• Title/Summary/Keyword: Microbial colony

Search Result 199, Processing Time 0.026 seconds

On the Microbial Contamination in Softdrink Manufacturing Process (청량음료의 미생물 오염에 대하여)

  • 김용배;이병국;유건희;조남선
    • Korean Journal of Microbiology
    • /
    • v.11 no.3
    • /
    • pp.129-133
    • /
    • 1973
  • The authors have investigated about the microbial contamination of goods which is a criterion of hygienic control. Conducting on investigation, a special attention has been paid on the rate of microbial contamination in the goods, especially in manufacturing process of the softdrink. The authors also made an experiment on total microbes which is the criterion of contamination in each step of the process and in raw materials together with materials to be used for subdividing. Results obtained were as follows : 1) The orgin of microbial contamination was found in bottle cap and in tap water, that is, there appeared 9 colony per ml in bottle cap and 31-74 colony per ml in tap water, respectively. 2) It was found that microbial contamination are 4 colony per ml in average through year. However, it appeared 1 colony per ml in winter and 8 colony per ml in summer. 3) Coliform groups are not detected in goods through a year. 4) There was no variation in number of total microbes after ion exchange resin passage in purification process of tap water. 5) The number of microbes in goods are decreased when the raw materials are treated in high temperature short time (HTST) sterilization.

  • PDF

간장 효모에 대하여

  • 이한창
    • Korean Journal of Microbiology
    • /
    • v.1 no.1
    • /
    • pp.48-50
    • /
    • 1963
  • The authors have investigated about the microbial contamination of goods which is a criterion of hygienic control. Conducting on investigation, a special attention has been paid on the rate of microbial contamination in the goods, especially in manufacturing process of the softdrink. The authors also made an experiment on total microbes which is the criterion of contamination in each step of the process and in raw materials together with materials to be used for subdividing. Results obtained were as follows : 1) The orgin of microbial contamination was found in bottle cap and in tap water, that is, there appeared 9 colony per ml in bottle cap and 31-74 colony per ml in tap water, respectively. 2) It was found that microbial contamination are 4 colony per ml in average through year. However, it appeared 1 colony per ml in winter and 8 colony per ml in summer. 3) Coliform groups are not detected in goods through a year. 4) There was no variation in number of total microbes after ion exchange resin passage in purification process of tap water. 5) The number of microbes in goods are decreased when the raw materials are treated in high temperature short time (HTST) sterilization.

  • PDF

Ozone-produced Oxidants Improve Water Quality Parameters and Microbial Colony Counts in the Semi-Recirculating Aquaculture System for Olive Flounder Paralichthys olivaceus (반순환여과양식시스템에서 오존 유래 잔류산화물이 넙치(Paralichthys olivaceus) 사육수의 수질과 미생물에 미치는 영향)

  • Jung, Sangmyung;Park, Woogeun;Park, Seongdeok;Park, Jeonghwan;Kim, Jae-Won;Kim, Pyong-kih
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.751-760
    • /
    • 2021
  • This study investigated the changes in water quality parameters and microbial colonies when ozone was applied to a semi-recirculating aquaculture system (semi-RAS) for the olive flounder Paralichthys olivaceus (500 g in average weight). Concentrations of ozone-produced oxidants (OPO) in rearing tanks were maintained at 0, 0.014, 0.025 mg/L as Cl2 for 26 days. Except total ammonia nitrogen, nitrite nitrogen, nitrate nitrogen, phosphate phosphorus, chemical oxygen demand, and total suspended solids decreased significantly with increasing OPO concentration in daily and weekly monitoring (P<0.05). Colony forming unit (CFU) counts of heterotrophic marine bacteria decreased in an OPO concentration-dependent manner. Overall reduction rates of microbial colonies in the treatments were 80% higher than those of the control (P<0.05). During the experiment, the OPO concentration-driven ozonation was reliably practiced without any adverse effects on the animals cultured in semi-RAS. Considering the biohazard, operating cost, and stability of ozonation, an OPO concentration of 0.014 mg/L would be sufficient to control water quality parameters and microbial colonies in a semi-RAS.

Microbial Extracellular Enzyme Detection on Agar Plates by Means of Fluorogenic Methylumbelliferyl-Substrates (Methylumbelliferyl 형광기질을 이용한 평판배지상의 미생물 체외 세포효소측정방법)

  • ;Hoppe, H.-G.
    • Korean Journal of Microbiology
    • /
    • v.28 no.3
    • /
    • pp.229-235
    • /
    • 1990
  • A rapid and sensitive method to detect the extracellular enzymatic activity of bacteria colonies grown on agar plates is described. Selective agar media supplemented with protein, starch, chitin, Tween-80, etc. are conventionally used to detect biochemical properties of bacteria. It has been experimentally demonstrated with bacteria pure cultures that fluorogenic Methylumbelliferyl (MUF)-substrates are excellent substrate analogues for normally occurring polymers. Based on MUF-substrate hydrolysis the new method provides reliable qualitative estimates of extracellular enzymatic properties of bacteria within minutes using pure cultures as well as agar p;ates prepared for colony counts. Extracellular enzyme activities of heterotrophic bacteria from freshwater ecosystems and marine sediment using this method are discussed.

  • PDF

Presence of Bacteria and Fungi in Inner Compartment of Personal Computers(PCs) (개인용 컴퓨터 내부에서 발견되는 세균과 곰팡이)

  • Kwon, Kil-Koang;Yoon, Seok-Min;Choi, Chang-Ho;Jeong, Bong-Geun;Lee, Ki-Won;Yi, Dong-Heui;Kim, Hyung-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.728-733
    • /
    • 2007
  • Presence and distribution of bacteria and fungi in inner compartment of PCs(Personal Computers) were investigated. Samples for the analysis were collected from inside of PCs which had been used in various facilities including public computer facilities, laboratories and computer training rooms of a university. Total number of PC examined in this study was 51 each. When the total CFU(colony forming unit) of the inner compartment of the PCs was measured, the bacterial count was found to be dependent on the operation time(total running time) of PCs. When the distribution of bacteria in the inner compartment of PCs was estimated, CPU(Central Processing Unit) cooling fan area showed the highest bacterial concentration(average 605 $CFU/cm^2$). In the case of the fungi, various opportunistic pathogens including Aspergillus sp. and Penicillium sp. were isolated and identified in the inner compartment of PCs. And the average of bacterial number in the dust collected from the PCs was 212 CFU/mg. These results indicated that handling of PC might have a risk of infection by the microorganism.

A Study on the Characteristics of Water Quality for Groundwater and Purified Water of Several Schools in Gyeongsangbukdo Province (경상북도지역 학교지하수 및 정수기통과수의 수질특성에 관한 연구)

  • Kim, Suk-Chan;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.575-580
    • /
    • 2011
  • This study characterized water quality of groundwater and purified water used for drinking water in 30 schools in Gyeongsangbukdo Province. The results of the study showed that 43% of groundwater and 45% of purified water were not suitable for drinking. Among them, microbial contaminations were the most serious problem. In raw groundwater, the exceeding rates of total colony counts was the highest in August (53.6%). Purified water samples showed higher rate of exceeding drinking water standard for total colony counts while showing lower rate of exceeding drinking water standard for total coliforms and fecal coliforms in March and August. Overall, proper managements for microbial contaminations are required for both groundwater and purified water. Furthermore, special attention should toward students not to drink water when groundwater or purified water exceeds the drinking water quality standard.

Method Development for Electrotransformation of Acidithiobacillus caldus

  • Chen, Linxu;Lin, Jianqun;Li, Bing;Lin, Jianqiang;Liu, Xiangmei
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.1
    • /
    • pp.39-44
    • /
    • 2010
  • Acidithiobacillus caldus is an acidophilic, chemolithotrophic bacterium that plays an important role in bioleaching. Gene transformation into A. caldus is difficult, and only the conjugation method was reported successful, which was a relatively sophisticated method. In this research, electrotransformation of A. caldus species was achieved for the first time using A. caldus Y-3 and plasmid pJRD215. Transformants were confirmed by colony PCR specific to the str gene on pJRD215, and the recovery of the plasmid from the presumptive transformants. Optimizations were made and the transformation efficiency was increased from 0.8 to $3.6{\times}10^4$ transformants/${\mu}g$ plasmid DNA. The developed electrotransformation method was convenient in introducing foreign genes into A. caldus.

Glycine Effect on Spheroplasting and Nodule Bacteroids of Rhizobium Jjaponicum (Rhizobium japonicum원형질체 형성과 근류 bacteroids에 미치는 glycine의 영향)

  • Kim, Sung-Hoon;Kim, Chang-Jin;Rhee, Yoon;Yoo, Ick-Dong;Mheen, Tae-Ick
    • Korean Journal of Microbiology
    • /
    • v.23 no.3
    • /
    • pp.197-202
    • /
    • 1985
  • Different spheroplasting methods using glycine were tried to fast and slow-growing R. japonicum. Although one of the fast growers, R-271 showed normal growth in the presence of 4mg/ml glycine, cell morphology and colony forming unit (CFU) were greatly different from the cells of late log phase grown in the medium without glycine. In parallel, R-271 became sensitive to lysozyme after 6hr incubation in medium containing glycine (3.5mg/ml). After 24hr cultivation in glycine $(100{\mu}g/ml)$ medium, one of the slow growers, R-214 was also susceptible to lysozyme action. Spgeroplasting frequency of both strains was over 96% by glycine and lysozyme. Spheroid cell was also found in bacteroids from root nodule and soluble glycine content was relativiely smaller than other amino acids in soybean nodule extracts.

  • PDF

A report of 44 unrecorded bacterial species isolated from Nakdong River in Korea

  • Ju-Hyung Jeon;Sanghwa Park;Ja Young Cho;Soo-Yeong Lee;Seoni Hwang;Jun Sung Kim;Eui-Jin Kim ; Ji Young Jung
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.3
    • /
    • pp.308-324
    • /
    • 2023
  • This study investigated unrecorded freshwater bacterial species in Korea. Water and sediment samples were collected from the Nakdong River basin from 2020-2022. Bacterial isolates obtained through the conventional culture method with commercial media were subjected to 16S rRNA gene sequencing to identify unrecorded bacterial species. Results of 16S rRNA gene sequencing of the bacterial isolates revealed that a total of 44 bacterial isolates shared 16S rRNA gene sequence similarities of more than 98.65%, with validly published bacterial species not reported in Korea yet. These isolates were phylogenetically assigned to 4 phyla, 7 classes, 21 orders, 33 families, and 42 genera. A total of 2, 6, 12, and 24 species belonged to phyla Bacillota, Bacteroidota, Actinomycetota, and Pseudomonadota, respectively. Here, we provide details of these 44 unrecorded bacterial species, including Gram staining, colony and cellular morphologies, biochemical properties, and phylogenetic position.

Microbial Contamination of Masks Worn by Healthcare Professionals (일부 의료기관 종사자가 사용한 마스크의 미생물 오염 사례)

  • Hyekyung Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.395-402
    • /
    • 2023
  • Objectives: Microbial contamination of face masks used by healthcare professionals can vary depending on the degree of exposure to bioaerosols in various healthcare environments. However, research on this topic is limited. Therefore, we analyzed microbial contamination of N95 respirators used in hospital offices, wards, and outpatient settings. Methods: Samples isolated from N95 respirators worn for 2, 4, and 6 hours were incubated at a temperature of 35-37℃ or 25-28℃ for 24 hours or for 3-7 days, and colony-forming units were counted in chocolate agar, tryptic soy agar, and Sabouraud dextrose agar plates. Total indoor airborne bacteria were also measured in the healthcare environments. Finally, microbial species were identified using Gram staining with a microscopic speculum. Results: The three types of environments did not deviate from the maintenance of standard indoor air quality. There was no difference between the microbial species identified in the healthcare environment and mask contamination. However, the number of bacteria in the masks worn in each environment differed, and the degree of contamination increased with mask-wearing time (p<0.05). Conclusions: Therefore, care must be taken to avoid recontamination of masks due to improper use and exposure to biological hazards in healthcare environments. In conclusion, scientific evidence is necessary for safe mask-wearing times. Based on the results of this study, we hope to conduct further research to establish guidelines for the safe use of face masks during respiratory disease epidemics.