• Title/Summary/Keyword: Minimal period

Search Result 430, Processing Time 0.031 seconds

Combined Percutaneous and Minimal on Internal Fixation of Calcaneal Fractures Using Extensile Lateral Approach (광범위 외측 도달법을 이용한 종골 골절의 경피적 및 최소 내고정술)

  • Yu, Sun-O;Kim, Joo-Sung;Kim, Jong-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.201-207
    • /
    • 2002
  • Purpose: To present the clinical analysis of the results obtained in 38 cases of displaced intraarticular calcaneal fractures undergone combined percutaneous axial pin fixation of calcaneal body and minimal internal fixation using extensile lateral approach. Materials and Methods: From March 2000 to February 2002, thirty-eight displaced intraarticular fractures of the calcaneus in 35 patients were fixed with 3.5mm cannulated screws and percutaneous 2.5mm K-wires. The extensile lateral approach was used in all cases. The average follow-up period was 16 months. Clinical evaluation was assessed according to the Ankle-Hind Foot Scale of American Orthopedic Foot and Ankle Society. Results: The clinical results were graded as excellent in 8 cases(21%), good in 22 cases(58%), fair in 6 cases(16%), and poor in 2 cases(5%). Two cases of poor result were type IV of Sanders classification. The postoperative reduction status of the articular surface was analyzed by computed tomography in all cases and was found to be less 2mm of step off in 30 cases and between 2 and 4mm in 8 cases. Unsatisfactory results were correlated with severity of articular comminution and failure to obtain accurate reduction of the articular surface. Using early functional postoperative care, all fractures healed without secondary displacement except 1 case on an average of ten weeks. Two cases had superficial necrosis of the wound margins, however, secondary wound healing was uneventful and skin grafting was not needed. Conclusion: Combined minimal internal fixation and percutaneous pin fixation using extensile lateral approach is useful operative method of intraarticular calcaneal fractures because providing enough stability to permit functional aftercare and allowing excellent anatomical reduction. In addition, this method diminishes the risk of lateral soft tissue problems.

  • PDF

A Bayesian Approach to Optimal Replacement Policy for a Repairable System with Warranty Period

  • Jung, Gi-Mun;Han, Sung-Sil
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.1
    • /
    • pp.21-31
    • /
    • 2002
  • This paper considers a Bayesian approach to determine an optimal replacement policy for a repairable system with warranty period. The mathematical formula of the expected cost rate per unit time is obtained for two cases : RFRW(renewing free-replacement warranty) and RPRW(renewing pro-rata warranty). When the failure time is Weibull distribution with uncertain parameters, a Bayesian approach is established to formally express and update the uncertain parameters for determining an optimal replacement policy. Some numerical examples are presented for illustrative purpose.

Optimal Replacement Policy for a Repairable System with Combination Warranty (혼합보증이 있는 수리 가능한 시스템에 대한 최적의 교체정책)

  • 정기문
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.1
    • /
    • pp.107-117
    • /
    • 2002
  • In this paper we present the optimal replacement policies following the expiration of combination warranty. We consider two types of combination warranty policies: renewing warranty and non-renewing warranty. The criterion used to determine the optimal replacement period is the expected cost rate per unit time from the user'perspective. The optimal maintenance period following the expiration of combination warranty is obtained. Some numerical examples are presented for illustrative purpose.

Warranty Cost Models for a Product Subject to Two Types of Failure (두 가지 고장(故障) 형태(形態)를 가진 제품(製品)에 대한 보증비용(保證費用) 모형(模型))

  • Bae, Do-Seon;Kim, Su-Myeong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.14 no.2
    • /
    • pp.81-90
    • /
    • 1988
  • This paper is concerned with warranty cost models for a product with two types of failure ; type 1 failures corrected by minimal repair and type 2 failures removed only by replacement. Two warranty policies involving an initial free service period followed by a pro-rata period are considered ; the difference is whether the warranty is renewed or not when type 2 failure occures during its free service period. Expected warranty costs under the two policies are obtained, and their behaviors are examined for the case where type 1 and 2 failure distributions are Weibull and exponential, respectively.

  • PDF

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

The Early Results of Linear Distal Metatarsal Osteotomy with Minimal Incision for Correction of Hallux Valgus (무지 외반증의 교정에 있어 최소 절개를 이용한 원위 중족골 선상 절골술의 초기 수술 결과)

  • Eun, Il-Soo;Jung, Chul-Yong;Kim, Byung-Cheol;Choi, Sung-Jong;Ku, Jeong-Mo;Choi, Hyeon-Soo;Huh, Jung-Wook;Yoo, Chong-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.160-165
    • /
    • 2007
  • Purpose: Good results using minimal invasive hallux valgus surgery has been reported recently. We evaluate the usefulness of linear distal metatarsal osteotomy with minimal skin incision in mild and moderate hallux valgus deformity. Materials and Methods: Twenty-eight patients (thirty-one cases) who had mild to moderate hallux valgus deformity and underwent linear distal metatarsal osteotomy using minimal skin incision were evaluated between February 2005 and February 2006. Hallux-metatarsophalangeal-interphalangeal scale of AOFAS (American Orthopaedic Foot and Ankle Society) score was used as clinical evaluation. Preoperative, postoperative, after pin removal, and final follow up plain radiographs were used as radiologic evaluation. Results: Twenty-six cases (83%) among thirty-one cases showed more than average satisfaction, Average AOFAS score were improved from 63.2 points (range 45-74 points) to 86.4 points (range 67-93 points). Preoperative radiologic index of IMA $14.0^{\circ}$ (range $10-18^{\circ}$), HVA $30.2^{\circ}$ (range $19-39^{\circ}$), DMAA $13.8^{\circ}$ (range $5-23^{\circ}$) were improved postoperatively as IMA $8.3^{\circ}$ (range $5-10^{\circ}$), HVA $10.5^{\circ}$ (range $2-20^{\circ}$), DMAA $7.2^{\circ}$ (range $0-14^{\circ}$) correctively. Mean operative time was 15.5 minutes (range 11-18 minutes) and mean operative time was 5.6 days (range 2-8 days). Conclusion: Despite small skin incision and short operative time and admission period, linear distal metatarsal osteotomy with minimal skin incision showed similar results with conventional distal metatarsal osteotomy. Thus, it was thought to be useful operation in mild and moderate hallux valgus deformity.

  • PDF

ON CONTINUED FRACTIONS, FUNDAMENTAL UNITS AND CLASS NUMBERS OF REAL QUADRATIC FUNCTION FIELDS

  • Kang, Pyung-Lyun
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.27 no.2
    • /
    • pp.183-203
    • /
    • 2014
  • We examine fundamental units of quadratic function fields from continued fraction of $\sqrt{D}$. As a consequence, we give another proof of geometric analog of Ankeny-Artin-Chowla-Mordell conjecture and bounds for class number, and study real quadratic function fields of minimal type with quasi-period 4.

Warranty Cost Analysis and Its Application to Replacement Policy for a Repairable Warranted Item (수리가능한 품목의 보증비용분석과 응용)

  • Son, Eun-Il;Suh, Yong-Sung;Park, Young-Taek
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.3
    • /
    • pp.54-65
    • /
    • 1994
  • A hybrid warranty policy for a repairable item is considered. Assuming that minimal repairs ar e performed for failures during warranty period, present worth of warranty cost is derived from a supplier's viewpoint. An optimal preventive periodic replacement policy for the case is also derived from a user's viewpoint Numerical examples are presented in order to explain the results.

  • PDF

A Semi-empirical Mass-loss Rate in Short-period CVs

  • Kim, Woong-Tae;Sirotkin, Fedir V.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.76.2-76.2
    • /
    • 2010
  • We present the final results of our study on the mass-loss rate of donor stars in cataclysmic variables (CVs). Observed donors are oversized in comparison with those of isolated single stars of the same mass, which is thought to be a consequence of the mass loss. Using the empirical mass-radius relation of CVs and the homologous approximation for changes in effective temperature T2, orbital period P, and luminosity of the donor with the stellar radius, we find the semi-empirical mass-loss rate M2dot of CVs as a function of P. The derived M2dot is at ~10-9.5-10-10 $M\odot$/yr and depends weakly on P when P > 90 min, while it declines very rapidly towards the minimum period when P < 90 min. The semi-empirical M2dot is significantly different from, and has a less-pronounced turnaround behavior with P than suggested by previous numerical models. The semi-empirical P-M2dot relation is consistent with the angular momentum loss due to gravitational wave emission, and strongly suggests that CV secondaries with 0.075 $M\odot$ < M2 < 0.2 $M\odot$ are less than 2 Gyrs old. When applied to selected eclipsing CVs, our semi-empirical mass-loss rates are in good agreement with the accretion rates derived from the effective temperatures T1 of white dwarfs. Based on the semi-empirical M2dot, SDSS 1501 and 1433 systems that were previously identified as post-bounce CVs have yet to reach the minimal period.

  • PDF

Replacement Model Based on Cost and Downtime

  • Jung, Ki-Mun;Han, Sung-Sil;Lim, Jae-Hak
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.4
    • /
    • pp.889-901
    • /
    • 2003
  • In this paper, we consider the optimal replacement policies following the expiration of the combination warranty. The combination warranty can be divided into the renewing combination warranty and the non-renewing combination warranty. The criterion used to determine the optimal replacement period is the overall value function based on the expected cost and the expected downtime. Thus, we obtain the expected cost rate per unit time and the expected downtime per unit time for our model. And then the overall value function suggested by Jiagn and Ji(2002) is applied to obtain the optimal replacement period. The numerical examples are presented for illustrative purpose.

  • PDF