• Title/Summary/Keyword: Microtensile Bond Strength

Search Result 107, Processing Time 0.027 seconds

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

THE EFFECTS OF COLLAGENASE AND ESTERASE ON THE MICROTENSILE BOND STRENGTH IN DENTIN BONDING (상아질 접착에서 collagenase와 esterase가 미세인장결합강도에 미치는 영향)

  • Jung, Young-Jung;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.285-291
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of collagenase and esterase on the microtensile bond $strength({\mu}TBS)$ in dentin bonding. After resin composites were bonded to occlusal dentin. ${\mu}TBS$ specimens were formed and stored in PBS, collagenase, or esterase solution After 4-week storage, ${\mu}TBS$ was determined and, the results were as follows : 1. ${\mu}TBS$ values of Single Bond 2 were lower than those of Clearfil SE Bond for all storage medium (p<0.05). 2. In Single Bond 2 group, collagenase solution lowered bond strength more than PBS and esterase solution (p>0.05). 3. In Clearfil SE Bond group, esterase solution lowered bond strength more than PBS(p>0.05). Collagenase solution lowered bond strength more than esterase solution(p>0.05) and PBS(p<0.05).

  • PDF

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITION IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 1급 와동에서 와동벽 위치에 따른 microtensile bond strength 비교 연구)

  • Lee, Hyeon-Heon;Jung, Tae-Ryun;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.693-698
    • /
    • 2006
  • In Class I cavity, the highest C-factor could be obtained and it means the highest polymerization shrinkage stress. In this study, high C-factor model was designed. The pulpose of present study was to determine differences of Microtensile bond strength (MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Twenty clean mandibular 2nd primary molars were randomly divided into two groups Different composite Resins (Filtek Z250, 3M ESPE & Filtek Supreme, 3M ESPE) were bulk filled and photo cured. Axial wall specimens and pulpal specimens were prepared at the same teeth, All specimens were divided into 4 groups and MTBS were evaluated. Group ZP : Filtek Z250-Pulpal wall Group ZA : Filtek Z250-Axial wall Group SP : Filtek Supreme - Pulpal wall Group SA : Filtek Supreme - Axial wall The results were as follows: 1. Mean MTBS of ZP & ZA and SP & SA were significantly different(p<.001). 2. There was no significant difference between MTBS of ZP & SP and ZA & SA.

  • PDF

THE EFFECT OF DELAYED COMPOSITE RESIN FILLING ON MICROTENSILE BOND STRENGTH (복합레진의 지연충전이 미세인장 결합강도에 미치는 영향)

  • Park, Hyun-Sik;Cho, Young-Gon;Park, Byung-Cheul;Kim, Jong-Uk;Choi, Hee-Young;Kim, Jong-Jin;Jin, Cheul-Hee;Yoo, Sang-Hoon;Ki, Young-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.233-238
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of immediate or delayed composite resin filling on dentinal microtensile bond strength (${\mu}TBS$) after applied the adhesive. The coronal dentin of human third molars was exposed. Single-Bond or One-Step was applied on the dentin surfaces. and composite resin were constructed immediately (group 1) or 5min., 10min., 15min., 20min. and 30min. (groups 2-6) after an adhesive was applied. The specimens were sectioned and made bar-shaped. Each surface area of them was about $1\textrm{mm}^2$. The ${\mu}TBS$ test was performed by EZ test. The results were analysed by One-way ANOVA and Tukey's test at 95% significance level. The results suggested that the ${\mu}TBS$ of Single-Bond to dentin was decreased when the composite resin was constructed 20min. and 30min. after Single-Bond was applied. But the ${\mu}TBS$ of One-Step was not affected by delayed composite resin filling.

The effect of adhesive property on microtensile bond strength of human dentin

  • Kim, Hyoun-Jin;Hur, Bock
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.609-609
    • /
    • 2003
  • I. Objectives The purpose of this study was to evaluate the effect of adhesive property on microtensile bond strength and to determine the failure mode. II. Materials and Methods Flat occlusal dentin surfaces were prepared using low-speed diamond saw. The dentin was etched with 37% phosphoric acid. The following adhesives were applied to the etched dentin according to manufacturer's directions;Scotchbond Multi-Purpose in group 1, Primer&Bond NT in group 2, Scotchbond Multi-Purpose followed by Tetric-flow in group 3. After adhesive application, a cylinder of resin-based composite was built up the occlusal surface.(omitted)

  • PDF

Effect of chlorhexidine application on the bond strength of resin core to axial dentin in endodontic cavity

  • Kim, Yun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.207-214
    • /
    • 2012
  • Objectives: This study evaluated the influence of chlorhexidine (CHX) on the microtensile bonds strength (${\mu}TBS$) of resin core with two adhesive systems to dentin in endodontic cavities. Materials and Methods: Flat dentinal surfaces in 40 molar endodontic cavities were treated with self-etch adhesive system, Contax (DMG) and total-etch adhesive system, Adper Single Bond 2 (3M ESPE) after the following surface treatments: (1) Priming only (Contax), (2) CHX for 15 sec + rinsing + priming (Contax), (3) Etching with priming (Adper Single Bond 2), (4) Etching + CHX for 15 sec + rinsing + priming (Adper Single Bond 2). Resin composite build-ups were made with LuxaCore (DMG) using a bulk method and polymerized for 40 sec. For each condition, half of specimens were submitted to ${\mu}TBS$ after 24 hr storage and half of them were submitted to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using ANOVA and independent t-test at a significance level of 95%. Results: CHX pre-treatment did not affect the bond strength of specimens tested at the immediate testing period, regardless of dentin surface treatments. However, after 10,000 thermocycling, all groups showed reduced bond strength. The amount of reduction was greater in groups without CHX treatments than groups with CHX treatment. These characteristics were the same in both self-etch adhesive system and total-etch adhesive system. Conclusions: 2% CHX application for 15 sec proved to alleviate the decrease of bond strength of dentin bonding systems. No significant difference was shown in ${\mu}TBS$ between total-etching system and self-etching system.

INFLUENCE OF APPICATION TIME OF SELF-ETCHING PRIMERS ON DENTINAL MICROTENSILE BOND STRENGTH (자가 산부식 프라이머의 적용시간이 상아질의 미세인장 결합강도에 미치는 영향)

  • Cho, Young-Gon;Lee, Young-Gon;Kim, Jong-Uk;Park, Byung-Cheul;Kim, Jong-Jin;Choi, Hee-Young;Jin, Cheul-Hee;Yoo, Sang-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.430-438
    • /
    • 2004
  • This study evaluated the influence of application time of self-etching primers on microtensile bond strength (${\mu}$TBS) to dentin using three self-etching primer adhesive systems. Dentin surfaces were exposed from forty-eight human molars. They were conditioned with three self-etching primers (Clearfil SE Bond [SE], Unifil Bond [UF], Tyrian SPE + One Step Plus [TY]) and different primining times (10s, 20s, 30s and 40s). Composite resins were bonded to dentin surfaces and specimens were made. ${\mu}TBS$ was tested and statistically compared using by one-way ANOVA and Tukey's Test. The results of this study presented that priming time for 10s in SE and UF groups and for 30s and 40s in TY group was highly decreased ${\mu}TBS$ to dentin.

Effect of dentin pretreatment and curing mode on the microtensile bond strength of self-adhesive resin cements

  • Youm, Seung-Hyun;Jung, Kyoung-Hwa;Son, Sung-Ae;Kwon, Yong-Hoon;Park, Jeong-Kil
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.317-322
    • /
    • 2015
  • PURPOSE. The aim was to evaluate the effect of curing mode and different dentin surface pretreatment on microtensile bond strength (${\mu}TBS$) of self-adhesive resin cements. MATERIALS AND METHODS. Thirty-six extracted human permanent molars were sectioned horizontally exposing flat dentin surface. The teeth were divided into 12 groups (3 teeth/group) according to the dentin surface pretreatment methods (control, 18% EDTA, 10% Polyacrylic acid) and curing mode (self-curing vs. light-curing) of cement. After pretreatment, composite resin blocks were cemented with the following: (a) G-CEM LinkAce; (b) RelyX U200, followed by either self-curing or light-curing. After storage, the teeth were sectioned and ${\mu}TBS$ test was performed using a microtensile testing machine. The data was statistically analyzed using one-way ANOVA, Student T-test and Scheffe's post-hoc test at P<.05 level. RESULTS. For G-CEM LinkAce cement groups, polyacrylic acid pretreatment showed the highest ${\mu}TBS$ in the self-cured group. In the light-cured group, no significant improvements were observed according to the dentin surface pretreatment. There were no significant differences between curing modes. Both dentin surface pretreatment methods helped to increase the ${\mu}TBS$ of RelyX U200 resin cement significantly and degree of pretreatment effect was similar. No significant differences were found regarding curing modes except control groups. In the comparisons of two self-adhesive resin cements, all groups within the same pretreatment and curing mode were significantly different excluding self-cured control groups. CONCLUSION. Selecting RelyX U200 used in this study and application of dentin surface pretreatment with EDTA and polyacrylic acid might be recommended to enhance the bond strength of cement to dentin.

Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements

  • Sadighpour, Leyla;Geramipanah, Farideh;Ghasri, Zahra;Neshatian, Mehrnoosh
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.40.1-40.10
    • /
    • 2018
  • Objectives: This study evaluated the microtensile bond strength (${\mu}TBS$) of polymer-ceramic and indirect composite resin with 3 classes of resin cements. Materials and Methods: Two computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated polymer-ceramics (Enamic [ENA; Vita] and Lava Ultimate [LAV; 3M ESPE]) and a laboratory indirect composite resin (Gradia [GRA; GC Corp.]) were equally divided into 6 groups (n = 18) with 3 classes of resin cements: Variolink N (VAR; Vivadent), RelyX U200 (RXU; 3M ESPE), and Panavia F2 (PAN; Kuraray). The ${\mu}TBS$ values were compared between groups by 2-way analysis of variance and the post hoc Tamhane test (${\alpha}=0.05$). Results: Restorative materials and resin cements significantly influenced ${\mu}TBS$ (p < 0.05). In the GRA group, the highest ${\mu}TBS$ was found with RXU ($27.40{\pm}5.39N$) and the lowest with VAR ($13.54{\pm}6.04N$) (p < 0.05). Similar trends were observed in the ENA group. In the LAV group, the highest ${\mu}TBS$ was observed with VAR ($27.45{\pm}5.84N$) and the lowest with PAN ($10.67{\pm}4.37N$) (p < 0.05). PAN had comparable results to those of ENA and GRA, whereas the ${\mu}TBS$ values were significantly lower with LAV (p = 0.001). The highest bond strength of RXU was found with GRA ($27.40{\pm}5.39N$, p = 0.001). PAN showed the lowest ${\mu}TBS$ with LAV ($10.67{\pm}4.37N$; p < 0.001). Conclusions: When applied according to the manufacturers' recommendations, the ${\mu}TBS$ of polymer-ceramic CAD/CAM materials and indirect composites is influenced by the luting cements.

Evaluation of Microtensile Bond Strength of Sealant Depending on the Duration of Etching and the Use of Bonding Agent (치면열구전색제의 산부식 시간과 접착제 유무에 따른 미세인장결합강도 평가)

  • Shim, Seoyoun;Song, Hojun;Yang, Sunmi;Kim, Jaehwan;Kim, Seonmi;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.299-306
    • /
    • 2018
  • The aim of this study was to evaluate the effect of etching time and bonding agents on bond strength of sealant applied to the occlusal surface of primary molars. Forty non-carious exfoliated human primary molars were included in the study. The teeth were randomly divided into 4 groups for measurement. For group I, no acid etching treatment was used. For group II, III, and IV, acid etching gels were applied on the occlusal surface for 15, 30, and 60 seconds, respectively. Each group was divided into 2 subgroups; one group was treated with bonding agents on the enamel while the other was not. Microtensile bond strength was evaluated using a universal testing machine. There were no statistically significant differences in bond strength with varying duration of etching among groups. The results revealed that the use of bonding agents prior to application of fissure sealant increased the bond strength(p < 0.05). It could be concluded that etching time greater than 15 seconds does not significantly enhance the bond strength, but the use of bonding agents as an intermediate layer between the primary molar and fissure sealant would be beneficial in increasing the bond strength.