1 |
Kim, H. J., Seo, Y. H., and Kim, B. H., 2011, "Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-applications (I): Optimal Design of Ring-shaped Flab Valve Module," J. of KSMTE, Submitted.
|
2 |
Smits, J. G., 1990, "Piezoelectric Micropump with Three Valves Working Peristaltically," Sensors and Actuators A, Vol. 21-23, No. 1-3, pp. 203-206.
|
3 |
Lee, C. W., Song, J. Y., and Ha, T. H., 2007, "Control Platform Design of Micro Factory for Micro Pump," KSMTE spring conference, pp. 273-276.
|
4 |
Yang, X., Zhou, Z., Cho, H., and Luo, X., 2006, "Study on a PZT-actuated Diaphragm Pump for Air Supply for Micro Fuel Cells," Sensors and Actuators A, Vol. 130-131, pp. 531-536.
DOI
ScienceOn
|
5 |
Kan, J., Yang, Z., Peng, T., Cheng, G., and Wu, B., 2005, "Design and Test of a High-performance Piezoelectric Micropump for Drug Delivery," Sensors and Actuators A, Vol. 121, No. 1, pp. 156-161.
DOI
ScienceOn
|
6 |
Liua, G., Shen, C., Yang, Z., Cai, X., and Zhang, H., 2010, "A Disposable Piezoelectric Micropump with High Performance for Closed-loop Insulin Therapy System," Sensors and Actuators A, Vol. 163, No. 1, pp. 291-296.
DOI
ScienceOn
|
7 |
Cooney, C. G., and Towe, B. C., 2004, "A Thermopneumatic Dispensing Micropump," Sensors and Actuators A, Vol. 116, No. 3, pp. 519-524.
DOI
ScienceOn
|
8 |
Jun, D. H., Sim, W. Y., and Yang, S. S., 2007, "A Novel Constant Delivery Thermopneumatic Micropump using Surface Tensions," Sensors and Actuators A, Vol. 139, No. 1-2, pp. 210-215.
DOI
ScienceOn
|
9 |
Van de Pol, F. C. M., Van Lintel, H. T. G., Elwenspoek, M., and Fluitman, J. H. J., 1990, "A Thermopneumatic Micropump based on Micro-engineering Techniques," Sensors and Actuators A, Vol. 21, No. 1-3, pp. 198-202.
DOI
ScienceOn
|
10 |
Luo, A., and Xia, A., 2005, "A Novel Valve-less Synthetic-jet-based Micro-pump," Sensors and Actuators A, Vol. 122, No. 1, pp. 131-140.
DOI
ScienceOn
|
11 |
Bourouina, T., Bosseboeuf, A., and Grandchamp, J. P., 1997, "Design and Simulation of an Electrostatic Micropump for Drug-delivery Applications," J. Micromech. Microeng., Vol. 7, No. 3, pp. 186-188.
DOI
ScienceOn
|
12 |
Teymoori, M. M., and Abbaspour-Sani, E., 2005, "Design and Simulation of a Novel Electrostatic Peristaltic Micromachined Pump for Drug Delivery Applications," Sensors and Actuators A, Vol. 117, No. 2, pp. 222-229.
DOI
ScienceOn
|
13 |
Woias, P., 2005, "Micropumps-past, Progress and Future Prospects," Sensors and Actuators B, Vol.105, No. 1, pp. 28-38.
DOI
|
14 |
Havli'k, R., Kerkhoffs, W., Jiao, L. R., Schumacher, O., Reul, H., and Habib, N., 2001, "Intravascular Micropump for Augmented Liver Perfusion : First In Vivo Experience," Artificial Organs, Vol. 25, No. 5, pp. 392-394.
DOI
ScienceOn
|
15 |
Oshio, K., Watanabe, H., Song, Y., Verkman, A. S., and Manley, G. T., 2005, "Reduced Cerebrospinal Fluid Production and Intracranial Pressure in Mice Lacking Choroid Plexus Water Channel Aquaporin-1," FASEB J, Vol. 19, pp. 76-78.
|
16 |
Supertex Inc, n.d., viewed at 4 May 2009, .
|