Photon-induced surface conductivity measurement of MgO in an AC PDP

  • Ha, Chang-Hoon;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.130-133
    • /
    • 2006
  • In order to study the relationship between the discharge characteristics of an ac PDP and the surface conductivity of MgO thin film, the surface current across a ring shaped MgO film was measured by exposure to monochromatic vacuum ultraviolet from the synchrotron radiation source whose wavelength ranges from 60nm to 240nm $(5.5eV{\sim}25eV)$. The experimental results show that the surface current begins to increase rapidly at the photon energy of about 9 eV which might correspond to the valence band edge of MgO. The difference in the surface current level correlate well with the differences in the preparation method of MgO films and their respective discharge characteristics such as the firing, minimum sustain voltages, address voltage margin and address discharge delay time.

  • PDF