• 제목/요약/키워드: Microcomputer

검색결과 416건 처리시간 0.021초

PC 및 LAN을 이용한 외래처방 전달 시스템 (Computerized Order Communication System for Out-patient's Clinic Using Personal Computer and Local Area Network)

  • 김남현;김원기
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권4호
    • /
    • pp.321-326
    • /
    • 1993
  • Recently, microcomputer technology has been developed rapidly and it provides not only graphic user interface that can be fraendly accessable but also large storage capacity to han- dle much hospital information. Almost all the order communication system for hospital has been developed under the concept of host and terminal environment since last 20 years. However, host-terminal system has not been successful in korea simply because most of physicians prescibe for rrlany patients a day(sometimes more than 150 patients a day). Also, under the host-terminal environment, programs are not friendly implemented for users. Since March 1991, we had developed order communication system for out-patients(named YONSEI-PC) using personal computer(PC) and local area network(LAN) . Since September 1992, we has applied succesfully in the Yonsei Cardiovascular Center, Sevrance Hospital, Yonsei University College of Medicine. This system consisted with Server and Clients which is communicated through LAN(Ethernet). The system also use the Host computer(IBM 9221 170) as a data bank and communicates to the Server with emulation card(3270 emulator, Interlink Inc., Korea) . After introducing this system, it enables patients to receive drugs witllin 20 minutes after prescription of 300-400 patients per day and it seemed to be effective system not to reduce waiting time for the patients but also to remove charge-troubling(due to His-entry of prescription) . This system also seems to be effective in terms of office automatism for hospital management. However users, usually physitions, required more friendly and easy system to operate and we thought that the most important one to successfully introduce order communication computer system in the hospital is user interface.

  • PDF

EFFECTS OF GAS EXHAUSTED FROM GASOLINE ENGINE ON PLANTS GROWN IN THE GREENHOUSE

  • Sugimoto, H.;Yamashita, J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.487-494
    • /
    • 1993
  • In order to establish a fully automatized pest control in the a greenhouse , the authors developed a prototype of microcomputer installed spraying vehicle which traveled along the furrows. Since a power sprayer mounted on the vehicle was driven by gasoline engine, plants grown in the greenhouse might be injured by the gas exhausted from the engine. Thus , effects of exhausted gas on photosynthetic rate and the shedding of flowers and buds of plants were examined. At first, effects of exhausted gas on photosynthetic rate of potted sweet pepper (Capsicum annuum L.) and eggplant(Solanum melongena L.) plants were examined. In a closed vinyl house the engine was operated for 5 minutes and plants were exposed to the gas for 2hours in the daytime on a fine day. Photosynthetic rate did not significantly decreased by the treatment in both species. Secondly, effects of ehtylene on the shedding of flowers and buds of sesame (Sesamum indicum L. ) were examined. In the closed and partiall opened vinyl house, the engine was operated for 5 minutes and potted sesame plants were exposed to the gas for 12 hours in the night. In partially opened vinyl house, ethylene concentration decreased to 0 ppm 3 hours after the engine was stopped and flower and bud did not shed. In contrast, when vinyl house was closed ethylene concentration was 0.75 pm even 12 hours after the engine was stopped and flowers and buds shed markedly and epinasty was observed in upper young leaves. As mentioned above , it was revealed that injury of plants in the greenhouse caused by the gas exhausted from a gasoline engine could be prevented by providing suitable ventilation.

  • PDF

무인 스피드 스프레이어의 개발(I) -원격제어 및 유도케이블 시스템- (Development of Unmanned Speed Sprayer(I) -Remote Control and Induction Cable System-)

  • 장익주;김태한;조명동
    • Journal of Biosystems Engineering
    • /
    • 제20권3호
    • /
    • pp.226-235
    • /
    • 1995
  • 과수원 방제 작업 시 인체에 해로운 농약으로부터 운전자를 보호하고 노동력 및 농약의 절감, 환경오염의 방지 등의 효과를 꾀하기 위하여 무선 전파 리모콘을 이용한 무인 스피드 스프레이어의 원격제어 시스템을 개발함과 동시에 유도케이블식 주행유도 장치에 의한 자율주행 무인스피드 스프레이어를 개발하였다. 무인 스피드 스프레이어는 원격조종 시스템, 유도케이블 시스템, 장해물 검출장치, 제어 액튜에이터 등으로 구성되어 있고 원격조종 및 자율주행이 가능한 시스템이다. 무인화 한 스피드 스프레이어의 특징은 다음과 같다. 1) 무선 전파 리모콘과 유도 케이블에 의한 주행 유도장치를 개발하여 스피드 스프레이어에 장착한 결과 리모콘 조작방식과 주행 유도방식 모두 가능하였다. 2) 원격 조종은 주행 (전진, 후진), 조향, 3방향의 노즐 및 팬, 분무기, 주행정지 등 16종류의 조작이 가능하다. 3) 농업용 리모콘으로는 FSK방식보다 전송에러가 적은 DTMF방식이 우수하였으며, 농업용 특정 소전력 무선국이 필요하다고 생각된다. 4) 5개의 저임피던스 검출코일과 윈도우 컴퍼레이터 회로로 구성된 디지털식 케이블 유도 시스템은 2개의 검출코일에 유기 된 상대적 전압치로서 궤도를 수정하는 아날로그 검출방식보다 주행 성능이 우수하였다.

  • PDF

64채널 심장전기도 시스템 구현에 관한 연구 (A study on the development of 64 channels computerized cardiac mapping system)

  • 장병철;김남현;정성헌;라상원;조범구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.88-91
    • /
    • 1994
  • It is well known that multipoint and computerized intraoperative mapping systems improve the results of surgery for Wolff-Parkinson-White syndrome and show tremendous potential for opening an entirely new era of surgical intervention for the more common and lethal types of supraventricular tachyarrhythmias such as atrial flutter and atrial fibrillation. In addition, the ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 64 channel computerized data analysis system using microcomputer (Macintosh IIx) for basic research of electrophysiology and electrical propagation. The bipolar electrogram information is acquired from 64 cardiac sites simultaneously at a sampling rate of 1ksamples/sec with continuous and total data storage of up to 30 seconds. When the reference electrogram is selected and reference point is picked up, delay time from the reference point in displayed on two dimensional diagram of the heart. System design permits easy expansion to almost 256 simultaneous sites, This system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the results of diagnosis and surgical treatment for cardiac arrhythmia.

  • PDF

원격제어(遠隔制御) 스피드 스프레이어의 개발(開發)(1) -시작기(詩作機)의 제작(製作)- (Development of Remote control Speed Sprayer(l) -Trial-made Model-)

  • 장익주;이기명
    • Current Research on Agriculture and Life Sciences
    • /
    • 제9권
    • /
    • pp.11-20
    • /
    • 1991
  • 본(本) 연구(硏究)는 인체(人體)에 해(害)로운 농약(農藥)으로 부터 운전자(運轉者)를 보호(保護)하기 위하여 무인(無人) 스피드 스프레이어를 개발(開發)할 목적(目的)으로 수행(遂行)하였으며 무선(無線) 전파(電波) 리모콘에 의한 원격제어(遠隔制御) 시스템을 개발(開發)하기 위하여 수행(遂行)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. 234채널, 16명령을 발신(發信)할 수 있는 VHF 대 전파(電波) 리모콘을 제작(製作)하여, 스피드 스프레이어의 원격제어(遠隔制御)에 편용가능(便用可能)하였다. 2. 시판(市販)되고 있는 무선전화기(無線電話機)의 방식(方式)인 DTMF방식(方式)을 채용(採用)한 무선 리모콘을 사용(使用)할 경우 시판 무선전화기(無線電話機) 사용(使用)이 가능(可能)하여 송수신(送受信)기의 별도(別途) 제작(製作)이 필요 없는 잇점이 있었다. 3. 무선(無線) 전파(電波) 리모콘과 원칩 마이크로 컴퓨터를 이용(利用)하여 염가(廉價)이고 컴팩터한 원격조종(遠隔操縱) 조향장치(操向裝置) 및 원격조종(遠隔操縱) 변속장치(變速裝置), 원격조종(遠隔操縱) 약액(藥液) 살포장치(撒布裝置) 등(等)의 원격제어(遠隔制御) 시스템 제작(製作)이 가능(可能)하였다.

  • PDF

MBL 활용 수업이 중학교 학생들의 과학탐구능력과 그래프 작성 및 해석능력에 미치는 효과 (The Effects of MBL-Used Instruction on Scientific Inquiry Skill and Graph Construction and Interpreting Abilities of Middle School Students)

  • 최성봉
    • 한국지구과학회지
    • /
    • 제29권6호
    • /
    • pp.487-494
    • /
    • 2008
  • 본 연구의 목적은 7학년 "해수의 성분과 운동" 단원에서 MBL 실험 수업이 학생들의 과학탐구능력과 그래프 작성 및 해석능력에 미치는 효과를 알아본 연구로 그 결과는 다음과 같다. 첫째, 6차시에 걸쳐 MBL 수업을 실시하고 사후 t-검정을 통해 학생들의 과학탐구능력에 미치는 영향에 대해 분석하였다. 그 결과 실험집단과 통제집단 간 과학탐구 능력 결과에서 유의미한 차이가 나타나 MBL 수업이 학생들의 과학탐구능력 향상에 더 효과적임을 알 수 있었다. 둘째, 사후 t-검정을 통해 학생들의 그래프 작성 및 해석능력에 미치는 영향에 대해 분석하였다. 그 결과 실험집단과 통제집단 간에 그래프 작성능력에서는 유의미한 차이를 보이지 않았으나, 그래프 해석능력에서는 두 집단 간 유의미한 차이를 나타내고 있어 MBL을 활용한 수업이 학생들의 그래프 해석능력의 향상에 더 효과적임을 알 수 있었다.

인삼의 자동건조시스템 개발에 관한 연구 (A study on the Development of Automatic Drying System of Ginseng)

  • 강현아;장규섭;장동일
    • 한국식품과학회지
    • /
    • 제25권6호
    • /
    • pp.764-768
    • /
    • 1993
  • 자동으로 온도, 습도 및 중량을 감지하고, 히터, 송풍기, 가습기 및 제습기의 작동여부를 제어할 수 있는 자동 건조 시스템을 개발하여, 인삼을 시료로하여 열풍건조시의 건조온도와 건조기 내의 상대습도에 따른 건조특성을 구명하고, 각 건조조건에서의 이화학적 특성을 조사하였다. 인삼의 건조속도는 건조온도가 높고 건조기내의 상대 습도가 낮을수록 빨랐으며, 건조된 인삼의 hardness는 건조온도가 높을수록 높고, 건조실내의 상대습도는 25%에서 높았다. 건조온도가 높을수록 Hunter L value가 감소하고 a와 b value가 증가하는 경향을 보였으며, 갈변도가 높았다. 인삼의 건조과정중에 일어나는 수축은 건조온도가 높고 건조기내의 상대습도가 낮을수록 컸으며, 직경의 수축률이 길이의 수축률에 비해 컸다. 인삼의 조사포닌 함량은 건조온도와 상대습도에 영향을 받지 않았다.

  • PDF

식품의 가열살균공정 자동화 시스템의 개발 (A Control System for Automization of Food Sterilizing Process)

  • 안희우;조현덕;한봉호;김상봉
    • 한국수산과학회지
    • /
    • 제25권6호
    • /
    • pp.511-519
    • /
    • 1992
  • 식품의 가열살균공정에 있어서 자동화는 에너지 소비의 성력화와 품질과의 관계 최적화를 위한 필수조건 중의 하나이다. 이를 위하여 마이크로컴퓨터를 이음한 자동화 시스템을 개발하였다. 시스템의 성능 및 정확도는 고형식품으로 사용한 명태 고기풀의 가열살균과정에서의 열침투곡선과 열확산도의 정확도로써 검토하였다. 자동화 시스템을 이용하여 측정한 명태 고기풀의 열침투곡선은 전형적인 고형식품의 열침투곡선을 나타내었다. 열침투곡선으로 부터 계산된 열확산도의 경우, 일정 살균온도에서는 다른 조건의 변화에 관계없이 일정한 값을 나타내었다. 가열살균온도를 변화시켜 구한 열확산도를 문헌상에 보고된 열확산도 추정식으로 구한 값과 비교하였을 때, 큰 차이를 보이지 않았으며 그 차이는 $\pm10.0\%$이내였다.

  • PDF

$F_o$-값 측정 시스템의 개발 (Development of $F_o-value$ Measuring System)

  • 조현덕;한봉호;김상봉;옥영건
    • 한국수산과학회지
    • /
    • 제25권6호
    • /
    • pp.520-528
    • /
    • 1992
  • 식품의 가열살균공정의 최적화는 에너지 소비의 성력화를 위한 공정 자동화와 제품의 미생물학적 안전성 및 영양적, 기호적 품질을 감안하여 이루어져야 한다. 본 연구에서는 이미 개발한 마이크로컴퓨터를 이용한 자동화 시스템을 개선하여 미생물학적 안전성 확보를 위한 가열살균기준 설정에 필수적인 $F_o-값 측정 시스템을 개발하였다. $F_o-값은 가열살균 중인 명태 고기풀의 냉점에서의 온도변화에 따라 순간치사율(lethal rate)을 구하고 전체 공정에서의 치사율의 합(integrated lethality)을 $F_o-값으로 나타내었다. 또한 정확도는 냉점에서의 열침투곡선으로부터 계산된 열확산도의 정확도로써 검토하였다. $F_o-값은 다양한 온도에서의 미세한 조건의 변화에도 불구하고 정확한 측정이 가능하였다. 또한 다양한 조건에서 동시에 계산된 명태 고기풀의 열확산도는 문헌상에 보고된 추정식으로 구한 열확산도와 큰 차이를 보이지 않았으며, 그 차이는 $\pm12\%$이내였다.

  • PDF

훈제 굴 통조림의 가열살균기준 설정에 관한 연구 (Establishment of $F_o-value$ Criterion for Canned Smoked-Oyster In Cottonseed Oil)

  • HAN Bong-Ho;LEE Chang-Kook;IM Chi-Won;YU Hong-Sik
    • 한국수산과학회지
    • /
    • 제28권3호
    • /
    • pp.347-353
    • /
    • 1995
  • 훈제 굴 기름담금 통조림은 우리나라의 대표적인 수출용 수산물 통조림이지만, 가열살균공정의 기준이 정립되어 있지 않아서 생산공정에서 과잉열처리와 그에 따른 에너지의 낭비 및 품질저하를 피하지 못하고 있다. 따라서 본 연구에서는 가열살균공정에서의 에너지 소비와 제품의 미생물학적 안전성을 최적화하고자 하였다. 원료 생굴에서 검출된 대부분의 미생물은 증식속도가 빠르고 부패력이 강한 것이었다. 정상적인 전처리 후에 $110^{\circ}C$에서 Fo-값 5.92min으로 살균한 훈제 굴 기름담금 통조림에서는 장기 저장중에도 미생물이 전혀 검출되지 않았다. 따라서 훈제 굴 기름담금 통조림의 Fo-값으로는 6.0min 정도가 적당한 것으로 판단되었다.

  • PDF