• Title/Summary/Keyword: Mini Pump

Search Result 26, Processing Time 0.03 seconds

The Retention and Chemical Composition of NVOCs (Natural volatile organic compounds) in a Warm Temperate Forest (난대림의 NVOCs 잔존량 및 성분 특성)

  • Sujin, Jang;Dohyun, Ryu;Kiwan, An
    • Journal of Environmental Science International
    • /
    • v.31 no.11
    • /
    • pp.901-910
    • /
    • 2022
  • The aim of this study was to investigate the amount (i.e., retention volume) and chemical composition of Natural volatile organic compounds (NVOCs) across different sites in a temperate forest. The three forest sites that were considered include riparian zones (site 1), streams (site 2), and densely-canopied areas (site 3). From May to October 2021, a mini pump was used to measure the collected NVOCs. These measurements were conducted once a month, from 10:30 am to 11:30 am; these times encompass peak visitation times. In the tree layers of the site 1 and 2, Quercus acuta was dominant, whereas Camellia japonica dominated their subtree layers. On the other hand, the tree layer of site 3 was dominated by Castanopsis sieboldii, whereas Camellia japonica dominated its subtree layer. The retention volume and chemical composition of NVOCs was as follows: benzaldehyde (107.528ppm), α-pinene (37.868ppm), linalool (16.258ppm), eucalyptol (14.818ppm), and sabinene hydrate (14.679ppm). In particular, the retention volume of benzaldehyde decreased as temperature increased. In contrast, the retention volume of α-pinene increased as the temperature increased. The differences in forest topography across the studies sites were in the following order: riparian area> forest area> stream area.

Evacuation characteristic measurement of anti-suck back centering by mini vacuum system (미니 진공시스템을 이용한 역류방지 센터링의 배기 특성 측정)

  • Hong, Gwang-Gi;Go, Seok-Il;Do, U-Ri;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.255-256
    • /
    • 2009
  • The anti suck back centering (ASBC) for preventing backflow of oil for oil rotary pump was designed in the power failure. To evaluate the evacuation characteristics, we manufactured the mini vacuum system, personal computer, AD converter (National instrument, NI-6009), and automatic controller with touch panel for a basis. In this study, we measured the evacuation characteristics of ABSC and analyzed the flow field of viscous flow regime using a commercial software, CFD-ACE+. Also, the leakage of the advaced ASBC for leveling was measured.

  • PDF

Development of the Novel Dry and Wet Deposition Collector (새로운 건성 및 습성 침착 채취기의 개발)

  • 이병규;이채복
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

Sediment Trap Studies to Understand the Oceanic Carbon Cycling: Significance of Resuspended Sediments (퇴적물 트랩을 이용한 해양 탄소 순환 연구 동향: 재부유 퇴적물의 중요성)

  • KIM, MINKYOUNG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.2
    • /
    • pp.145-166
    • /
    • 2021
  • For several decades, sediment traps have served as one of the key tools for constraining the biological carbon pump (BCP), a process that vertically exports particulate organic carbon (POC) and associated biogenic materials from marine primary production in surface waters to the deep ocean interior. In this paper, I introduced the general methods, the current status of global sediment trap studies, and importance of it to understand the deep ocean carbon cycling. Recent studies suggest that sinking POC in the deep ocean are more complex and spatio-temporally heterogeneous than we considered. Especially researches those studied resuspended and laterally transported particles are presented. Researches that used organic (radiocarbon; 14C) and inorganic (Al) tracers to understand the oceanic POC cycling and the significance of resuspended particles are reviewed, and the importance of radiocarbon study by using MICADAS (Mini radioCarbon Dating Systems) is emphasized.

Experimental Study on Characteristics of Evaporation Heat Transfer and Oil Effect of $CO_2$ in Mini-channels (미세채널 내 이산화탄소의 증발 열전달 특성 및 오일의 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.16-22
    • /
    • 2009
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a mini-channels were performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($300{\sim}800kg/m^{2}s$), heat fluxes($10{\sim}40kW/m^2$) saturation temperatures($-5{\sim}5^{\circ}C$), and PAG oil concentration(0, 3, 5wt%). The variation of the heat transfer coefficient was different according to the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

Thermal Performance of Cooling System for a Laptop Computer Using a Boiling Enhancement Microstructure (비등 촉진 마이크로 구조물을 이용한 휴대용 컴퓨터 냉각시스템의 열성능에 관한 연구)

  • Cho, N.H.;Jeong, W.Y.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2043-2052
    • /
    • 2008
  • The increasing heat generation rates in CPU of notebook computers motivate a research on cooling technologies with low thermal resistance. This paper develops a closed-loop two-phase cooling system using a micropump to circulate a dielectric liquid(PF5060). The cooling system consists of an evaporator containing a boiling enhancement microstructure connected to a condenser with mini fans providing external forced convection. The cooling system is characterized by a parametric study which determines the effects of volume fill ratio of coolant, existence of a boiling enhancement microstructure and pump flow rates on thermal performance of the closed loop. Experimental data shows the optimal parametric values which can dissipate 33.9W with a film heater maintained at $95^{\circ}C$.

  • PDF

Chordae Tendineae Approximation Technique for Severe Tricuspid Regurgitation with Severe Leaflet Tethering Using a Totally Endoscopic Beating-Heart Strategy: A Case Report

  • Dong Hee Jang;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.56-58
    • /
    • 2023
  • Untreated severe tricuspid regurgitation (TR) is associated with poor outcomes. Functional TR occurs secondary to dilatation of the annulus and tethering of the leaflets. Ring annuloplasty alone can correct most cases, but is insufficient in cases of severe annular dilatation due to severe leaflet tethering. In such cases, a tricuspid edge-to-edge technique may be an option. However, stitching of the leaflet tips alone is likely to result in tearing of the leaflets. Approximation of the durable chordae tendineae is considered helpful for this problem. Herein, we present the case of a 39-year-old man who had undergone open-heart surgery for acute type A aortic dissection 13 months earlier. A right mini-thoracotomy approach with a beating-heart strategy was used, which did not require unnecessary pericardial adhesiolysis and dissection. This technique had the advantage of reducing the operation time and the risk of bleeding. To summarize, we present a case of tricuspid valve repair in a high-risk patient with severe leaflet tethering that was successfully managed using these methods.

Delayed Intraventricular Nogo Receptor Antagonist Promotes Recovery from Stroke by Enhancing Axonal Plasticity

  • Kim, Tae-Won;Lee, Jung-Kil;Joo, Sung-Pil;Kim, Tae-Sun;Kim, Jae-Hyoo;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.2
    • /
    • pp.130-135
    • /
    • 2006
  • Objective : After ischemic stroke, partial recovery of function frequently occurs and may depend on the plasticity of axonal connections. Here, we examine whether blockade of the Nogo/NogoReceptor[NgR] pathway might enhance axonal sprouting and thereby recovery after focal brain infarction. Methods : Adult male Sprague Dawley rats weighing $250{\sim}350g$ were used. Left middle cerebral artery occlusion[MCAO] was induced with a intraluminal filament. An osmotic mini pump [Alzet 2ML4, Alza Scientific Products, Palo Alto, CA] for the infusion of NgR-Ecto[310]-Fc to block Nogo/NgR pathway was implanted 1 week after cerebral ischemia. Prior to induction of ischemia, all animals received training in the staircase and rotarod test. Two weeks after biotin dextran amine injection, animals were perfused transcardially with PBS, followed by 4% paraformadehyde/PBS solution. Brain and cervical spinal cord were dissected. Eight coronal sections spaced at 1mm intervals throughout the forebrain of each animal with cresyl violet acetate for determination of infarction size. Images of each section were digitized and the infarct area per section was measured with image analysis software. Results : Histological examination at 11 weeks post-MCAO demonstrates reproducible stroke lesions and no significant difference in the size of the stroke between the NgR[310]Ecto-Fc protein treated group and the control group. Behavioral recovery is significantly better and more rapid in the NgR-Ecto[310]-Fe treated group. Blockade of NgR enhances axonal sprouting from the uninjured cerebral cortex and improves the return of motor task performance. Conclusion : Pharmacological interruption of NgR allows a greater degree of axonal plasticity in response this is associated with improved functional recovery of complicated motor tasks.

Studies on Solvent Sublation of Trace Heavy Metals by Continuous Flow System as Ternary Complexes of 1,10-Phenanthroline and Thiocyanate Ion

  • Kim, Young-Sang;Choi, Yoon-Seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1775-1780
    • /
    • 2003
  • A continuous flow system has been developed to determine trace Cu(II), Mn(II), Ni(II) and Zn(II) in a large volume of water samples by a solvent sublation technique. The mixed solution of 1,10-phenanthroline(phen) and thiocyanate ion was used as ligands for the formation of their ternary complexes. The continuous system was constructed in this laboratory with a peristaltic pump, a mini shaker, three mixing bottles and a flotation cell by connecting each part with a polyethylene tube. The flotation conditions such as the flow rate of sample solution and the injection rates of ligand, buffer and surfactant solutions have been investigated to obtain the best sublation efficiencies. Each solution flowed into the flotation cell through each polyethylene tube by the peristaltic pumps. The ternary complexes were floated and extracted into MIBK in a flotation cell of 2 L by bubbling a nitrogen gas. The absorbances of extracted analytes in MIBK were directly measured by graphite furnace-AAS. The concentrations of 1,10-phenanthroline and thiocyanate ion were $2.6\;{\times}\;10^{-3}$ M and $2.3\;{\times}\;10^{-2}$ M in the mixed solution, respectively. The pH of sample solution was adjusted to 5.0 with a buffer solution and 1%(m/v) sodium lauryl sulphate solution was added as a surfactant to support the effective flotation of the complexes. The $N_2$ gas was bubbled at 30 mL/min for 90 minutes for 20 L of sample. Reproducible results of less than 10% RSD and recoveries of 80-120% could be obtained in real samples.