• Title/Summary/Keyword: Middle and High School Facilities

Search Result 170, Processing Time 0.024 seconds

The Study on the Situation of Exterior and Interior Colour of School Facilities for Improvement in Educational Environment-Focused on Busan- (교육환경 개선을 위한 학교시설 내 · 외부 색채 현황조사연구 -부산지역을 중심으로-)

  • Kim, Ki-Hwan;Kim, Eun-Jung;Lee, Tae-Soo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.2 no.1
    • /
    • pp.29-48
    • /
    • 2002
  • This study is for achievement of the expected aim on establish principle colour scheme of exterior and interior school facilities. Also this study aims to utilization of the data which is need for educational colour scheme of school facilities basically. The result of this study is as follows; 1) Domestic case study in primary school colour value distributed middle and high level between 5R and 6Y, the case study of foreign colour scheme distributed low and middle level. 2) Domestic case study in middle school facilities colour scheme distributed same colour of R, YR and the chroma distributed between 1 to 4. 3) The case study of domestic and foreign high school colour scheme distributed that in cases of domestic the colour scheme distributed very loose style and foreign cases distributed same colour of RP to YR with middle and high level of value and low chroma. 4) Exterior school facilities colour scheme distributed in Busan is that N~5GY(value 8~9 and chroma 0~8) in main school building skin material colour, 0~4 value and 7.5~9 chroma in assistant skin material colour. 5) Interior school facilities colour scheme distributed same colour of B, BF, PB, RP, N, YR in class room and open classroom in school mainly.

  • PDF

A Study on Spatial Composition of Educational Facilities by Design Process Model (설계과정 모델별 교육시설 공간구성에 관한 연구)

  • Yang, Kum-suek
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.5 no.2
    • /
    • pp.1-13
    • /
    • 2006
  • The purpose of this study is to clarify the actual conditions of spatial composition of educational facilities by design process model. This article discuses about the characteristics of the floor plan composition and the site plan patterns of 49 middle and high schools in gyeongnam province. The results of this study are summarized as follows; 1) Comparing to traditional middle and high school facilities, it occurs various types of plane and the area is somewhat expanded in the school with same class size, however, it needs to improve facility standards in its reality to deal with the change of future educational environment actively. 2) Spatial composition of educational facilities should functionally designed considering that the characteristics of design process model. In facilities arrangement of middle and high schools, it shows diverse forms of arrangement from existing uniform straight type, however, most of schools do not being against the simple in their external space. Therefore, it requires an expansion of space siæ and facilities for the change of school life outside class.

  • PDF

A Study on the Actual Conditions of External Space of Middle and High Schools in Gyeongnam Area (경남지역 중·고등학교의 외부공간 구성 실태에 관한 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.9 no.2
    • /
    • pp.29-40
    • /
    • 2007
  • The purpose of this study is to clarify the actual conditions of external space of middle and high schools in Gyeongnam Area. This article discuses about the characteristics of the external space and the site plan type of 49 middle and high schools in Gyeongnam Area. The result of analysis about site plan type, composition state of external space and area ratio of its composition of each middle and high school facilities are as follows: In facilities arrangement of middle and high schools, it shows diverse forms of arrangement from existing uniform straight type, however, most of schools do not being against the simple in their external space. Especially, for the area is small in the composition of external space, a playground is only under $50m{\times}80m$ and outdoor learning space or resting space is not secured sufficiently. Therefore, it requires an expansion of space size and facilities for the change of school life outside class.

  • PDF

A Study on Space Satisfaction and Characteristic of Student's Moving Route of Departmentalized Class System High school in Chungbuk Area (충북지역 교과교실제 고등학교의 공간 만족도 및 학생 이동 동선 특징 조사연구)

  • Jung, Jin-Ju
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.4
    • /
    • pp.25-34
    • /
    • 2011
  • On former days, school has realized as "where teach", but development of a technology and change of paradigm are changing school as "where study". This is meaning that student is more important and be considered than others when make school environment. Due to continuous investment of national level in several decades, in our elementary school's facilities and environment, when compare with advanced nations that we know that have come to the fairly high level. But, it is not really certainly in middle school and high school. Than the reason is, 'College entrance examination' is prior than other certain values in occasion of high school especially, and we ask a question in return whether have persuaded ourselves that school facilities and environment may change later. It is hard to find more important thing than the proposition in fact on present society. However, it is that society and facilities that can correspond to fast change of paradigm, change of curriculum, learner's change and environment have to be changed in middle school and high school now. Departmentalized Class System that applies in national middle and high school now can become an opportunity that can improve school facilities and environment of middle and high school. In such background, I studied space satisfaction and student's moving route and pattern characteristic of Departmentalized Class System high school in Chungcheongbuk-do area. And this study aims at supply the data about efficient Departmentalized Class System School's facilities plan and space use which can meet on request of students.

A Comparison Study on Spatial Rearrangement for the Departmentalized Classroom System in Middle and High School in the Rural Area (농촌지역 중·고등학교의 교과교실제를 위한 공간 재배치 특성)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.3
    • /
    • pp.37-44
    • /
    • 2014
  • This study is to clarify the actual conditions of the floor plan of middle and high schools in the rural area. Recently, many middle school and high school are remodeling the buildings and facilities based on the departmentalized classroom system. This study, through analyzing on 4 remodeling cases of middle and high schools in gyeongnam. This article discuses about the basic characteristics of the plan composition and the education programs of 4 schools. This study is showing the variation before and after remodeling and space organization types. The results of this study are summarized as follows; Home-room and home-base should be more faithfully. Various common space is needed to comfortable school life of students. In case of side corridor type plan, moving path is much needed. Sample schools took much more spaces of home base than before. This article discusses about the basic characteristics of the floor plan and the actual condition of the school facilities.

Influence of School Environment Awareness on Subjective Feeling of Happiness in Adolescents (학교 환경에 관한 인식이 청소년들의 주관적 행복감에 미치는 영향)

  • Hyunju, Park
    • Journal of the Korean Society of School Health
    • /
    • v.35 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the effects of being aware of the physical and psychosocial environment of the school on subjective feeling of happiness in Korean middle and high school students. Methods: The data of "Health and lifestyle Survey (2019)" conducted by the National Youth Policy Institute were analyzed after receiving approval though the website. A total of 5,311 middle and high school students were included in the analysis. Descriptive statistics, t-test, one-way ANOVA, pearson correlation, and multiple regression analysis were executed using SAS 9.4. Results: The mean score of subjective feeling of happiness was 6.92±0.56 out of 10. From the univariate analysis, the more positive the perception of the physical school environment was, such as classrooms, restrooms, exercise facilities, catering facilities, health facilities, other school facilities and school uniform, the higher the subjective feeling of happiness was (p for all <.001). In addition, the psychosocial environment of the school was significantly related to the happiness of adolescents (p<.001). After controlling for gender, school level, school grade, socio-economic status, and stress, positive perception of classrooms (B=0.04, p<.001), catering facilities (B=0.01, p=.021), health facilities (B=0.08, p<.001), and the psychosocial environment of the school (B=0.18, p<.001) was significantly associated with happiness of the students. Conclusion: Positive perception of the school environment was found to increase happiness in adolescents. Therefore, efforts should be made to make classrooms, catering facilities, and health facilities a pleasant space as well as to create a school atmosphere that values health.

A study on Teacher's Work Space in Middle and High School - Focus on Plan Based Department System Management in Middle and High School - (중·고등학교의 교사업무공간에 관한 연구 - 교과교실형 설계기반 중·고등학교를 중심으로 -)

  • Seo, Boong-Kyo;Kwak, Jun-Hyuck
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.1
    • /
    • pp.23-32
    • /
    • 2014
  • Aim of this research is suggesting a satisfied studying space for lecturer, student and curriculum by abstraction of improvement plan which based on investigation and analysis of the space that teacher is using in lecturer and study support facility in school which managed in 'Department system'. This research focused on analyse of teacher's laboratory, teacher's room, and common room in middle and high school which managed and designed by 'Department system' and registered on 'Seoul office of education' and designed in management of department system between 2009 and 2012. With these process, a conclusion of this research is as in the following. Firstly, plan of teachers' private place which is efficient and stable is required through to get out of module which can cover subject band and grade band. Secondly, we have to focus on size of teachers' convenience facilities for convenience or official usage, movement radius, and improvement of working environments. Thirdly, 'Subject type teachers' laboratory' which organized by teachers who teach same subject is more efficient than 'Task type laboratory' which organized by teachers who working on same task for management of school. In fourth, 'Task type teachers' laboratory' arranged regardless with teachers' class room to teach, and it makes lack of connectivity between teacher and class room.

An Analysis on Layout Patterns and their Trends in the Prizewinners of Elementary.Middle.High School Design Competitions (초.중.고등학교 현상설계 당선안에 나타난 배치 계획 요소 및 경향 분석)

  • Lee, Jung-Woo;Kim, Hyung-Jin
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.3
    • /
    • pp.3-12
    • /
    • 2012
  • Owing to generalization of design competitions since 1990s, various design methods was tried in elementary middle high school design competitions. Therefore, to analyze design characteristics of elementary middle high school is very meaningful. In this context, this study is the most important purpose for analyzing layout plans and their trends in prizewinners of elementary middle high school design competitions and for furnishing basic datum for next school design. The result of this study is following : (1) The layout patterns of school buildings are classified into 12 types. (2) Entrance design is divided into 6 types(structure, column and wall, open, half structure, general, and mixed type). (3) Square design is grouped into 7 types. (4) Pedestrian mall is sorted out 6 types(straight lineal, curve, curve and square, straight lineal and curve, and straight lineal and curve and square type). (5) Entrance types of vehicle and pedestrian are classified into 4 types(parallel, ㅡ separation, ㄱ separation, and opposite separation type) Analysis shows that the best applying for layout patterns of school buildings is ㄷ type and ㅌ type, for entrance design is structure type, for square design is ${\square}$ type and ${\bigcirc}$ type, for pedestrian mall is straight lineal and square type, and for entrance types of vehicle and pedestrian is parallel type.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.510-515
    • /
    • 2007
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows ; 1) On the whole, typical rates of water-use was founded out 15 L / stu. d in pirmary school, 10 L / stu. d in middle school and 30L / stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking pick load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

  • PDF