• 제목/요약/키워드: Micro-inverter

검색결과 113건 처리시간 0.142초

모터 파라미터 산포를 고려한 고속 운전에서의 속도제한 제어기 구현 (Implementation of Speed Limitation Controller Considering Motor Parameter Variation in High Speed Operation)

  • 김경훈;윤철;권우현
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1584-1590
    • /
    • 2017
  • This paper presents a implementation method of reliable speed limitation controller considering motor parameter variation in high speed operation. In spinning process of drum washing machine, speed increase has to be limited when unallowable imbalance mass is detected. Otherwise, severe noise and vibration can happen because noise and vibration are proportional to imbalance mass. To detect imbalance mass, d-axis current magnitude is used. However, we have to compensate for back-emf and power supply variation by means of detecting them because d-axis current is affected by both of them. On the other hand, we have to carefully estimate back-emf because back-emf is affected by stator resistance variation and inverter voltage error. Stator resistance variation can happen by manufacturing process for mass production or temperature variation in running. And there are inverter voltage errors between command voltage from micro-computer to inverter and real voltage from inverter to motor because of rising and falling time delay and turn-on resistance of power semiconductor switch. To solve this problem, we propose 2-step align current injection method which is to inject step-wise current right before starting. By this method, we can simply obtain stator resistance by ratio of voltage without inverter voltage error and current, and we can measure inverter voltage error. So we can obtain more exact model current, and then by simple calculation with compensation gain, we can estimate more accurate motor back-emf. We show that this method works well. It is verified through experiments.

인버터를 이용한 냉동용 압축기의 용량 제어 (Control of Refrigerating Compressor Capacity Using Inverter)

  • 양현석;김환성;김정훈;김상봉;김종수
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

대화면 LCD TV용 CCFL 병렬 구동에 관한 연구 (A Study on the CCFL Parallel Driving Circuit for the large LCD TV)

  • 장영수;윤석;권기현;한상규;홍성수;사공석진;노정욱
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.454-462
    • /
    • 2006
  • 현재 LCD 인버터의 경쟁력을 키우기 위해 인버터 하나로 다수의 램프를 병렬 구동하는 방식이 많이 사용되고 있다. 본 논문에서는 병렬 구동방식 중 Jin Balance와 O2Micro 방식에 대해 이론적으로 분석하고, 특히 각각의 램프 전류 편차를 일정하게 유지하기 위한 자화 인덕턴스 값의 설계에 대하여 설명하였다. 위의 결과를 이용하여 새로운 전류 평형 방식을 제안하고 수학적으로 분석하였으며, 모의실험을 통해 제안 방식의 정확성을 검증하였다.

인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어 (AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System)

  • 박귀근;최재원
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

시동기의 정 출력 시동 기법에 의한 마이크로터빈 시동 구간의 운전 시뮬레이터 개발 (Simulator for a Micro-Turbine during Start-up by Constant Power Output Motoring Method using Starter)

  • 노민식
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2028-2037
    • /
    • 2009
  • This paper presents the simulator for dynamic modeling of a MT(micro turbine) during start-up period. The simulator is implemented by modeling a dynamic power of main components of a MT including compressor, combustor and turbine. A modeling for a MT under steady state operation can be accurately built from thermodynamics analysis. But dynamic modeling during start-up period is very difficult because efficiency of main components is very low and the designed value has big error and nonlinear characteristics during start-up. In this paper, new method without using thermodynamics analysis during start-up is proposed for the simulator. The power models of main components are derived from analysis of the experimental operation data by test motoring using a electric starter under constant power output. The simulator is developed using MATLAB/Simulink. For constant power output control, sensorless vector inverter is designed and algorithms for starting from stall and method for controling a output power are proposed. The performance of developed simulator is verified by comparing experimental and simulation start-up results.

마이크로터빈과 연료전지의 EMTP-RV 모델링을 통한 마이크로그리드 내 동특성 분석 (Dynamic analysis of Microturbine and FuelCell in MicroGrid using EMTP-RV)

  • 서규석;주재현
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.42-48
    • /
    • 2010
  • The Microsource has to supply high quality Power that has high reliability and high energy efficiency to Load according to operating type of Microgrid. The energy sources of microsource type have various dynamic characteristic and transient response corresponding to classes and application skill. This paper shows dynamic characteristic of Microgrid according to Energy Source of microsource type. This research has been carried out by detailed modelling of Microturbine system and Fuelcell system. All models are realized by EMTP/RV and simulated change of operating type and load increase within Microgrid of DC constant voltage inverter model and Microturbine, Fuelcell based Microsource.

SoC 기반 보급형 MiC 스마트 태양광발전시스템 기술개발 (Technology Development of Entry-Level MiC Smart Photovoltaic System based on SOC)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권3호
    • /
    • pp.129-134
    • /
    • 2020
  • 최근 태양전지 모듈 내부에 습기 침투 및 EVA Sheet의 배부름 현상, 프레임 Seal이 녹아내리는 현상, 설치 후 1년 지난 모듈에서 발전성능이 저하되는 현상 등이 발생하고 있다. 국내에 5~7년 이전에 설치된 태양전지 모듈에서 백화현상 및 전극 부식 현상, 절연파괴 현상 등이 나타나기 시작하여 발전성능 저하로 이어지고, 장기 신뢰성 및 장수명 기술에 대한 커다란 문제점이 대두되고 있다. 따라서 이러한 문제점들을 해결하기 위해 태양전지 모듈의 내구성 확보 및 노화 진행을 모니터링할 수 있는 기능을 포함하는 마이크로 인버터 (MiCrco Inverter Converter, 이하 MiC) 개발 및 MiC에서 모니터링 데이터를 기반으로 태양전지 모듈의 노화를 판단할 수 있는 스마트 모니터링 프로그램이 제시되고 있다. 또한, 태양전지 모듈의 모니터링 기능을 강화한 MiC와 IT 융합을 통한 체계적 운영 관리를 통한 고효율 태양광 스마트 감시 시스템이 되기 위해서는 MiC 내의 SoC (System On Chip)는 태양전지 모듈에 대한 환경정보를 복합적으로 감지하고 필요시 통신 및 제어를 수행할 수 있는 기능들이 요구되고 있다. 이러한 요구사항들을 기반으로 본 논문에서는 SoC 기반 보급형 MIC 스마트 태양광발전시스템 기술개발을 목적으로 연구하고자 한다.

에어컨 인버터의 3차원 Vector제어 (Three dimensional vector control of airconditioner inverter)

  • 장재석;이장명
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.500-503
    • /
    • 1997
  • In this paper, we investigate the control methodology of inverter Airconditioner, using the three dimensional vector scheme. The method of three dimensional vector aims at the determination of optimal switching patterns for PWM to reduce switching loss and to improve the performance supplied voltage. The induction motors are widely used for home Airconditioners. These motors can be classified into two types: on or off control of Airconditioner and the speed control of motor. For speed control of motors, generally PWM methods are used. The PWM method based upon the modulation of triangular wave can not afford to supply line voltage to the motor sufficiently because of the capacity of processing speed of micro processors. Therefore airconditioner can not be operated efficiently. This problem can be solved with the method of three dimensional vector since it can increase the supplied voltage and maximum operating frequency of motor to 173V and 96Hz, respectively. As the result, this method shows 10 - 15% increase of voltage and 10% increase of operating frequency over the modulation of triangular wave. According to a theoretical study, the number of switching in the method of three dimensional vector is smaller than that of the modulation of triangular wave. The power consumption can be reduced and the supplied voltage can be increased. In other words, the efficiency of Airconditioner can be improved. We show that the method of three dimensional vector can supply higher voltage than the modulation of triangular method through the experiments and verify the degree of improvement of efficiency theoretically.

  • PDF

Modal Analysis of Resonance and Stable Domain Calculation of Active Damping in Multi-inverter Grid-connected Systems

  • Wu, Jian;Chen, Tao;Han, Wanqin;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.185-194
    • /
    • 2018
  • Interaction among multiple grid-connected inverters has a negative impact on the stable operations and power quality of a power grid. The interrelated influences of inverter inductor-capacitor-inductor filters constitute a high-order power network, and consequently, excite complex resonances at various frequencies. This study first establishes a micro-grid admittance matrix, in which inverters use deadbeat control. Multiple resonances can then be evaluated via modal analysis. For the active damping method applied to deadbeat control, the sampling frequency and the stable domain of the virtual damping ratio are also presented by analyzing system stability in the discrete domain. Simulation and experimental results confirm the efficiency of modal analysis and stable domain calculation in multi-inverter grid-connected systems.

마이크로 가스터빈 시험 장치 개발 (Development of Test Facility for Micro Gas Turbine)

  • 임형수;최범석;박무룡;황순찬;박준영;서정민;방제성;임영철;오인균;김병옥;조주형
    • 한국유체기계학회 논문집
    • /
    • 제18권5호
    • /
    • pp.42-48
    • /
    • 2015
  • To improve the core technology of the micro gas turbine, the performance test facility was developed. This paper is focusing on the explanation of the characteristics of micro gas turbine and its assist devices. Major part of micro gas turbine were radial type of compressor, annular type of combustor, radial type of turbine, thrust foil bearing, radial foil bearing and generator. The assist devices were consist of exhaust duct, inverter, data acquisition system, load bank and test cell. Before building up the test facility, the component test was previously conducted to confirm the component performance. After the test facility was prepared, the motoring test was conducted to investigate the rotor dynamic characteristics of the micro gas turbine. Also, the part load performance test was performed. With a developed micro gas turbine test facility, the improved core technology about the micro gas turbine can be suggested to the related industries.