• Title/Summary/Keyword: Microwave Extraction

Search Result 170, Processing Time 0.033 seconds

The Analysis of DC and AC Current Crowding Effects Model in Bipolar Junction Transistors Using a New Extraction Method (새로운 측정방법을 이용한 바이폴라 트랜지스터에서의 직류 및 교류 전류 편중 효과에 관한 해석)

  • 이흥수;이성현;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.46-52
    • /
    • 1994
  • DC and AC current crowding effects for microwave and high speed bipolar transistors are investigated in detail using a new and accurate measurement technique based on Z-parameter equationa. Using the new measurement technique dc and ac current crowding effects have been explained clearly in bipolar junction transistors. To model ac crowding effects a capacitive element defined as base capacitance (C$_b$), called ac crowding capacitance is added to base resistance in parallel thereby treating the base resistance(R$_b$) as base impedance Z$_b$. It is shown that base resistance decreases with increasing collector current due to dc current crowding and approaches to a certain limited value at high collector current due to current crowding and approaches to a certain limited value at high collector currents regardless of the emitter size. It is also observed that due to ac current crowding base capacitance increases with increasing collector current. To quantigy the ac crowding effects for SPICE circuit simulation the base capacitance(C$_b$) including the base depletion and diffusion components has been modeled with an analytical expression form.

  • PDF

Determination of polycyclic aromatic hydrocarbons in processed foods (가공식품 중 다환방향족탄화수소 분석)

  • Hu, Soo-Jung;Jin, Sun-Hee;Lee, Kwang-Ho;Choi, Dong-Mi
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.196-204
    • /
    • 2010
  • In this study, the following concentrations of some PAHs (Polycyclic Aromatic Hydrocarbons) were investigated; [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in processed foods (n=165) and cooked meats (n=45) and established the analytical method by characteristics of processed foods. The methodology involved extraction (alkali digestion, liquid-liquid extraction, microwave extraction), clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD (High Performance Liquid Chromatography/Fluorescence Detector). The recovery of overall method for 8 PAHs spiked into these products ranged from 92 to 103%. The mean level of detected foods was found to be benzo(b)fluoranthene $0.9\;{\mu}g/kg$ in smoked salmon, benzo(b)fluoranthene $1.0\;{\mu}g/kg$, benzo(k)fluoranthene $0.3\;{\mu}g/kg$, benzo(a)pyrene $0.9\;{\mu}g/kg$ in dried banana, benzo(b)fluoranthene $0.2\;{\mu}g/kg$, benzo(k)fluoranthene $0.1\;{\mu}g/kg$, benzo(a)pyrene $0.2\;{\mu}g/kg$ in smoked chicken, benzo(b)fluoranthene $1.3\;{\mu}g/kg$, benzo(k)fluoranthene $0.3\;{\mu}g/kg$, benzo(a)pyrene $0.9\;{\mu}g/kg$ in charcoal grilled pork, respectively.

Studies of separation and quantitation for selenium species in food (식품중의 셀레늄 화학종의 분리 및 정량연구)

  • Jang, Hee-Young;Min, Hyungsik;Lee, Jonghae;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.182-189
    • /
    • 2013
  • The purpose of this research is to separate and quantitate selenium species in some food samples with HPLC-ICP-MS. Cation exchange chromatography showed efficient separation only for inorganic Se species while reversed phase ion pair chromatography showed good separation for both inorganic and organic Se species. $C_8$ column ($Symmetryshield^{TM}\;RP_8$, 3.5 ${\mu}m$, $4.6{\times}150$ mm) was used with optimum condition of 5% methanol mobile phase, 0.05% of nonafluorovaleric acid ion pairing reagent. Five standard Se species of Se(IV), Se(VI), SeCys(selenocystein), SeMet(selenomethionine) and Se-M-C(seleno methyl cystein) were separated successfully under the optimum condition (mobile phase; 5% methanol, ion-pairing reagent; 0.05% nonafluorovaleric acid, flow rate; 0.9 mL $min^{-1}$). To extract Se species, microwave assisted and enzyme-assisted extraction methods were studied. In enzyme-assisted extraction method, protease I for garlic, protease I plus trypsin for pork and mackerel, and protease XIV for tuna showed the best extraction efficiency. With the optimum condition for each sample, it was found that mostly inorganic Se, SeCys and SeMet are present in the sample studied ranging from few ${\mu}g$ $g^{-1}$ to few tens of ${\mu}g$ $g^{-1}$.

Matrix effect on the Determination of Inorganic Priority Pollutants in Sludges (오니 시료중의 무기 Priority Pollutants의 분석 과정에 미치는 매질의 영향)

  • Lee, Huk-Hee;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.297-304
    • /
    • 1998
  • The three analysis methods, EPA method 3050, the method offered by Ministry of Environment in Korea, and modified method corrected in this laboratory, were studied to investigate the effect of matrix on the analysis of inorganic priority pollutants. 7 inorganic priority pollutants(Ni, Cr, Cu, Zn, Pb, Cd, Hg) were spiked to the plating, leather, paper, electric, and dye sludges. Mean recovery of the elements except Hg was 95.5% when the procedure of EPA method was applied. However, recovery by the two other extraction methods showed 11.1% and 27.7%, respectively. Digestions were done by MDS (microwave digestion system) and $HNO_3+HClO_4$ methods. To study organic and inorganic matrix effect, samples were made by adding triethanol amine as a organic matrix and $FeCl_3{\cdot}6H_2O$+$AlCl_3{\cdot}6H_2O$ as a inorganic matrix, respectively. The extracts were analyzed by AAS and HG-AAS. Mean recovery of the elements by the $HNO_3+HClO_4$ procedure, except Hg, gave better result than that of the MDS method. Mean recovery of elements was decreased when organic and inorganic matrices were added in the sludge samples. The procedure of MDS and $HNO_3+HClO_4$ digestion gave higher recoveries than that of direct analysis. In general, the results of the studies showed a significant matrix effect on the inorganic priority pollutants analysis in sludges.

  • PDF

Risk Assessment of Arsenic in Agricultural Products (농산물 중 비소 위해평가)

  • Choi, Hoon;Park, Sung-Kug;Kim, Dong-Sul;Kim, Mee-Hye
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.266-272
    • /
    • 2010
  • The present study was carried out to assess exposure & risk for Korean by total and inorganic As intake through agricultural products. Total arsenic analysis was performed using microwave device and ICP-MS. 50% MeOH extraction and anion-exchange HPLC-ICP-MS method has been used to determine arsenic species. 329 samples covering 20 kinds of agricultural products were collected from various retail outlets and markets across Korea. The concentration of total As was in the range of 0.001~0.718 mg/kg, while inorganic and organic arsenic species in all samples was not determined. For risk assessment, probable daily intake was calculated and compared with provisional tolerable weekly intake (PTWI, 15 ${\mu}g$/kg b.w./week for inorganic arsenic) established by JECFA. The median daily exposure to total and inorganic As by intake of agricultural products except rice was ranged 0.0002~0.012, 0.0001~0.001 ${\mu}g$/kg b.w./day, corresponding to 0.01~0.5%, 0.002~0.1% of PTWI, respectively. The median level of total and inorganic As intake through rice was 0.603 and 0.041 ${\mu}g$/kg b.w./day, and 28.1% and 1.9% of PTWI, respectively. Therefore, the level of overall exposure to arsenic for Korean through agricultural products was below the recommended JECFA levels, indicating of least possibility of risk.

Determination of new antifouling agents in seacoasts in Korea by gas chromatography-mass spectrometry (GC/MS를 이용한 한국연안의 새로운 방오제 분석)

  • Lee, Seongeon;Won, Hoshik;Lee, Dongsup
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.459-473
    • /
    • 2008
  • Antifouling agents including tributyltin (TBT) compound and its derivatives have been used for many years, but the usage of TBT in Korea was legally restricted in 2003, due to its significant environmental impact. Following this, many new alternative antifouling agents have been used. In this experiment, four major antifouling agents were selectively analyzed to study their release in seawater and tidal flats on the Korean Peninsula. These new antifouling agents were extracted from the seawater and tidal flats using a liquid-liquid extraction method and microwave extraction, respectively. The measured concentrations of Irgarol 1051, Sea-Nine 211, Dichlofluanid and Chlorothalonil ranged from N.D.$-23.80ng/{\ell}$, N.D.$-15.30ng/{\ell}$, N.D.$-61.69ng/{\ell}$ and N.D.$-4.19ng/{\ell}$ in the seawater samples and from N.D.-159.45 ng/g, N.D.-476.57 ng/g, N.D.-59.79 ng/g and N.D.-21.27 ng/g in the tidal flat samples, respectively. Interestingly, these new antifouling agents were not detected in any area in the tidal flats at Pusan, whereas a certain amount of them was found in the seawater.

Analysis on Patent Trends in Nonthermal Processing Technologies for Medicinal Herbs (한약재 가공 기술의 특허 동향 연구 - 비가열 가공 기술을 중심으로 -)

  • Kim, Kyoung Shin;Kim, Sung Gu;Chae, Suhn Kee;Kim, Byoung Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2013
  • The purpose of this study was to analyze the patent application trend in the processing technology for medicinal herbs. Recently, in processing technology for medicinal herbs, experimental researches have frequently been published through papers in journals. However, the research results about the patent area were fewer than the others. We tried to analyze the patent application trend in nonthermal processing technologies for medicinal herbs by country as Korea, Japan, U.S.A. and Europe. The detailed technologies consisted of pulsed electric field, oscillatory magnetic field, intense pulsed light, ultrasonification, high hydrostatic pressure, microwave, radiation, Ohmic heating, and supercritical extraction. As a result we found that patents of nonthermal processing technologies has been growing steadily in quantity from 1980s and growing quickly since 2000s. The number of patent in Korea is larger than others as making up 70% in that whole. The number of patent in ultrasonification field was larger than others in portfolio analysis. Patent application trend in nonthermal processing technologies for ingestion occupies high share compared to other usage applications. In conclusion, patent trends of nonthermal processing technologies for medicinal herbs belong to the period in the development.

Determination of Cadmium, Copper, Lead, Nickel, and Zinc in Sediments by ID-ICP/MS (동위원소희석 질량분석법에 의한 저니토 중의 카드뮴, 구리, 납, 니켈, 아연의 정량)

  • Cho, Kyung-Haeng;Park, Chang-Joon;Suh, Jung-Kee;Han, Myoung-Sub
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.297-303
    • /
    • 2000
  • Isotope-dilution inductively coupled plasma mass spectrometry was used to determine trace amounts of Cd, Cu, Pb, Ni and Zn in sediment. Sediment samples were dissolved by microwave digestion with addition of mixed acid ($HNO_3$, HF and $HClO_4$). Lead was determined after separation of alkaline and alkaline earth metals by an ammonium pyrrolidenedithiocarbarmate (APDC) solvent extraction. The other elements were determined after separation of iron, tin and titanium by hydroxide precipitation. Recovery efficiency of the analyte elements was not satisfactory, but most of matrix elements causing the isobaric interference could be effectively eliminated by the separation. Good agreement was achieved with the certified values in the analysis of the two sediment reference materials.

  • PDF

Implementation of a very small 13.56[MHz] RFID Reader ensuring machine ID recognition in a noise space within 3Cm (3Cm 이내의 잡음 공간 속 기계 ID 인식을 보장하는 초소형 13.56[MHz] RFID Reader의 구현)

  • Park, Seung-Chang;Kim, Dae-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.10 s.352
    • /
    • pp.27-34
    • /
    • 2006
  • This paper has implemented a very small($1.4{\times}2.8[Cm^2]$) 13.56[MHz] RFID reader ensuring machine ID recognition correctly in a noise space of Tag-to-Reader within 3Cm. For operation of the RFID system, at first, this paper has designed the loop antenna of a reader and the fading model of back-scattering on microwave propagation following to 13.56[MHz] RFID Air Interface ISO/IEC specification. Secondly, this paper has proposed the automatically path selected RF switching circuit and the firmware operation relationship by measuring and analyzing the very small RFID RF issues. Finally, as a very small reader main body, this paper has shown the DSP board and software functions made for extraction of $1{\sim}2$ machine ID information and error prevention simultaneously with carrying of 13.56[MHz] RFID signals that the international standard specification ISO/IEC 18000-3 defined.

Experimental Extraction of Effective Permittivity on the Structures of Coplanar Waveguides (코프래너 도파로 구조에서 S-파라메터를 이용한 유효유전상수 실험적 도출)

  • 지용
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.11
    • /
    • pp.15-20
    • /
    • 2004
  • This paper proposed a very simple method of extracting an effective permittivity from the data of scattering parameters measured on the transmission line of coplanar waveguides in the frequency range of microwave or millimeter waves. This is an extracting method of an effective permittivity $\varepsilon$$_{eff}$ in the case of $\beta$$\ell$ =n$\pi$ (n=integer), where the value of S$_{11}$ changes abruptly following the operating frequency. The experimental value of the effective permittivity $\varepsilon$$_{eff}$ on a dielectric substrate of Rogers 4003$^{TM}$ material of $\varepsilon$$_{r}$ =3.38 showed the value of 2.042, which differs in the error of -3.4% to 8% from those calculated from the previously reported formulae. This result showed that the measurement method was very simple, as well as applied directly to the fabricated circuit patterns, even though the circuit patterns might be complicated or on the substrate of different dielectric materials.s.als.