• Title/Summary/Keyword: Microprocessor-based

Search Result 493, Processing Time 0.028 seconds

A Study on Design and Implementation of an Analog Addressable Detector and a Fire Alarm System (아날로그 주소형 감지기와 자동화재탐지 시스템의 설계 및 구현사례에 대한 고찰)

  • Kim, Chong-Tai;Hong, Se-Kwun;Yoo, Young-Shin;Jung, Hae-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.1-11
    • /
    • 2010
  • This paper describes a design and implementation of an analog detector and a fire alarm system with recent technology on information and communication. A hierarchical architecture design from the detector to the main system enables to accommodate medium to large size buildings located nearby or far-away. And a software design from communication protocol to application program handles large amount of events efficiently to show information on a large LCD. A PC-based alarm system provides higher speed and larger capacity in a large LCD screen compared with foreign microprocessor-based small screen systems. Thus, very large buildings with several thousands of analog detectors can be easily covered in a single system. When an alarm occurs, a staff alarm scenario specially attempted only in the system is considered to play a major role to distinguish a real fire from unwanted alarms.

A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor (마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구)

  • Lee, Kang-Hwi;Lee, Sung-Su;Lee, Jeong-Whan;Song, Ha-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.

A HANGEUL Character Input Output Terminal Controlled by Microprocessor (마이크로.프로세서를 이용한 한글문자 입출력시스템)

  • ;富永英義
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.2
    • /
    • pp.8-14
    • /
    • 1978
  • This paper discusses topics, which can be considered to generate a HANGEUL character pattern with general micro-processor.: A character must be composed by combining the input elements at their proper sizes and positions based on algorithm proposed here.

  • PDF

PATIENT WORN, INTELLIGENT ARRHYTHMIA SYSTEMS (환자경고 및 지능부정맥 시스템)

  • Lee, Myoung-Ho;Tompkins, Willis J.
    • Proceedings of the KIEE Conference
    • /
    • 1986.07a
    • /
    • pp.192-197
    • /
    • 1986
  • The device that we are developing is a microprocessor-based, portable arrhythmia monitor that ultimately will need processing algorithm similar to those found now in monitoring systems in the cardiac care unit of today's hospital. Our initial goal is to replace the functions of the Holter tape recorder, the current device of choice for determining if an ambulatory patient has potential heart disease.

  • PDF

A Study on the Optimization of Temprature Controller Using Microprocessors (마이크로프로세서를 이용한 온도제어장치의 최적화에 관한 연구)

  • 김명규;장익수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.4
    • /
    • pp.18-22
    • /
    • 1980
  • Lately, the need for the use of calorimeter has been increased id Korea. Therefore, several met hods for the optimization of the microcomputer-based control system that can be used as a temperatare controller as well as a calorimeter are described in this paper. The instrument designed in this paper has been proved to be more powerful and costeffect ice than any other instrument not using microprocessor.

  • PDF

VOLTAGE CONTROLLED PULSE WIDTH MODULATOR

  • Rahman, Md. Fayzur;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2200-2203
    • /
    • 1997
  • This paper presents a model for p voltage controlled pulse width modulator (VCPWM), which can be used in any phase controlled converter having either manual or microprocessor based control. The circuit uses only one 555 timer, an OpAmp, some resistors, and capacitors. Although a large varieties of such circuits are available in the literature, this model is very simple with low cost and high performance.

  • PDF

Inverter Resistance Spot Welders with Servo Gun System

  • Kim Gyu-Sik;Sohn Woo-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.117-120
    • /
    • 2001
  • Resistance spot welding is widely employed in a manufacturing process. In recent years, the requirement for more sophisticated quality control procedures has been in the mass production industries. The requirements for high productivity and good welding qualities have lead to the development of more widely available microprocessor or computer based control. In this study, the inverter-type power source and welding servo gun are developed.

  • PDF

A development of simulator for satellite power system (인공위성용 전력시스템 시뮬레이텨 개발)

  • 김영태;김희준
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.193-201
    • /
    • 1996
  • The space power system for communication satellite which employs the direct energy transfer (DET) method consists of solar array, battry, shunt regulator, charger/discharger and power control unit (PCU). In this paper, the development of the DET power system charger/discharger unit and a microprocessor based PCU is developed for simplicity and flexiblity in the modificatin of control algorithm. A 28V bus voltage, 400W power rting power simulator is built and tested to verify the operation of the simulator at each mode and the stability of mode transition is analyzed.

  • PDF

Development of Inverter Resistance Spot Welding Controller (서보건을 이용한 인버터 저항 스폿용접기의 제어기 개발)

  • 김규식
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.568-571
    • /
    • 2000
  • Resistance spot welding is widely employed in a manufacturing process. In recent years the requirement for more sophisticated quality control procedures has been in the mass production industries. The requirements for high productivity and good welding qualities have lead to the development of more widely available microprocessor or computer based control, In this paper the inverter-type power source and welding servo gun are developed.

  • PDF

Development of the Patient Monitor Using Microprocessor (마이크로 프로세서에 의한 환자감시장치의 개발)

  • 김남현;유선국
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.309-316
    • /
    • 1989
  • In this paper, the patient monitor consisting of amplifier, scan converter, A/D converter, CRT amplifier, and micro-controller part was developed. This patient monitor measures the patient's 4 states in the hospital such as electro-cardiography, respiration, blood pressure, and temperature. The control and processing methods based on micro-processor employ the flexibility, extensibility and economy over other conventional system. The followings are incorporated in this system. First, record the heart rate trends for 1 and 4 hours respectively. Second, measures the respiration by impedance pneumography. Third, measures the blood pressure with auto-zero balance. Fourth, linesrize the temperatures by bridge method.

  • PDF