• 제목/요약/키워드: Micro-mechanical model

검색결과 444건 처리시간 0.022초

압력 변화 모사를 통한 초소형 연소기에서의 열손실 예측 모텔 개발 (Development of Model for Heat Loss from a Micro Combustor Using Pressure Simulation)

  • 최권형;권세진;이대훈
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2003
  • As the size of a combustor decreases to a MEMS scale, heat loss increases and becomes a dominant effect on the performance of the devices. Existing models, however, are not adequate to predict the heat transfer and combustion processes in such small scales. In the present study, a semi-empirical model to calculate heat loss from a micro combustor is described. The model derives heat transfer coefficients that best fits the heat loss characteristics of a micro combustor that is represented by transient pressure record after combustion is completed. From conservation of energy equation applied to the burned gas inside the combustor, a relationship between pressure and heat transfer is reduced. Two models for heat transfer coefficients were tested; a constant and first order polynomial of temperature with its coefficients determined from fitting with measurements. The model was tested on a problem of cooling process of burnt gas in a micro combustor and comparison with measurements showed good agreements. The heat transfer coefficients were used for combustion calculation in a micro vessel. The results showed the dependence of flame speed on the scale of the chamber through enhanced heat loss.

자기 디버링을 이용한 복합 미세패턴의 형상 정밀도 향상 (A Study on Accuracy Improvement of Dual Micro Patterns Using Magnetic Abrasive Deburring)

  • 진동현;곽재섭
    • 대한기계학회논문집A
    • /
    • 제40권11호
    • /
    • pp.943-948
    • /
    • 2016
  • 최근, 산업에서는 미세패턴의 효과가 입증됨에 따라 미세패턴에 대한 연구가 활발히 진행되고 있다. 그러나, 이러한 연구들은 단일 패턴에 집중되어있으며, 복합 미세패턴의 제작 및 디버링에 관한 연구는 부족한 실정이다. 따라서, 본 연구에서는 원통형 공작물에 복합 미세패턴을 제작하고, 자기 디버링을 이용하여 디버링을 실시하였다. 또한, 반응표면법을 이용하여 패턴의 높이에 대한 예측모델을 도출하고, 자기 디버링 공정을 최적화하였다. 그 결과, 패턴의 높이에 대한 예측값과 실험값을 비교하였을 때, 평균적으로 7%의 오차가 발생하는 것을 확인하였다. 또한, 검증실험을 통하여 형상 정밀도가 우수한 복합 미세패턴의 제작이 가능하고, 예측모델이 신뢰성이 있음을 알 수 있었다.

On the size-dependent behavior of functionally graded micro-beams with porosities

  • Amar, Lemya Hanifi Hachemi;Kaci, Abdelhakim;Tounsi, Abdelouahed
    • Structural Engineering and Mechanics
    • /
    • 제64권5호
    • /
    • pp.527-541
    • /
    • 2017
  • In this work, a new hyperbolic shear deformation beam theory is proposed based on a modified couple stress theory (MCST) to investigate the bending and free vibration responses of functionally graded (FG) micro beam made of porous material. This non-classical micro-beam model introduces the material length scale coefficient which can capture the size influence. The non-classical beam model reduces to the classical beam model when the material length scale coefficient is set to zero. The mechanical material properties of the FG micro-beam are assumed to vary in the thickness direction and are estimated through the classical rule of mixture which is modified to approximate the porous material properties with even and uneven distributions of porosities phases. Effects of several important parameters such as power-law exponents, porosity distributions, porosity volume fractions, the material length scale parameter and slenderness ratios on bending and dynamic responses of FG micro-beams are investigated and discussed in detail. It is concluded that these effects play significant role in the mechanical behavior of porous FG micro-beams.

좌굴과 상변화를 이용한 Micro Actuator의 개발 및 해석 (Development and Analysis for Micro Actuator Using Buckling Membrane and Phase Change)

  • 송귀은;김정식;김광호;이윤표
    • 대한기계학회논문집B
    • /
    • 제28권6호
    • /
    • pp.638-645
    • /
    • 2004
  • A new micro actuation concept is introduced and studied in this paper. This idea is based on the thermo-pneumatic actuation principle. In order to improve the performance of a conventional thermo-pneumatic actuator, the idea of bistable buckling is added. By using a membrane which has the bistable buckling characteristics, the working pressure difference can be increased and as a result the work output can be increased. The analysis model for each phenomenon, bistable buckling and phase change, are suggested and the each model is verified with experimental data. From the comparison of the theoretical prediction with the experimental results, it can be concluded that these models are useful for such micro actuator analysis.

대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석 (Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis)

  • 원예연;백명현;최문권;전경진;김만경
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.519-523
    • /
    • 2004
  • 골다공증이 있는 대퇴골두 해면골과 골다공증이 없는 대퇴골두 해면골의 특성을 평가하고자 미세단층촬영기 및 유한요소모델을 이용하여 해면골을 미세구조 특성과 기계적 특성을 비교 및 분석하였다. 골다공증이 있는 대퇴골두는 골밀도를 측정하여 T-score 값이 -2.5 이상인 시편 15개를 사용했으며, 골다공증이 없는 대퇴골두는 사망전 골다공증으로 인한 병력이 없었던 사체 4구에서 대퇴골두 5개를 획득하여 사용하였다. 대퇴골두 해면골의 미세구조 특성을 분석하기 위해서 미세단층촬영기를 이용하여 골다공증이 있는 대퇴골두와 골다공증이 없는 대퇴골두를 촬영하여 형태학적 지수(histomorphometry index)를 구했고, 미세단층촬영기에 의해서 획득된 미세영상(pixel size=21.31㎛)을 바탕으로 유한요소모델을 재건하여 기계적 특성을 구하였다. 형태학적지수는 골다공증이 없는 대퇴골두가 골다공증이 있는 대퇴골두에 비해서 골소주 두께, 골 체적, 골 체적비, 이방성 정도 그리고 골소주 개수가 증가했으며, 골소주 간격과 구조모델지수는 감소했다. 기계적특성 지수는 골다공증이 없는 대퇴골두 해면골 시편에서 반력, 표면응력 그리고 영률이 높게 분석되었다. 골다공증이 있는 대퇴골두 해면골 시편에서 미세구조 특성이 퇴화되며, 기계적 특성이 감소된다는 사실을 알수 있었다.

유한요소 모델 변수의 역 추정법을 이용한 생체의 물성 규명 (Biomechanical Characterization with Inverse FE Model Parameter Estimation: Macro and Micro Applications)

  • 안범모;김영진;신현정;김정
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1202-1208
    • /
    • 2009
  • An inverse finite element (FE) model parameter estimation algorithm can be used to characterize mechanical properties of biological tissues. Using this algorithm, we can consider the influence of material nonlinearity, contact mechanics, complex boundary conditions, and geometrical constraints in the modeling. In this study, biomechanical experiments on macro and micro samples are conducted and characterized with the developed algorithm. Macro scale experiments were performed to measure the force response of porcine livers against mechanical loadings using one-dimensional indentation device. The force response of the human liver cancer cells was also measured by the atomic force microscope (AFM). The mechanical behavior of porcine livers (macro) and human liver cancer cells (micro) were characterized with the algorithm via hyperelastic and linear viscoelastic models. The developed models are suitable for computing accurate reaction force on tools and deformation of biomechanical tissues.

API X65 강의 인장 및 굽힘 시편에 대한 유한요소 연성파괴 해석 (Finite Element Ductile Failure Simulations of Tensile and Bend Bars made of API X65 Steels)

  • 오창균;진태은;김윤재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1696-1701
    • /
    • 2007
  • This paper presents a micro-mechanical model of ductile fracture for the API X65 steel using the Gurson-Tvergaard-Needleman (GTN) model. Experimental tests and FE damage simulations using the GTN model are performed for smooth and notched tensile bars, from which the parameters in the GTN model are calibrated. As application, the developed GTN model is applied to simulate small-sized, single-edge-cracked tensile and bend bars, via three-dimensional FE damage analyses. Comparison of FE damage analysis results with experimental test data shows overall good agreements.

  • PDF

혈관 삽입용 초소형 작동형 내시경의 개발(II) - 시스템 설계, 제작 및 체외 성능 분석 - (Development of Intravascular Micro Active Endoscope(II) -System Design, Fabrication and In-vitro Evaluation-)

  • 장준근;정석;이용구
    • Tribology and Lubricants
    • /
    • 제15권3호
    • /
    • pp.278-286
    • /
    • 1999
  • To predict the behavior of the intravascular micro active endoscope in the real human vascular system, a human mock circulation system was developed. The intravascular micro active endoscope which consists of micro active bending catheter and micro drug infusion catheter was driven in the velocity, Re number and temperature controlled flow. The three SMA (Shape Memory Alloy) zigzag type spring in the micro active bending catheter was heated by the electric current generated by PWM controller, and the shape memory effect made the actuator bend to any direction. The micro drug infusion catheter was driven through the inner hole of the micro active bending catheter. A mock circulation system is shaped from Ascending Arota to Femoral artery according to a human data (the data contains many vascular sizes and hydrographs of many control points). We developed a vascular model with glass and silicone tubes, and set the flow system with circulation parts, flow settling parts, and lots of valves. The heater and heat-controller was added to the How system to centre! the temperature of the How at 36.5$^{\circ}C$. The result showed that the developed intravascular micro active endoscope could be induced to any point in the vascular model.

An analytical study on free vibration of magneto electro micro sandwich beam with FG porous core on Vlasov foundation

  • Kazem Alambeigi;Mehdi Mohammadimehr;Mostafa Bamdad
    • Advances in nano research
    • /
    • 제15권5호
    • /
    • pp.423-439
    • /
    • 2023
  • The aim of this paper is to investigate the free vibration behavior of the micro sandwich beam composing of five layers such as functionally graded (FG) porous core, nanocomposite reinforced by carbon nanotubes (CNTs) and piezomagnetic/piezoelectric layers subjected to magneto electrical potential resting on silica aerogel foundation. The effect of foundation has been taken into account using Vlasov model in addition to rigid base assumption. For this purpose, an iterative technique is applied. The material properties of the FG porous core and FG nanocomposite layers are considered to vary throughout the thickness direction of the beams. Based on the Timoshenko beam theory and Hamilton's principle, the governing equations of motion for the micro sandwich beam are obtained. The Navier's type solution is utilized to obtain analytical solutions to simply supported micro sandwich beam. Results are verified with corresponding literatures. In the following, a study is carried out to find the effects of the porosity coefficient, porous distribution, volume fraction of CNT, the thickness of silica aerogel foundation, temperature and moisture, geometric parameters, electric and magnetic potentials on the vibration of the micro sandwich beam. The results are helpful for the design and applications of micro magneto electro mechanical systems.

미기압파 저감을 위한 고속전철 열차-터널 조건의 근사최적설계 (Approximate Optimization of High-speed Train Shape and Tunnel Condition to Reduce the Micro-pressure Wave)

  • 김정희;이종수;권혁빈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1023-1028
    • /
    • 2004
  • A micro-pressure wave is generated by the high-speed train which enters a tunnel, and it causes explosive noise and vibration at the exit. It is known that train speed, train-tunnel area ratio, nose slenderness and nose shape mainly influence on generating micro-pressure wave. So it is required to minimize it by searching optimal values of such train shape factors and tunnel condition. In this study, response surface model, one of approximation models, is used to perform optimization effectively and analyze sensitivity of design variables. Owen's randomized orthogonal array and D-optimal Design are used to construct response surface model. In order to increase accuracy of model, stepwise regression is selected. Finally SQP(Sequential Quadratic Programming) optimization algorithm is used to minimize the maximum micro-pressure wave by using built approximation model.

  • PDF