• 제목/요약/키워드: Microchips

검색결과 25건 처리시간 0.022초

Optofluidic packaging and patterning technologies for light emitting devices

  • Chung, Su-Eun;Jang, Ji-Sung;Lee, Seung-Ah;Lee, Ho-Suk;Kwon, Sung-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1272-1273
    • /
    • 2009
  • We demonstrate conformal phosphor coating and patterning methods on light emitting diodes (LEDs) using image processing based optofluidic maskless lithography (IP-OFML) system in microfluidic channels. IP-OFML allows a real-time detection and dynamic mask generation for packaging of randomly dispersed microchips. Our system detects each chip by considering rotation of the chip through image processing regardless of their arrangement error. Therefore, it precisely packages the chip making conformal polymer layer.

  • PDF

디지털 제어기를 이용한 LLC 공진형 컨버터의 설계 및 구현 (Design and Implementation of the LLC resonant converter using digital controller)

  • 현병철;이재호;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.74-76
    • /
    • 2008
  • 본 논문에서는 LLC 하프 브릿지 공진형 컨버터의 디지털 제어기 설계 및 실제적인 구현에 대해 기술한다. 분석된 LLC 컨버터의 소신호 특성을 기반으로 discrete domain에서 디지털 제어기를 설계 하였다. 설계된 디지털 제어기는 SMPS용으로 특성화된 Microchips사의 마이크로컨트롤러(MCU)인 dsPIC33f를 이용하여 구현되었으며, 아날로그 제어기와의 성능 비교는 실험을 통하여 검증 한다.

  • PDF

네오디뮴 영구자석을 이용한 미세칩 제거장치의 개발 (Development of Microchip Removal Equipment Using Neodymium Permanent Magnets)

  • 최성윤;왕준형;왕덕현
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.122-128
    • /
    • 2021
  • Machining operations require removal of chips to keep the coolant clean and fresh throughout the operation time. In this study, microchip removal equipment was developed using AutoCAD and CATIA programs for 3D modeling and 2D draft. In addition, the flow analysis and electromagnetic field analysis of the equipment were performed using the COMSOL Multiphysics program. The flow design of the coolant oil tank was realized on the basis of fluid analysis results. Further, on the basis of magnetic density analysis, a conveyer was designed for effectively removing metal microchips in the tank by using arrays of neodymium permanent magnets.

전기 분무 이온화를 이용한 단백질 질량분석용 마이크로 유체 소자의 제작 및 실험 (Sheathless electrospray ionization with integrated metal emitter on microfluidic device)

  • 김민수;주황수;이국녕;김병기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2102-2104
    • /
    • 2004
  • In this study, sheathless electrospray from PDMS/glass microchips with conducting metal emitter tip is described. A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system has advantages of the CE separation and on-line electrospray detection of peptide solution. We have fabricated a new electrospray ionization(ESI) device composed of the metal emitter tip and CE separation channel monolithically in a glass microchip. The separation channel and metal emitter tip are fabricated using a glass wet etching and gold electro plating process, respectively. The fabricated micro electrospray chip was tested by spraying peptide sample for mass spectrometric analysis. Singlely-charged peak and doublely-charged peak of peptide were detected and further MS/MS fragmentation was performed in each peak. Direct comparisons with conventional glass or fused silica emitters showed very similar performance with respect to signal strength and stability.

  • PDF

극저온 $CO_2$ 세정공정의 세정인자 최적화 (Optimization of Cleaning Parameters in Cryogenic $CO_2$ Cleaning Process)

  • 이성훈;석종원;김필기;오승희;석종혁;오병준
    • 한국정밀공학회지
    • /
    • 제25권9호
    • /
    • pp.109-115
    • /
    • 2008
  • The cleaning process of contaminant particles adhering to the microchips, integrated circuits (ICs) or the like is essential in modern microelectronics industry. In the cleaning process particularly working with the application of inert gases, the removal of contaminant particles of submicron scale is very difficult because the particles are prone to reside inside the boundary layer of the working fluid, The use of cryogenic $CO_2$ cleaning method is increasing rapidly as an alternative to solve this problem. In contrast to the merits of high efficiency of this process in the removal of minute particles compared to the others, even fundamental parametric studies for the optimal process design in this cleaning process are hardly done up to date, In this study, we attempted to measure the cleaning efficiency with the variations of some principal parameters such as mass flow rate, injection distance and angle, and tried to draw out optimal cleaning conditions by measuring and evaluating an effective cleaning width called $d_{50}$.

NSCR_PPS 소자에서 채널차단 이온주입 변화에 따른 최적의 정전기보호소자 설계 (Optimal Design of ESD Protection Device with different Channel Blocking Ion Implantation in the NSCR_PPS Device)

  • 서용진;양준원
    • 한국위성정보통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.21-26
    • /
    • 2016
  • PPS 소자가 삽입된 N형 실리콘 제어 정류기(NSCR_PPS) 소자에서 채널차단영역의 이온주입 변화가 정전기 보호 성능에 미치는 영향을 연구하였다. 종래의 NSCR 표준소자는 on 저항, 스냅백 홀딩 전압 및 열적 브레이크다운 전압이 너무 낮아 마이크로칩의 정전기보호소자로 적용이 어려웠다. 그러나 본 연구에서 제안하는 채널 차단 영역의 이온주입 조건을 변화시켜 각각 변형설계된 소자에서는 채널 차단 이온주입이 정전기 보호성능의 향상에 영향을 주는 중요한 파라미터였으며, CPS_PDr+HNF 구조의 변형소자는 정전기보호소자의 설계창을 만족시키는 향상된 정전기보호성능을 나타내어 고전압 동작용 마이크로 칩의 정전기보호 소자로 적용 가능함을 확인하였다.

적외선 건조 및 열풍 건조에 대한 전도성 잉크의 건조 특성에 관한 연구 (A study on the drying characteristics of conductive ink by infrared drying system and the hot-air drying system)

  • 정길용;이재효;홍승찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.183-188
    • /
    • 2009
  • RFID method is a non-contact automatic identification technology, which attaches microchips and antennas to an object in a tag form, to send and process information sent to the network using wireless frequency. Drying and curing process is extremely important which minimizes the resistivity of RFID antennas. This research is about the drying characteristic of conductivity ink, and analyzes and compares the hot-air drying process and infrared drying process. Also, the research was done for the improvement in drying performance by using combined process of hot-air and infrared mechanism. The experiment result shows that the hot-air or infrared drying system used alone cannot meet the required performance in drying printing method using conductivity ink. The combined drying system of hot-air and infrared ray showed resistance low enough in short drying and curing time, and this mechanism makes drying and curing process for mass and continuous production possible on-line.

  • PDF

네오디뮴 영구자석을 이용한 컨베이어벨트 구동형 미세칩 포집장치의 성능 평가 (Performance Evaluation of Microchip Removal Device Rotating by Conveyor Belt with Neodymium Permanent Magnet)

  • 최성윤;왕준형;왕덕현
    • 한국기계가공학회지
    • /
    • 제20권1호
    • /
    • pp.103-109
    • /
    • 2021
  • Fine chips generated by machining have an impact on machine failure and quality of machined products, it is necessary to remove the chips, so the microchip collection and removal device by rotating conveyor belt with neodymium permanent magnets was developed. In this research, to solve the problem for reducing the existing microchips in the tank, a micro-chip removal device by rotating conveyor belt with neodymium permanent magnets developed. In the development of micro-chip removal device, 3D CATIA modeling was used, and the flow analysis and the electromagnetic force analysis were performed with COMSOL Multiphysics program. To evaluate the performance of the prototypes produced, design of experiments (DOE) is used to obtain the effect of neodymium conveyor movement speed on chip removal for the ANOVA analysis of recovered powders. An experiment was conducted to investigate the effect of the conveyor feed rate on the chip removal performance in detail. As a result of the experiment, it was confirmed that the slower the feeding speed of the fine chip removing device, the more efficient the chip removal.

온도 프로파일 가시화를 통한 프랙탈 구조 마이크로채널 히트싱크의 열수력학적 특성 최적화 (Direct Visualization of Temperature Profiles in Fractal Microchannel Heat Sink for Optimizing Thermohydrodynamic Characteristics)

  • 이한솔;곽노균
    • 한국가시화정보학회지
    • /
    • 제22권1호
    • /
    • pp.79-84
    • /
    • 2024
  • As microchips' degree of integration is getting higher, its cooling problem becomes important more than ever. One of the promising methods is using fractal microchannel heat sink by mimicking nature's Murray networks. However, most of the related works have been progressed only by numerical analysis. Perhaps such lack of direct experimental studies is due to the technical difficulty of the temperature and heat flux measurement in complex geometric channels. Here, we demonstrate the direct visualization of in situ temperature profile in a fractal microchannel heat sink. By using the temperature-sensitive fluorescent dye and a transparent Polydimethylsiloxane window, we can map temperature profiles in silicon-based fractal heat sinks with various fractal scale factors (a=1.5-3.5). Then, heat transfer rates and pressure drops under a fixed flow rate were estimated to optimize hydrodynamic and thermal characteristics. Through this experiment, we found out that the optimal factor is a=1.75, given that the differences in heat transfer among the devices are marginal when compared to the variances in pumping power. This work is expected to contribute to the development of high-performance, high-efficiency thermal management systems required in various industrial fields.

6족 보행로봇에 관한 기초연구 (A Basic Study of Hexapod Walking Robot)

  • 강동현;민영봉;반전훈구;매전간웅
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.339-347
    • /
    • 2007
  • A hexapod walking robot had been developed for gathering information in the field. The developed robot was $260{\times}260{\times}130$ ($W{\times}L{\times}H$, mm) in size and 14.7 N in weight. The legs had nineteen degrees of freedom. A leg has three rotational joints actuated by small servomotors. Two servomotors placed at ankle and knee played the roles of vertical joint for up and down motions of the leg and the other one placed at coxa played the role of horizontal joint for forward and backward motions. In addition, a servomotor placed at thorax between the front legs and the middle legs played the role of vertical joint for pumping the two front legs to climb stair or inclination. Walking motion of the robot was executed by tripod gait. The robot was controlled by manual remote-controller communicated by an infrared ray. Two controllers were equipped to control the walking of the robot. The sub-controller using PIC microcomputer (Microchips, PIC16F84A) received the 16 bit command signal from the manual remote controller, decoded it to 8bit and transmitted it to the main microcomputer (RENESAS, SH2/7045), which controlled the 19 servomotors using the PWM command signals. Walking speeds were controlled by adjusting the period of command cycle and the stride. Forward walking speed were within 100 cm/min to 300 cm/min. However, experimental walking speed had the error of 4-40 cm/min to compare with the theoretical one, because of slippage of the leg and the circular arc motion of servomotor of coxa.