• Title/Summary/Keyword: Microcolumn

Search Result 45, Processing Time 0.024 seconds

Double-deflector effects on a low voltage microcolumn (저전압 초소형 전자 칼럼에서 이중 편향기의 효과)

  • Jang, Won-Kweon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2628-2633
    • /
    • 2009
  • In a double deflector employed microcolumn, the variation of FOV and scan field width was investigated in mode of conversely biased double deflector to eliminate barrel distortion caused by aberration. The relationship between biased voltage of each deflector and electron emission tip voltage was studied for the maximum FOV and scan field width. The limitation and the linearity of zooming current image are also estimated as a function of electron emission tip voltage.

Construction of a Gradient ${\mu}LC/MS$ system and Its Application

  • Cheong, Won-Jo
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.103-106
    • /
    • 2002
  • A gradient LC/MS system was constructed and applied for separation of biological samples. For example, a rapid and simple analytical method without pretreatment based on gradient ${\mu}LC/MS$ with a disposable microcolumn has been developed to determine B group vitamins in urine. Urine samples were directly injected to the disposable home-made microcolumn. The microcolumn can be emptied after being used for a series of urine samples, and repacked with fresh stationary phase. An overdose of vitamin pills were swallowed by healthy volunteers and the urine samples were taken 1,2,3,5, and 8 hours after swallowing. Vitamins immediately showed up in urine, hit the maximum, and disappeared swiftly. This technique is expected to have some application for clinical purposes.

  • PDF

Study on the Structural Design of an Ultra-miniaturized Microcolumn with a Built-in Electrostatic Octupole Stigmator (정전형 8중극 비점수차 보정기가 내장된 극초소형 마이크로컬럼의 구조 설계 연구)

  • Tae Sik Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.52-61
    • /
    • 2023
  • We designed a novel ultra-miniaturized microcolumn structure having an stigmator to significantly improve throughput per unit time, which is the biggest disadvantage of microcolumns. We adopted the structure of the stigmator in the form of an electrostatic octupole electrode, and used an electrostatic quadrupole deflector with a relatively simple structure considering the increase in wiring due to the introduction of the stigmator. We have dramatically reduced the effect of astigmatism that occurs when the electron beam probe is scanned to the periphery of the target by introducing the stigmator between the control electrode and the deflector. As our numerical analysis simulation results, the field of view obtained as a result of this study is about 46.3% improved compared to our previous study, and the electron beam probe size of less than 10 nm was achieved in the entire field of view.

  • PDF

Study on Determination of Seven Transition Metal Ions in Water and Food by Microcolumn High-Performance Liquid Chromatography

  • Hu, Qiufen;Yang, Guangyu;Li, Haitao;Tai, Xi;Yin, Jiayuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.694-698
    • /
    • 2004
  • A new method for the simultaneous determination of seven transition metal ions in water and food by microcolumn high-performance liquid chromatography has been developed. The lead, cadmium, mercury, nickel, cobalt, silver and tin ions were pre-column derivatized with tetra-(4-aminophenyl)-porphyrin ($T_4$-APP) to form the colored chelates which were then enriched by solid phase extraction with $C_{18}$ cartridge. The enrichment factor of 50 was achieved by eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The chelates were separated on a ZORBAX Stable Bound microcolumn ($2.0{\times}50\;mm,\;1.8\;{\mu}m$)with methanol-tetrahydrofuran (95 : 5, v/v, containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) as mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector from 350-600 nm. The seven chelates were separated completely within 2.0 min. The detection limits of lead, cadmium, mercury, nickel, cobalt, silver and tin are 4 ng/L, 3 ng/L, 6 ng/L, 5 ng/L, 5 ng/L, 6 ng/L, 4 ng/L respectively in the original samples. This method was applied to the determination of the seven transition metal in water and food samples with good results.

Magnetic Micro-Deflector for a Microcolumn System (초소형 전자칼럼을 위한 마이크로 자기장 디플렉터 연구)

  • Kim, Young-Chul;Kim, Dae-Wook;Ahn, Seung-Joon;Kim, Ho-Seob;Park, Seong-Soon;Park, Kyoung-Wan;Hwang, Nam-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.426-431
    • /
    • 2007
  • We have fabricated a magnetic micro-deflector for a microcolumn system and tested its performance by operating it in the low energy region. The micro-deflector is composed of Cu coils around cylindrical cores with $500{\mu}m$ diameter. The diameter of the Cu coil itself is $100{\mu}m$. Two pairs of deflectors designed for a 2-dimensional scan, that is X and Y deflection, are fixed on an insulating plate. The low power performance of a magnetic micro-deflector attached to a microcolumn system has been tested and the magnitude of deflection is measured to be ${\sim}100{\mu}m/A$, which offers the possibility for practical applications of the magnetic micro-deflector.

Indirect Determination of Nitrite by Flame Atomic Absorption Spectrometry Using a Lead(IV) Dioxide Oxidant Microcolumn

  • Noroozifar, Meissam;Khorasani Motlagh, Mozhgan;Taheri, Aboozar;Homayoonfard, Marjan
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.875-880
    • /
    • 2006
  • A new, simple and fast flow injection analysis (FIA) method has been developed for the indirect determination of nitrite. The proposed indirect automatic method is based on the oxidation of nitrite to nitrate using a lead(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the $PbO_2$ solid phase reagent to Pb(II), which is measured by flame atomic absorption spectrometry. The absorbance of Pb(II) are proportional to the concentration of nitrite in the samples. The calibration curve was linear up to 30 mg $L ^{-1}$, with a detection limit of 0.11 mg $L ^{-1}$ for a 400 mL injected sample volume and a sampling rate of about 80 $h ^{-1}$. The results exhibit no interference from the presence of large amounts of ions. The developed procedure was found to be suitable for the determination of nitrite in foodstuffs and wastewaters. A relative standard deviation better than 0.9% was obtained in a repeatability study. The reliability of the method was established by parallel determination against the standard method.

Multiple Electron Beam Lithography for High Throughput (생산성 향상을 위한 멀티빔 리소그라피)

  • Choi, Sang-Kook;Yi, Cheon-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.235-238
    • /
    • 2005
  • A Multiple electron beam lithography system with arrayed microcolumns has been developed for high throughput applications. The small size of the microcolumn opens the possibility for arrayed operation on a scale commensurate. The arrayed microcolumns based on of Single Column Module (SCM) concept has been fabricated and successfully demonstrated. Low energy microcolumn lithography has been operated in the energy range from 250 eV to 300 eV for the generation of nano patterns. Probe beam current at the sample was measured about >1 nA at a total beam current of $0.5\;{\mu}A$ and a working distance of $\~1\;mm$. The magnitude of probe beam current is strong enough for the low energy lithography. The thin layers of PMMA resist have been employed. The results of nano-patterning by low energy microcolumn lithography will be discussed.

Fabrication of Electrostatic Electron Lens for Electron Beam Microcolumn using the Laser Micromachining (레이저 미세가공 기술을 이용한 초소형 전자빔 장치용 정전장 전자렌즈의 제작)

  • Ahn, Seung-Jun;Kim, Dae-Wook;Kim, Ho-Seop;Kim, Yeong-Jeong;Lee, Yong-San
    • Korean Journal of Materials Research
    • /
    • v.11 no.9
    • /
    • pp.792-796
    • /
    • 2001
  • For electron beam lithography and SEM(scanning electron microscopy) applications, miniaturized electrostatic lenses called a microcolumn have been fabricated. In this paper, we report the fabrication technique for 20~30$\mu\textrm{m}$ apertures of electron lenses based on silicon and Mo membrane using an active Q-switched Nd:YAG laser. Experimental conditions of laser micromachining for silicon and Mo membrane are improved. The geometrical structures, such as the diameter and the preciseness of the micron-size aperture are dependent upon the total energy of the laser pulse train, laser pulse width, and the diameter of laser spot.

  • PDF

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.