• Title/Summary/Keyword: Microprocessor-based

Search Result 493, Processing Time 0.026 seconds

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Power Analysis Attacks on the Stream Cipher Rabbit (스트림 암호 Rabbit에 대한 전력분석 공격)

  • Bae, Ki-Seok;Ahn, Man-Ki;Park, Jea-Hoon;Lee, Hoon-Jae;Moon, Sang-Jae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.3
    • /
    • pp.27-35
    • /
    • 2011
  • Design of Sensor nodes in Wireless Sensor Network(WSN) should be considered some properties as electricity consumption, transmission speed, range, etc., and also be needed the protection against various attacks (e.g., eavesdropping, hacking, leakage of customer's secret data, and denial of services). The stream cipher Rabbit, selected for the final eSTREAM portfolio organized by EU ECRYPT and selected as algorithm in part of ISO/IEC 18033-4 Stream Ciphers on ISO Security Standardization recently, is a high speed stream cipher suitable for WSN. Since the stream cipher Rabbit was evaluated the complexity of side-channel analysis attack as 'Medium' in a theoretical approach, thus the method of power analysis attack to the stream cipher Rabbit and the verification of our method by practical experiments were described in this paper. We implemented the stream cipher Rabbit without countermeasures of power analysis attack on IEEE 802.15.4/ZigBee board with 8-bit RISC AVR microprocessor ATmega128L chip, and performed the experiments of power analysis based on difference of means and template using a Hamming weight model.

FPGA integrated IEEE 802.15.4 ZigBee wireless sensor nodes performance for industrial plant monitoring and automation

  • Ompal, Ompal;Mishra, Vishnu Mohan;Kumar, Adesh
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2444-2452
    • /
    • 2022
  • The field-programmable gate array (FPGA) is gaining popularity in industrial automation such as nuclear power plant instrumentation and control (I&C) systems due to the benefits of having non-existence of operating system, minimum software errors, and minimum common reason failures. Separate functions can be processed individually and in parallel on the same integrated circuit using FPGAs in comparison to the conventional microprocessor-based systems used in any plant operations. The use of FPGAs offers the potential to minimize complexity and the accompanying difficulty of securing regulatory approval, as well as provide superior protection against obsolescence. Wireless sensor networks (WSNs) are a new technology for acquiring and processing plant data wirelessly in which sensor nodes are configured for real-time signal processing, data acquisition, and monitoring. ZigBee (IEEE 802.15.4) is an open worldwide standard for minimum power, low-cost machine-to-machine (M2M), and internet of things (IoT) enabled wireless network communication. It is always a challenge to follow the specific topology when different Zigbee nodes are placed in a large network such as a plant. The research article focuses on the hardware chip design of different topological structures supported by ZigBee that can be used for monitoring and controlling the different operations of the plant and evaluates the performance in Vitex-5 FPGA hardware. The research work presents a strategy for configuring FPGA with ZigBee sensor nodes when communicating in a large area such as an industrial plant for real-time monitoring.

A Design of Software Receiver for GNSS Signal Processing

  • Choi, Seung-Hyun;Kim, Jae-Hyun;Shin, Cheon-Sig;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.48-52
    • /
    • 2007
  • Recently, the research of GPS receiver which uses the Software-Defined Radio(SDR) technique is being actively proceeded instead of traditional hardware-based receiver. The software-based GPS receiver indicates that the signal acquisition and tracking treated by the hardware-based platform are processed as the software technique through a microprocessor. In this paper, GPS software receiver is designed by using SDR technique and then the signal acquisition, tracking, and the navigation message decoding parts are verified through the PC-based simulation. Moreover, the efficient algorithms are developed about the signal acquisition and tracking parts in order to obtain the accurate pseudorange. Finally, the pseudorange is calculated through the relative channel delay received through the different satellite of L1 frequency band. GPS software receiver proposed in this paper will be included in the element of GPS/Galileo complex system of development target and will provide not only the method that verifies the performance for Galileo Sensor Station standard but also usability by providing various debugging environments.

  • PDF

A Study On RTLS(Real Time Location System) Based on RSS(Received Signal Strength) and RSS Characteristics Analysis with the External Factors (외적요인에 따른 RSS 특성 분석과 이를 이용한 실시간 위치 추적 시스템 구현에 관한 연구)

  • Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.76-85
    • /
    • 2011
  • In this paper, we analysed RSS characteristics by external factors and presented an efficient algorithm for real-time location tracking and its hardware system. The proposed algorithm enhanced the ranging accuracy using Kalman Filter based on the RSS DB. The location tracking system that consists of the tag, AP(Access Point), a data collector(Data Receiver) with IEEE 802.15.4(ZigBee) network environment, and location tracking application that reveal locations of each tag is implemented for the test environment. The location tracking system presented in this paper is implemented with MSP430 microprocessor manufactured by TI(Texas Instrument), CC2420 RF chipset and the location tracking application. With the results of the experiment, the proposed algorithm and the system can achieve the efficiency and the accuracy of location tracking with the average error of 19.12cm, and its standard deviation of 5.31cm in outdoor circumstance. Also, the experimental result shows that exact tracking of position in indoor circumstance cannot achieve because of vulnerable RSS with external circumstance.

A Study on the Utilization and Control Method of Hybrid Switching Tap Based Automatic Voltage Regulator on Smart Grid (스마트그리드의 탭 전환 자동 전압 조정기의 다중 스위칭 제어 방법 및 활용 방안에 관한 연구)

  • Park, Gwang-Yun;Kim, Jung-Ryul;Kim, Byung-Gi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.31-39
    • /
    • 2012
  • In this paper, we propose a microprocessor-based automatic voltage regulator(AVR) to reduce consumers' electric energy consumption and to help controlling peak demanding power. Hybrid Switching Automatic Voltage Regulator (HS-AVR) consist of a toroidal core, several tap control switches, display and command control parts. The coil forms an autotransformer which has a serial main winding and four parallel auxiliary windings. It controls the output voltage by changing the combination of the coils and the switches. Relays are adopted as the link switches of the coils to minimize the loss. To make connecting and disconnecting time accurate, relays of the circuit have parallel TRIACs. A software phase locked loop(PLL) has been used to synchronize the timings of the switches to the voltage waveform. The software PLL informs the input voltage zero-crossing and positive/negative peak timing. The traditional voltage transformers and AVRs have a disadvantage of having a large mandatory capacity to accommodate maximum inrush current to avoid the switch contact damage. But we propose a suitable AVR for every purpose in smart grid with reduced size and increased efficiency.

A Study on the Implementation of PC Interface for Packet Terminal of ISDN (ISDN 패킷 단말기용 PC 접속기 구현에 관한 연구)

  • 조병록;박병철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.12
    • /
    • pp.1336-1347
    • /
    • 1991
  • In this paper, The PC interface for packet terminal of ISDN is designed and implemented in order to build packet communication networks which share computer resources and exchange informations between computer in the ISDN environment. The PC interface for packet terminal of ISDN constitutes S interface handler part which controls functions of ISDN layer1 and layer 2, constitutes packet handler part which controls services of X.25 protocol in the packet level.Where, The function of ISDN layer1 provides rules of electrical and mechanical characteristics, services for ISDN layer 2. The function of ISDN layer 2 provides function of LAPD procedure, services for X.25 The X.25 specifies interface between DCE and DTE for terminals operrating in the packet mode. The S interface handler part is orfanized by Am 79C30 ICs manufactured by Advanecd Micro Devices. ISDN packet handler part is organiged by AmZ8038 for FIFO for the purpose of D channel. The common signal procedure for D channel is controlled by Intel's 8086 microprocessor. The S interface handler part is based on ISDN layer1,2 is controlled by mail box in order to communicate between layers. The ISDN packet handler part is based on module in the X.25 lebel. The communication between S interface handler part and ISDN packet handler part is organized by interface controller.

  • PDF

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF

Development of Digital Solder Station Based on PID Controller (PID 제어기를 이용한 전기인두기의 온도 제어 시스템 개발)

  • Oh, Kab-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.866-872
    • /
    • 2010
  • In this paper, we developed a digital soldering station based on PID controller, which supply stable power by controlling the current of heater of soldering iron. The proposed system designed PID controller to converge quickly to the set up temperature by user, and regain the lost of heat by external factors quickly. PID controller, designed by Ziegler-Nichols' tuning method, decides triac's trigger timing using setting temperature and present temperature to control the phase of AC 24V power that supply to the heater. Also, we give the function that shows present temperature and setting temperature of iron, and working time by graphic LCD. And during the rest time, we decided the power saving and extension of iron tip by dropping to the optimal temperature. Two experiments had implemented in $25^{\circ}C$ laboratory to confirm the performance of proposed method. The first experiment took 12sec, 13sec, 16sec, 18sec, reaching to $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ respectively which result showed shorten of rising time than previous method. In the loading experiment of $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ steady state showed temperature drop of $3.8^{\circ}C$, $4.1^{\circ}C$, $4.5^{\circ}C$ which result showed the low temperature deviation than previous method.

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF