• Title/Summary/Keyword: Miniaturized

Search Result 680, Processing Time 0.024 seconds

Static Chaos Microfluid Mixers Using Alternating Whirls and Laminations (미소블록에 의한 교차 회전유동과 미소유로에 의한 박층유동을 이용한 정적 혼돈 미소유체 혼합기에 관한 연구)

  • Chang, Sung-Hwan;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1549-1556
    • /
    • 2004
  • We have deigned, fabricated and compared four different types of static chaos microfluid mixers, including the mixers using straight channel flow, microblock-induced alternating whirl flow, microchannel-induced lamination flow, and combined alternating whirl-lamination flow. Among them, the alternating whirl-lamination (AWL-type) mixer, composed of 3-D rotationally arranged microblocks and dividing microchannels fabricated by conventional planar lithography process, is effective to reduce the mixing length over wide flow rate ranges. We characterize the performance of the fabricated mixers, through the flow visualization technique using phenolphthalein solution. We verify that the AWL-type microfluid mixer shows the shortest fluid mixing length of 2.8mm∼5.8mm for the flow rate range of Re=0.26∼26 with the pressure drop lower than 5kPa. Compared to the previous mixers, requiring the mixing lengths of 7∼17mm, the AWL-type microfluid mixer results in the 60% reduction of the mixing lengths. Due to the reduced mixing lengths within reasonable pressure drop ranges, the present micromixers have potentials for use in the miniaturized Micro-Total-Analysis-Systems($\mu$TAS).

The Study on Measurement of In-Plane Displacement in Mechanical Structure applied to Washing Machine using ESPI (ESPI를 이용한 세탁기 적용 기계 구조물의 면내변위 측정에 관한 연구)

  • Lee, Hac-Ju;Kim, Sang-Tea;Choi, Eun-Oh;Chang, Seog-Weon
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.108-113
    • /
    • 2001
  • Recently, the mechanical structures applied to many industrial products, especially in electronic products, appear to be miniaturized and complicated. This trend makes it difficult to analyze the stress distribution of those mechanical structures and generates new challenges for precise measurement of strain. Therefore, generally most of those cases largely depend on the finite element analysis. But the development of optical metrology which has the capability of non-contact, full-field and precise measurement makes it possible to solve these measuring problems. Among the optical measurement techniques, the electronic speckle pattern interferometry (ESPI) has been developed and considered as one of the most useful tools for measuring displacement and deformation. But the shortage of recognition and difficulties of measurement have limited its industrial applications in spite of its excellent capabilities. Therefore in this study, in order to enhance the industrial application of ESPI, the measurement of in-plane displacement of mechanical structure with ESPI, which is applied to washing machine and cannot be measured by strain gauges, was performed. And the verification of validity of FEA results was also done.

  • PDF

High-output Piezoelectric Micropump Using Active Check Valves (능동형 체크 밸브를 이용한 고출력 압전 마이크로펌프)

  • Park, Jung-Ho;Yoshida, Kazuhiro;Yokota, Shinichi;Ham, Young-Bog;Yun, So-Nam
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1864-1869
    • /
    • 2003
  • A novel piezoelectric micropump using active check valves in place of conventional passive check valves in inlet and outlet has been proposed and investigated. It actively controls open/close motion of check valves using piezoelectric actuator for expansion/contraction of pump chamber. In this paper, bi-directional flow characteristics and load characteristics are experimentally investigated using an adequate timing control for valve closing motion with a prototype micropump fabricated with the effective size of $17{\times}8{\times}11mm^{3}$. From the experimental results, it is ascertained that optimal values of phase shift against voltage to drive pump chamber for realization of a miniaturized but powerful micropump, are $15^{\circ}$ in inlet check valve and $195^{\circ}$ in outlet. Based on the obtained results, a sheet-type active shuttle valve that has a unified valve-body for inlet and outlet check valves is proposed. A micropump with the effective size of $10{\times}10{\times}10mm^{3}$ is fabricated and basic characteristics are experimentally investigated.

  • PDF

Evaluation of Mechanical Properties on Cryogenic Structrual Steel JN1 Weldments and Heat Treated Materials by Using Miniaturized Small Specimen (소형 시험편에 의한 극저온 구조용강 JN1의 용접부 및 열처리재의 기계적성질 평가)

  • Gwon, Il-Hyeon;Hashida, Toshiyuki;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.6 no.9
    • /
    • pp.905-918
    • /
    • 1996
  • 초전도 마그네트 구조용 부재로 최근 개발된 오스테나이트계 스테인레스강 JN1 모재, GTA 용접부 및 열처리재에 대한 기계적 성질을 조사하기 위해 실온(293K)에서 극저온(4K)까지의 온도에서 소형펀치(Small Punch)시험을 실시하였다. GTA 용접부의 용융선 근방의 극저온 기계적 성질은 모재와 용접금속에 비해 크게 저하하였다. 4K에서 실험된 용융선 시험편으로 얻어진 하중-변위곡선상에서 부하의 초기 단계에 보통의 서레이션과 다른 pop-in이 관찰되었고, 이때 시험편 표면의 용융선 근처에서 약 0.1-1mm 정도의 크랙이 발생하였다. 열처리재의 기계적 성질은 열처리 시간과 온도의 증가 또는 시험온도의 저하에 따라 크게 저하되었다. 위의 결과에 기초하여 본 연구에서 실시한 소형 시험편을 사용하는 SP 시험법은 극저온에서 JN1 강의 모재와 열처리재뿐 만 아니라 GTA 용접부의 기계적 성질을 평가할 수 있는 유용한 시험법이었다.

  • PDF

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

Handheld OCT probe for Evaluation of Tympanic Membrane Status (OCT용 손잡이 형 프로브를 이용한 고막 상태 평가)

  • Kwon, Hyeong-Il;Kim, Yee-Hyuk;Cho, Nam-Hyun;Jeong, Hyo-Sang;Kim, Jee-Hyun;Lee, Sang-Heun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.285-288
    • /
    • 2011
  • In this study, we developed an optical coherence tomography(OCT) using a sweep-source laser whose center wavelength is 1310 nm and a probe of hand-held type. The developed hand-held probe targets to diagnose the middle ear, so it is miniaturized for ease and convenience of control. For the first time, we performed in-vivo clinical experiments on tympanic membrane(TM) perforation patients not reported from previous studies about OCT. The high-resolution sectional images of tympanic membrane perforation can be obtained. There aren't many studies about diagnostic instrument of the middle ear and diagnosis with sectional image of the middle ear, so the developed OCT system and hand-held probe are applicable to tympanic membrane perforation and other pathologic diagnosis in the middle ear.

Preliminary Analysis of Delta-V Requirements for a Lunar CubeSat Impactor with Deployment Altitude Variations

  • Song, Young-Joo;Ho, Jin;Kim, Bang-Yeop
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.257-268
    • /
    • 2015
  • Characteristics of delta-V requirements for deploying an impactor from a mother-ship at different orbital altitudes are analyzed in order to prepare for a future lunar CubeSat impactor mission. A mother-ship is assumed to be orbiting the moon with a circular orbit at a 90 deg inclination and having 50, 100, 150, 200 km altitudes. Critical design parameters that are directly related to the success of the impactor mission are also analyzed including deploy directions, CubeSat flight time, impact velocity, and associated impact angles. Based on derived delta-V requirements, required thruster burn time and fuel mass are analyzed by adapting four different miniaturized commercial onboard thrusters currently developed for CubeSat applications. As a result, CubeSat impact trajectories as well as thruster burn characteristics deployed at different orbital altitudes are found to satisfy the mission objectives. It is concluded that thrust burn time should considered as the more critical design parameter than the required fuel mass when deducing the onboard propulsion system requirements. Results provided through this work will be helpful in further detailed system definition and design activities for future lunar missions with a CubeSat-based payload.

A Study on Thermal Deformation Compensation in the Molding of Aspheric Glass Lenses (비구면 유리렌즈 열변형 보정에 관한 연구)

  • Lee, Dong-Kil;Kim, Hyun-Uk;Cha, Du-Hwan;Lee, Hak-Suk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.5
    • /
    • pp.22-26
    • /
    • 2010
  • Recently, due to the tremendous growth of media technology, demands of the aspheric glass lens which is a high-performance and miniaturized increase gradually. Generally, the aspheric glass lens is manufactured by Glass Molding Press (GMP) method using tungsten carbide (WC) mold core. In this study, the thermal deformation which was occurred by GMP process was analyzed and applied it to compensate the aspheric glass lens. The compensated lens was satisfied that can be applied to the actual specifications.

Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (I): Optimal Design of Ring-shaped Flab Valve Module (바이오용 압전디스크방식 마이크로 펌프 설계 및 제작(I) -링형 플랩밸브 모듈의 최적설계-)

  • Kim, Hyung-Jin;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.355-361
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, it has some intrinsic disadvantages such as backward flow, pulsation of flow, low repeatability and producibility, and high cost. To overcome these limitation, a PZT disc actuated micro pump including a novel ring-shaped multi-flap check valve is introduced. To enhance the performance of the micro pump, the static behaviour of flap valve module and the micro fluidic behavior of fluids are numerically modelled and analyzed. As results of the numerical analysis, the optimal dimension and configuration of the ring-shaped multi flap valve are $1{\times}0.05$ mm and 2 (inlet side)${\times}1$ (outlet side) type. The obtained maximum flow rates and flow resolution are about 90 ml/min and 30 ${\mu}l$/stroke respectively.

Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (II): Optimal Design & Fabrication of Embedding-type PZT Module (바이오용 압전디스크방식 마이크로 펌프 설계 및 제작 (II) -임베드방식의 압전모듈의 최적설계 및 제작-)

  • Kim, Hyung-Jin;Chang, In-Bae;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.362-367
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, most of the conventional micro pumps still have some limitations to miniaturize their controller system and to obtain the sufficient back pressure which can rise over the inner pressure of human body or experimental animals. In this paper, to overcome these limitation, a new PZT disc and its controller were designed and fabricated to get the sufficient flowrate and the back pressure with guaranteeing embeddability of the controller into pumping body. The amplitudes of the disc deflections were as large as 40 ${\mu}m$ at 200 V - 100 Hz condition. As results of experiments, the flow rate and the back pressure increase when the frequency increases. The obtainable maximum flow rate and back pressure are 5.2 ml/min at 95 Hz and 13.14 kPa at 90 Hz respectively.