• Title/Summary/Keyword: Micro-Post

Search Result 324, Processing Time 0.025 seconds

The Effect of Dimensions of Micro-post on Oleophobic Property (마이크로 기둥 구조의 크기가 소유성 특성 발현에 미치는 영향)

  • Kim, Nam-Kyung;Kim, Hae-Ji
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.91-96
    • /
    • 2018
  • The oleophobic property of surfaces modified with micro-post structures are investigated for a range of micro-post diameter ($11-23{\mu}m$) and pitch ($20-40{\mu}m$). The contact angle of an oil droplet on surfaces with various micro-post dimensions was calculated using the Cassie-Baxter model and did not show a good agreement with the measured contact angle. From measurement, the micro-post with diameter of $23{\mu}m$ and pitch of $32{\mu}m$ was found to have the highest contact angle ($134.3^{\circ}$).

Post-buckling analysis of geometrically imperfect tapered curved micro-panels made of graphene oxide powder reinforced composite

  • Mirjavadi, Seyed Sajad;Forsat, Masoud;Barati, Mohammad Reza;Hamouda, AMS
    • Steel and Composite Structures
    • /
    • v.36 no.1
    • /
    • pp.63-74
    • /
    • 2020
  • The present research investigates post-buckling behavior of geometrically imperfect tapered curved micro-panels made of graphene oxide powder (GOP) reinforced composite. Micro-scale effects on the panel structure have been included based on strain gradient elasticity. Micro-panel is considered to be tapered based on thickness variation along longitudinal direction. Weight fractions of uniformly and linearly distributed GOPs are included in material properties based on Halpin-Tsai homogenization scheme considering. Post-buckling curves have been determined based on both perfect and imperfect micro-panel assumptions. It is found that post-buckling curves are varying with the changes of GOPs weight fraction, geometric imperfection, GOP distribution type, variable thickness parameters, panel curvature radius and strain gradient.

Cut out effect on nonlinear post-buckling behavior of FG-CNTRC micro plate subjected to magnetic field via FSDT

  • Jamali, M.;Shojaee, T.;Mohammadi, B.;Kolahchi, R.
    • Advances in nano research
    • /
    • v.7 no.6
    • /
    • pp.405-417
    • /
    • 2019
  • This research is devoted to study post-buckling analysis of functionally graded carbon nanotubes reinforced composite (FG-CNTRC) micro plate with cut out subjected to magnetic field and resting on elastic medium. The basic formulation of plate is based on first order shear deformation theory (FSDT) and the material properties of FG-CNTRCs are presumed to be changed through the thickness direction, and are assumed based on rule of mixture; moreover, nonlocal Eringen's theory is applied to consider the size-dependent effect. It is considered that the system is embedded in elastic medium and subjected to longitudinal magnetic field. Energy approach, domain decomposition and Rayleigh-Ritz methods in conjunction with Newton-Raphson iterative technique are employed to trace the post-buckling paths of FG-CNTRC micro cut out plate. The influence of some important parameters such as small scale effect, cut out dimension, different types of FG distributions of CNTs, volume fraction of CNTs, aspect ratio of plate, magnitude of magnetic field, elastic medium and biaxial load on the post-buckling behavior of system are calculated. With respect to results, it is concluded that the aspect ratio and length of square cut out have negative effect on post-buckling response of micro composite plate. Furthermore, existence of CNTs in system causes improvement in the post-buckling behavior of plate and different distributions of CNTs in plate have diverse response. Meanwhile, nonlocal parameter and biaxial compression load on the plate has negative effect on post-buckling response. In addition, imposing magnetic field increases the post-buckling load of the microstructure.

Experimental and Numerical Study on the Capillary Performance of Non-Homogeneous Micro-Post Arrays (비 균일적 마이크로 원기둥 배열을 이용한 고성능 냉각 표면)

  • Byon, Chan;Kim, Sung Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1091-1097
    • /
    • 2013
  • In this article, an advanced cooling surface based on micro-post arrays with non-homogeneous configurations is investigated and compared with conventional micro-post arrays with homogeneous configuration. The capillary performance of micro-post arrays are characterized using the capillary rate of rise experiments and numerical simulations which take into account the meniscus curvature. The experimental and numerical results show that that the capillary performance of the micro-post wick can be significantly enhanced, compared with the homogeneous type wick, by employing non-homogeneous configurations. The capillary performance is shown to be primarily a function of the solid fraction and increases linearly with decreasing solid fraction, regardless of the wick configuration, when the solid fraction is larger than 0.25. However, the capillary performance is found to be significantly reduced when the solid fraction falls below approximately 0.25.

Analyzing nonlinear mechanical-thermal buckling of imperfect micro-scale beam made of graded graphene reinforced composites

  • Khalaf, Basima Salman;Fenjan, Raad M.;Faleh, Nadhim M.
    • Advances in materials Research
    • /
    • v.8 no.3
    • /
    • pp.219-235
    • /
    • 2019
  • This research is devoted to analyzing mechanical-thermal post-buckling behavior of a micro-size beam reinforced with graphene platelets (GPLs) based on geometric imperfection effects. Graphene platelets have three types of dispersion within the structure including uniform-type, linear-type and nonlinear-type. The micro-size beam is considered to be perfect (ideal) or imperfect. Buckling mode shape of the micro-size beam has been assumed as geometric imperfection. Modified couple stress theory has been used for describing scale-dependent character of the beam having micro dimension. Via an analytical procedure, post-buckling path of the micro-size beam has been derived. It will be demonstrated that nonlinear buckling characteristics of the micro-size beam are dependent on geometric imperfection amplitude, thermal loading, graphene distribution and couple stress effects.

Case Study of Treating Acne Scar Using Scar Regeneration Acupuncture Therapy and Micro-needle Therapy (흉터재생침과 미세피부침을 이용한 여드름 흉터의 치험례)

  • Lee, Ki-Su;Kim, You-Ra;Choi, Hyeong-Seok
    • Journal of Acupuncture Research
    • /
    • v.29 no.4
    • /
    • pp.81-91
    • /
    • 2012
  • Objectives : There are numerous methods in treating acne scar. On the contrary there are hardly any cases on treating acne scars through Korean medicine. By observing we compared how much acne scar was treated by scar regeneration acupuncture therapy and micro-needle therapy treatment through observing pre and post case photos, KAGS, KCADI and patient satisfaction. Results : By comparing pre and post procedure through acne scar grade criteria, total of 5 patients showed improvement and could see distinct change in skin comparing case photos. After comparing pre and post procedures, total of 5 patients showed improvements in figures of Korean acne index. 4 patients replied very satisfied and 1 replies satisfied on patient satisfaction survey. Conclusions : After observing patients satisfaction, and comparing case photos, acne scar grade criteria, korean acne index, it can be considered that scar regeneration acupuncture therapy and micro-needle therapy done in our clinic to be valid treatment.

Micro-current Treatment Effects on Pain, Balance of the Degenerative Knee Arthritis (미세전류치료가 퇴행성 무릎관절염 환자의 통증과 균형에 미치는 영향)

  • Chung, Joonsung;Cho, Namjeong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.3 no.2
    • /
    • pp.9-16
    • /
    • 2015
  • Purpose: The purpose of this research was to ascertain the effect of Micro-current on a pain, balance, of knee joint in the patients with degenerative arthritis. Method: The 30 subjects who had micro-current in this research and randomly assigned into two group, an experiment group and a control group. micro-current was applied to 15 subject in the experiment group after general physical therapy. experiment group was applies general therapies and micro-current stimulation. The measurement were analyzed by using SPSS(V.20). In order to compare the post to the amount of pre-changes and post-changes of each group, the paired t-test was used. The difference between the experiment group and the control group was analyzed by using the analysis of convariance. Results: The results of this study were as follows; 1) In VAS measures, the pain point was significantly decreased in both the experimental and the control group. 2) Mc Gill Pain Questionnaire(MPQ), the pain point was significantly decreased in both the experimental and the control group. 3) TUG measures, the second was significantly decreased in both the experimental and the control group. 4) Weight distribution measures, the authority was significantly decreased in both the experimental and the control group. Conclusion: The micro-current is considered a degenerative knee arthritis that can be presented as an effective physical therapy intervention.

3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation

  • Uzun, Ismail Hakki;Malkoc, Meral Arslan;Keles, Ali;Ogreten, Ayse Tuba
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.101-109
    • /
    • 2016
  • PURPOSE. To investigate the void parameters within the resin cements used for fiber post cementation by micro-CT (${\mu}CT$) and regional push-out bonding strength. MATERIALS AND METHODS. Twenty-one, single and round shaped roots were enlarged with a low-speed drill following by endodontic treatment. The roots were divided into three groups (n=7) and fiber posts were cemented with Maxcem Elite, Multilink N and Superbond C&B resin cements. Specimens were scanned using ${\mu}CT$ scanner at resolution of $13.7{\mu}m$. The number, area, and volume of voids between dentin and post were evaluated. A method of analysis based on the post segmentation was used, and coronal, middle and apical thirds considered separately. After the ${\mu}CT$ analysis, roots were embedded in epoxy resin and sectioned into 2 mm thick slices (63 sections in total). Push-out testing was performed with universal testing device at 0.5 mm/min cross-head speed. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Overall, significant differences between the resin cements and the post level were observed in the void number, area, and volume (P<.05). Super-Bond C&B showed the most void formation ($44.86{\pm}22.71$). Multilink N showed the least void surface ($3.51{\pm}2.24mm^2$) and volume ($0.01{\pm}0.01mm^3$). Regional push-out bond strength of the cements was not different (P>.05). CONCLUSION. ${\mu}CT$ proved to be a powerful non-destructive 3D analysis tool for visualizing the void parameters. Multilink N had the lowest void parameters. When efficiency of all cements was evaluated, direct relationship between the post region and push-out bonding strength was not observed.

MICRO-POST PROGRAM 소개

  • 이선구;이태연
    • Computational Structural Engineering
    • /
    • v.3 no.4
    • /
    • pp.35-36
    • /
    • 1990
  • 오늘날 유한요소해석 결과를 컴퓨터 그래픽을 활용하여 일목요연하게 후처리 함은 일반화 되어 있다. 그래픽을 이용하면 해석된 많은 수치 출력대신에 이해하기 쉬운 도면의 형태로 해석결과를 분석하거나, 모델의 기하학적 형태를 검토할 수 있게 되므로 시간과 노력을 대폭 절감할 수 있다. 그러나, 최근까지 유한소요 후처리는 대형컴퓨터와 이에 종속되는 고가의 도화처리 장비에 의존하여 왔다. 유한요소법을 이용한 해석시 발생하는 많은 수치출력을 고가의 도화장비가 아닌 저가의 도화장비에 출력하고자 하는 노력의 결과로 PC용 그래픽후처리 프로그램인 MICRO-POST가 개발되었다.

  • PDF

Microcomputer-Based Post-Processorfor Large Finite Element Analysis (대규모 유한요소해석에 활용되는 소형컴퓨터용 후처리 그래픽 프로그램)

  • 이성우;이선구;이태연
    • Computational Structural Engineering
    • /
    • v.2 no.4
    • /
    • pp.69-77
    • /
    • 1989
  • Until recently post-processing of finite element model has been heavily relied on expensive graphic peripheral devices. With the aid of inexpensive microcomputers, very economical post-processor graphics program called MICRO-POST has been developed. Model geometry or results of analysis for the unlimited meshes can be easily presented in a number of low-cost graphic devices. The paper presents the procedure obtaining the device-independent graphics, and the structure and functions of the program. It also describes efficient I/O scheme to overcome the memory limitation, and dialogue-type input technique to control the plot operation in an interactive manner. Through the post processing examples for the general purpose finite element programs, it demonstrates the usefulness of the program.

  • PDF