• 제목/요약/키워드: Micro-Source

검색결과 589건 처리시간 0.034초

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Open Source를 이용한 MicroPACS의 구성과 활용 (Application of MicroPACS Using the Open Source)

  • 유연욱;김용근;김영석;원우재;김태성;김석기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.51-56
    • /
    • 2009
  • 목적 : Small-scalled PACS, Pc-based PACS로 표현되는 MicroPACS 시스템 구축에 대한 관심도가 급격하게 증가하고 있는 추세이다. MicroPACS 시스템은 PACS를 작은 규모에서 사용할 수 있도록 구성해놓은 것이고, 이 시스템을 구성하기 위해서는 DICOM viewer나 연결프로그램 등이 필요하다. 이것은 공개소스프로그램(Open Source Program)을 통해서 어느 누구나 쉽게 무료로 다운로드를 받을 수 있게 되어있다. 본 논문은 Open source program으로 MicroPACS를 직접 구성해보았고, 저장매체로서의 활용가치를 측정하기위하여 성능, 안정성 측면에서 기존의 광 저장매체(CD, DVDRAM)와 비교 분석하였다. 실험재료 및 방법 : 1. 소형 PACS를 구축하기 위해서 먼저 다음 기준에 맞는 DICOM Server Software를 검색한다. (1) 윈도우체제에서 사용가능할 것. (2) Free ware일 것. (3) PET/CT scanner와 호환되어야 할 것. (4) 사용하기 쉬워야 할 것. (5) 저장의 한계가 없어야 할 것. 2. (1) MicroPACS의 성능을 평가하기 위해 환자 1명의 Data ($^{18}F$-FDG Torso PET/CT)를 현재 Back-up장치로 쓰이는 광 저장매체(CD, DVD-RAM)와 MicroPACS에 저장하는데 소요되는 시간(Back up time)과 workstation으로 복구되기까지의 시간(Retrieval time)을 비교해 보았다. (2) PET/CT 검사를 시행했던 환자 1명의 병록번호와 검사 시행날짜를 핵의학과 직원 7명을 대상으로 알려주고 Data를 찾는데 소요되는 시간을 MicroPACS와 광 저장매체(CD, DVD-RAM)에서 각각 측정하여 비교하였다. 3. 기존의 백업장치로 쓰였던 CD들 중에서 2004년부터 2006년까지 500장을 무작위로 뽑아서 loading을 하였고 그중에서 얼마만큼의 에러가 발생하였는지를 측정하여 MicroPACS의 안정성을 비교평가하였다. 결과 : 1. Server와 DICOM viewer 기능을 갖춘 11개의 open source software 중에서 Conquest DICOM Server를 선택하였다. 2. (1) Backup과 Retrieval 시간 비교(단위 : 분)는 다음과 같다; DVD-RAM(5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) CD ($156{\pm}46$초), DVD-RAM ($115{\pm}21$초) and Conquest DICOM Server ($13{\pm}6$초). 3. 1년간 MicroPACS에서의 데이터손실은 없었으며(0%), 500장의 CD 중에서 14개(2.8%)가 Loading하는데 실패하였다. 결론 : 현재 많은 병원에서 도입되고 있는 Full PACS를 open source software를 통하여 소규모의 PACS로 재현해 보았고, 그 결과 가능하다는 결론이 나왔다. 데이터 저장의 유용성을 평가한 결과에서 MicroPACS를 이용하는 것이 기존의 광저장매체를 사용하는 것보다 효율적이고 작업속도가 향상 된다는 것을 확인할 수 있다.

  • PDF

교류전압 보상기능을 갖는 단상 마이크로 소스 시스템 (A Single-Phase Micro-Source System with a.c Voltage Compensation Capability)

  • 엄준현;정영국;임영철;김광헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.135-138
    • /
    • 2006
  • For compensating the a.c voltage variations of single-phase micro-source, micro-source system with a voltage compensator is proposed. Single phase p-q algorithm for calculating the a.c voltage variations of the micro-source is used. The effectiveness of the proposed the system is verified by the PSIM simulation in the steady state and transient state.

  • PDF

THE IMAGE CONFIGURATION OF MICRO LENSING WITH AN EXTENDED SOURCE

  • Chang, Kyong-Ae
    • 천문학회지
    • /
    • 제21권2호
    • /
    • pp.97-104
    • /
    • 1988
  • This study presents the specific rule governing the image configurations of an extended source for micro lensing of the two body gravitational lens system developed by Chang and Refsdal (1979). Various topological situations of a source are considered in relation to the regions bounded by the so-called critical curves.

  • PDF

백금 촉매가 증착된 미소돌기 전극과 유한 연료를 가지는 극소형 직접메탄을 연료전지의 제작 및 성능 평가 (Fabrication and Test of Micro Direct Methanol Fuels using Platinum Sputtered Microcolumn Electrodes with a Limited Fuel Source)

  • 서영호;조영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권4호
    • /
    • pp.218-224
    • /
    • 2004
  • We present a miniature Direct Methanol Fuel Cell (micro-DMFC) using platinum sputtered microcolumn electrodes with a limited amount of fuel. We use the microcolumn electrode in order to improve the power density of the micro-DMFC that consists of two electrodes and polymer electrolyte. We also design the built-in fuel chamber in the anode for the portable electronics applications. We design and fabricate both microcolumn and planar electrodes, having an identical projective area of 5mm${\times}$5mm. The diffusion current density of the microcolumn electrode is 1.73 times higher than that of the planar electrode at electrode potential of 1.1V in the half-cell test. The micro-DMFC based on the microcolumn electrodes shows the maximum power of 10.8$\pm$7.54㎼(43.23$\pm$0.16㎼/$\textrm{cm}^2$) at the projective area of 5mm${\times}$5mm, while the planar electrode micro-DMFC shows the maximum power of 0.81$\pm$0.42㎼(3.24$\pm$1.68㎼/$\textrm{cm}^2$) at the same projective area. The micro-DMFC based on the microcolumn electrodes shows 13 times higher power density that the micro-DMFC based on the planar electrodes does.

마이크로소스의 EMTDC 시뮬레이션 모델 개발에 관한 연구 (A Study on Developing the Simulation Model of Micro-Sources)

  • 손광명
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.24-32
    • /
    • 2005
  • 마이크로소스는 1[KW]${\sim}$수[MW] 사이의 전력을 공급하고, 기존의 대규모 발전설비보다 높은 신뢰도와 에너지 효율을 가지는 고품질의 전력을 공급할 수 있다. 이들은 크기가 작고 설치가 용이하여 빌딩, 산업체, 가정 등과 같은 수용가 측의 부하와 클러스터를 형성하여 마이크로그리드로 운전된다. 마이크로소스는 부하단의 전압 등의 전압품질을 제어하기 위하여 전압원형 인버터를 채용하고 있다. 본 논문에서는 다수의 마이크로소스가 계통에 연계되었을 때의 마이크로소스의 모델링 및 제어시스템의 특성에 관하여 연구하였다. 전력주파수 영역에서의 기본파 정상상태 인버터 모델을 이용한 마이크로소스의 EMTDC 모델을 개발하였으며, 이를 통해 마이크로소스의 제어시스템 파라미터에 따른 제어특성을 분석하였다. 컴퓨터 시뮬레이션을 통하여 제안된 모델의 효용성을 확인하였다.

마이크로그리드의 모델링 및 해석에 관한 기초 연구 (A Study on the Modeling and Analysis of the Micro-Grid)

  • 손광명;이계병
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.533-534
    • /
    • 2006
  • Micro-source units having power ratings in thousands of watts can provide power quality with higher reliability and efficiency than the conventional large scale units. This paper develops switching level model of micro-source and studies the characteristics of the micro-grid consisting of multiple micro-sources and interfaced with electric power system. The developed model adopts the space vector PWM to fully utilize the capacity of inverter. The interaction of the grid connected micro-sources and the characteristics of the control system parameters are investigated. Micro-sources and micro-grid are implemented using PSCAD/EMTDC. Simulation results show that the proposed model is efficient for studying micro-grid system.

  • PDF

초소형 동력 장치 (MEMS Power Device)

  • 권세진
    • 한국추진공학회지
    • /
    • 제12권1호
    • /
    • pp.64-70
    • /
    • 2008
  • 마이크로 가공기술의 눈부신 발달에 힘입어 다양한 항공우주 시스템을 초소형화 하려는 시도가 있어 왔다. 마이크로 비행체, 나노 위성, 마이크로 로봇 등의 개념들이 등장하였다. 이들 독립 이동식 마이크로 시스템을 구동하는 데에는 기존의 배터리 보다 훨씬 에너지 밀도가 높은 동력원이 필요하다. 그러나 이와 같은 고에너지 동력원이 아직 존재하지 않는다. 이 논문에서는 초소형 동력원 연구의 과거와 현재를 살펴보고, 미래 발전 방향에 대한 제안을 시도하였다.

서브마이크로 펄스 전압파형을 이용한 대기압 저온 마이크로 플라즈마 소스 개발 (The Development of Non-thermal Micro Plasma Source Under Atmospheric Pressure by Means of Submicrosecond Pulse Voltage Waveforms)

  • 최준영;이호준;김동현;이해준;박정후
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1802-1806
    • /
    • 2007
  • Nowadays, many configurations and applications of small atmospheric plasma source have been investigated with growing interest, as it provides the bacteria inactivation, the surface modification and removal of unwanted small regions, and so on. In this paper, the non-thermal micro plasma source under atmospheric pressure by means of submicrosecond pulse voltage waveforms is suggested. Plasma operates in helium is appears as a small (sub-mm) glow at the tip of a plasma gun. Electrical measurements show that the plasma source operates at low voltage (about 500V) and the power consumption is about 1W at 25kHz. Moreover, the emission spectrum shows the relatively higher emission intensity of oxygen particles than those of helium and nitrogen.

Development of a Low Power Micro-Ion Engine Using Microwave Discharge

  • Koizumi, Hiroyuki;Kuninaka, Hitoshi
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.842-848
    • /
    • 2008
  • In this study, we propose a novel micro-ion engine system. Single plasma source is used for both ion beam source and neutralizing electron source. By changing the electrical connection, either operation can be switched. This micro-ion engine system gives translation motion and attitude control to microspacecraft. The major objective of this study is verification of our concept. Small plasma source of 20 mm diameter was developed. Plasma was sustained by microwave power. Using this plasma source, ion beam extraction and electron emission was successively demonstrated.

  • PDF