• Title/Summary/Keyword: Microbubble

Search Result 106, Processing Time 0.029 seconds

A Study on the Solubilisation of Excess Sludge using Microbubble Ozone (잉여슬러지 가용화를 위한 마이크로버블 오존 이용에 관한 연구)

  • Lee, Shun-Hwa;Jung, Kye-Ju;Kwon, Jin-Ha;Lee, Se-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.325-332
    • /
    • 2010
  • This study was conducted with the experiment of solubilisation of excess sludge by microbubble ozone process. To improve ozone contact efficiency, microbubble ozones which its diameter were the avearge 30 ${\mu}m$, microbubble size less than 40 ${\mu}m$ occupied about over 90% of all. In treating sludge using microbubble ozones, in case microbubble ozones are injected at microbubble ozone dosage of 0.34 g $O_3/g$ SS or less regardless of sludge concentration, microbubble ozone consumption rate was found to be 100% with no emission of waste ozones. In treating sludges by each concentration, in case the initial SS concentration of sludge is set to 6,447 mg/L, 5,557 mg/L, 3,180 mg/L, 1,092 mg/L and 515 mg/L, the amount of removed SS tended to increase with increase in initial SS concentration for the same microbubble ozone dosage, and treatment of sludge with high initial SS concentration was effective in raising the oxidation efficiency of microbubble ozones. On the other hand, as a result of reviewing acid, alkali and microbubble ozone treatment as composite treatment of sludge, use of acid treatment for the pre-treatment of microbubble ozone was more effective than alkali treatment, and in case of treatment at microbubble ozone dosage 0.05g $O_3/g$ SS with the concentration of sulfuric acid infused in the sludge, the amount of removed SS, 153.9 g, was 1.9 times more than 81.2 g the amount of single treatment of microbubble ozone.

Multiphase CFD Analysis of Microbubble Generator using Swirl Flow (선회유동을 이용한 마이크로버블 발생기의 다상유동 전산유체역학 해석)

  • Yun, S.I.;Kim, H.S.;Kim, J.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Microbubble technology has been widely applied in various industrial fields. Recently, research on many types of microbubble application technology has been conducted experimentally, but there is a limit in deriving the optimal design and operating conditions. Therefore, if the computational fluid dynamics (CFD) analysis of multiphase flow is used to supplement these experimental studies, it is expected that the time and cost required for prototype production and evaluation tests will be minimized and optimal results will be derived. However, few studies have been conducted on multiphase flow CFD analysis to interpret fluid flow in microbubble generators using swirl flow. In this study, CFD simulation of multiphase flow was performed to analyze the air-water mixing process and fluid flow characteristics in a microbubble generator with a dual-chamber structure. Based on the simulation results, it was confirmed that a negative pressure was formed on the central axis of rotation due to the strong swirling flow. And it could be seen that the air inside the suction tube was introduced into the inner chamber of the microbubble generator. In addition, as the high-speed mixed fluid collided with external water sucked by the negative pressure near the outlet, a large amount of microbubbles was ejected due to the shear force between the two flows flowing in opposite directions.

Effects of ultrasonic and microbubble treatment on serum components and innate immunity in rainbow trout (Oncorhynchus mykiss) (초음파와 microbubble 처리가 무지개송어(Oncorhynchus mykiss)의 혈청성분 및 선천성 면역에 미치는 영향)

  • Kim, Jin-Young;Park, Jong-Bin;Park, Jeong Su;Kim, Woo-Seoung;Kim, Hak Soo;Kwon, Se Ryun
    • Journal of fish pathology
    • /
    • v.32 no.2
    • /
    • pp.91-96
    • /
    • 2019
  • Rainbow trout (Oncorhynchus mykiss) were treated with ultrasonic (40kHz) and microbubble. The organic serum components, glucose were decreased compared to control at microbubble single treatment (M) and ultrasonic treatment (UL), but glucose concentrations in fish serum of all experimental groups analyzed in this study were also within the normal range. The organic serum components, cholesterol and total protein were no significant change by ultrasonic and microbubble treatment. There were no significant changes in the lysozyme activity on ultrasonic and microbubble treatment. Serum bactericidal activity decreased on ultrasonic single treatment (UL) compared to the control (P<0.05), but the numbers of bacterial colonies were significantly lower than those in the negative (PBS). The results of this study indicate that ultrasonic and microbubble treatment did not have a critical effect on the serum composition and innate immunity of O. mykiss, and that it is a way to do not significant stress on the fish body as a countermeasure against sea lice.

Experimental Study of Friction Drag Reduction in Turbulent Flow with Microbubble Injection (미소기포 주입에 의한 마찰저항 감소에 대한 연구)

  • 김덕수;김형태;김우전
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.3
    • /
    • pp.1-8
    • /
    • 2003
  • For the experiment of the friction drag reduction by microbubble injection, a drag reduction water tunnel was specifically designed and made. Experimental apparatus and procedures were devised and developed for measuring the change of wall friction drag with microbubble injection. For fully-developed channel flows. the change of friction drag with important parameters of microbubble injection is investigated and the experimental data and results obtained are presented. The amount of friction drag reduction up to 25% is observed in the present study.

Parameter Optimization for Cost Reduction of Microbubble Generation by Electrolysis

  • Lucero, Arpon Jr;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.269-280
    • /
    • 2017
  • To lower the operational cost of microbubble generation by electrolysis, optimization of parameters limiting the process must be carried out for the process to be fully adopted in environmental and industrial settings. In this study, four test electrodes were used namely aluminum, iron, stainless steel, and Dimensionally Sable Anode (DSA). We identified the effects and optimized each operational parameter including NaCl concentration, current density, pH, and electrode distance to reduce the operational cost of microbubble generation. The experimental results showed that was directly related to the rate and cost of microbubble generation. Adding NaCl and narrowing the distance between electrodes caused no substantial changes to the generation rate but greatly decreased the power requirement of the process, thus reducing operational cost. Moreover, comparison among the four electrodes operating under optimum conditions revealed that aluminum was the most efficient electrode in terms of generation rate and operational cost. This study therefore presents significant data on performing costefficient microbubble generation, which can be used in various environmental and industrial applications.

Effect of Hydraulic Pressure on Bubble Dissolution Rate of Ejector Type Microbubble Generator (수압이 자흡식 마이크로버블 발생장치의 산소 용해율에 미치는 영향)

  • Kim, Hyun-Sik;Lim, Ji-Young;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.27-31
    • /
    • 2017
  • This study was performed to estimate bubble dissolution rate by change of hydraulic pressure according to increase of water depth. Experimental results showed that airflow rate was decreased by increase of hydraulic pressure. Because the force which acts on outlet of nozzle was increased by increase of hydraulic pressure. Mass-transfer coefficient decreased with decreasing airflow rate and increasing effective volume due to increase of hydraulic pressure as water depth increased. On the contrary, as the water depth increased, the bubble dissolution rate was increased because longer residence time of microbubble which was generated by ejector type microbubble generator. However it was thought that if water depth for capacity of ejector type microbubble generator is excessively increasing, bubble dissolution rate would be reduced due to low airflow rate and mass-transfer coefficient. Therefore, it is importance to consider the water depth when operating ejector type microbubble generator.

The design of an ejector type microbubble generator for aeration tanks

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.307-311
    • /
    • 2019
  • The ejector type microbubble generator, which is the method to supply air to water by using cavitation in the nozzle, does not require any air supplier so it is an effective and economical. Also, the distribution of the size of bubbles is diverse. Especially, the size of bubbles is smaller than the bubbles from a conventional air diffuser and bigger than the bubbles from a pressurized dissolution type microbubble generator so it could be applied to the aeration tank for wastewater treatment. However, the performance of the ejector type microbubble generator was affected by hydraulic pressure and MLSS(Mixed Liquor Suspended Solid) concentration so many factors should be considered to apply the generator to aeration tank. Therefore, this study was performed to verify effects of hydraulic pressure and MLSS concentration on oxygen transfer of the ejector type microbubble generator. In the tests, the quantity of sucked air in the nozzle, dissolved oxygen(DO) concentration, oxygen uptake rate(OUR), oxygen transfer coefficient were measured and calculated by using experimental results. In case of the MLSS, the experiments were performed in the condition of MLSS concentration of 0, 2,000, 4,000, 8,000 mg/L. The hydraulic pressure was considered up to $2.0mH_2O$. In the results of experiments, oxygen transfer coefficient was decreased with the increase of MLSS concentration and hydraulic pressure due to the increased viscosity and density of wastewater and decreased air flow rate. Also, by using statistical analysis, when the ejector type microbubble generator was used to supply air to wasterwater, the model equation of DO concentration was suggested to predict DO concentration in wastewater.

A study on Flotation of Crystalline Graphite by Microbubble Column (Microbubble Column에 의한 인상흑연(鱗狀黑鉛)의 부선(浮選)에 관한 연구(硏究))

  • Han, Oh-Hyung;Kang, Hyun-Ho
    • Resources Recycling
    • /
    • v.15 no.2 s.70
    • /
    • pp.37-44
    • /
    • 2006
  • The total amount of graphite reserves in Korea is about 260 thousand tons. Graphite larks international competitiveness it is mined in only few mines, but recently the demand of portable electronic has increased. Therefore a research for manufacturing domestic high purity graphite is necessary because all of high purity graphite used electrode of 2nd batter depends on expensive importation. A preprocessing level for producing high purity graphite, flotation was conducted using microbubble column machine. In this research $D_{50}=10.314{\mu}m$ sample was used which was produced after grinding 29.50% F.C. primary crushing sample($D_{50}=69.393{\mu}m$) for 20 minutes through attrition mill. As a result using this sample, product above 95% F.C. with recovery over 90% was obtained with only after first stage process through the microbubble column.

Development of Microbubble Flotation Technique for the Production of High Grade Coal (Microbubble Flotation에 의한 고품위(高品位) 석탄생산(石炭生産) 기술(技術) 개발(開發))

  • Han, Oh-Hyung;Park, Sin-Woong;Kim, Byoung-Gon
    • Resources Recycling
    • /
    • v.21 no.4
    • /
    • pp.44-52
    • /
    • 2012
  • The purpose of this study is to confirm the possibility of obtaining high grade coal from fixed carbon 20.68% coal. Also, the mineralogical, physical/chemical and liberation characteristics was found with the aim of decrease in ash amount, during the pre-processing of clean coal technology. In this study, batch flotation and microbubble column flotation that was appropriate for the processing of fine particles was used with the variation in kinds and quantity of frother, collector and depressant. Also grinding time, air flow rate and feeding rates were examined. As a result of batch flotation, using pulp density 20%, collector DMU-101+dodecyl amine(100 mL/ton), frother pine oil (200 mL/ton), depressant sodium silicate(1 kg/ton), obtained the result of ash rejection 81.55% and combustible recovery 70.23%. In result of microbubble column flotation, the result was ash rejection 83.85% and combustible recovery 70.42% under the condition of pulp density 5%, grinding time 5 min. collector DMU-101+DDA(100 mL/ton), frother AF65(5.4 L/ton), depressant SMP(3.5 kg/ton), wash water(360 mL/min.) and air flow rate(1,197 mL/min.).