• Title/Summary/Keyword: Micro part

Search Result 682, Processing Time 0.036 seconds

Assessment of Micro Organic Pollutants Removal Using Advanced Water Treatment Process and Nanofiltration Process (고도처리공정과 나노여과공정에서의 미량유해물질 제거 평가)

  • Kang, Joon-Seok;Choi, Yang-Hun;Kwon, Soon-Buhm;Yu, Young-Beom
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.579-587
    • /
    • 2014
  • Various kinds of micro organic pollutants have frequently been detected from a water system. Therefore, it is considered to be very important part in the drinking water treatment system. And the research about removal process and processing efficiency have been being conducted briskly. In this study, the removal efficiency was evaluated using advanced water treatment process and nanofiltration process. The removal efficiency of nanofiltration process was very different according to physical and chemical characteristics of materials. The molecular weight of cutoff was the most influential factor in the removal efficiency. And when pKa value was higher than pH of raw water or Log Kow value was below 2, the removal efficiency of material was decreased. In case of oxidation reaction, the bigger the molecular weight of material was and the more hydrophobic a material was, the less oxidation reaction occurred. And the removal efficiency was decreased. Most unoxidized materials were removed by absorption. And the more actively oxidation reaction occurred by $H_2O_2$, the more absorption reaction increased.

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate(ESR) of diluted blood in dogs (개 회석혈의 적혈구침강율(ESR)에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Park, Young-jun
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.2
    • /
    • pp.41-49
    • /
    • 1989
  • The study was undertaken to obtain indirect values of volume of packed red cell (VPRC) without centrifugation, using the erythrocyte sedimentation rate (ESR) of diluted blood in dogs. ESRs of diluted blood using the diluent of autologous plasma in which formed numerous RBC-rouleau clumps, autologous serum in which formed a few RBC-rouleau clumps, and 5% dextrose or 6% sucrose solutions in which formed numerous RBC-aggregation clumps, were accelerated. But, ESR of diluted blood using the 0.9% saline, D-S, ACD-B, CDP or D-PBS solutions were sluggish, because erythrocytes were dispersed in these diluents. Reliable values of VPRC on the basis of the correlating regressive equation to the ESR could be derived from values of$60^{\circ}$-angled-micro-ESR/40 min in the mixture, four parts of 5% dextrose solution and one part of whole blood. In the ESR values of diluted blood with low ratio, 1:1~3:1, $60^{\circ}$-micro-ESR was higher than $60^{\circ}$-Wintrobe-ESR. But, in the diluted blood with high ratio, 4:1~5:1, there was no different ESR values. For an aid of practical use, authers suggested a list of the $60^{\circ}$-micro-ESR/40 min in the diluted blood with equivalent VPRC of whole blood.

  • PDF

Research on a Operation of a Balise System which Using Solar Energy includes Micro-power Wireless Loop Detector (태양열에너지를 이용한 미소전력 무선 루프 검지기 일체형 발리스 시스템 운영 실험에 관한 연구)

  • Lee, Jeong-jun;Yang, Doh-chul;Kim, Seong Jin;Han, Seung-hee;Park, Kwang-ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.6
    • /
    • pp.150-158
    • /
    • 2016
  • This paper is on a design of a new balise system which has a new functional part of a micro-power inductive wireless loop vehicle detector. The field test has processed and the data has analyzed for check the solar energy operable ability of the detect data interconnect sub-system which includes repeaters and field controllers. Instead of a railroad environment, 12 individual parking-lots are used for field test environment. As a result, in the condition of the designed system and the test environment, it is assumed that under 200 passing vehicles(train or tram) per day can be processed only with solar energy.

A Study on Generation and Operation of Dynamic Pattern at Micro-stereolithography using $DMD^{TM}$ ($DMD^{TM}$를 이용한 마이크로 광 조형 시스템에서 다이나믹 패턴 생성 및 구동에 관한 연구)

  • Kim H.S.;Choi J.W.;Ha Y.M.;Kwon B.H.;Won M.H.;Lee S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1214-1218
    • /
    • 2005
  • As demands for precision parts are increased, existing methods to fabricate them such as MEMS, LIGA technology have the technical limitations like high precision, high functionality and ultra miniaturization. A micro-stereolithography technology based on $DMD^{TM}$(Digital Micromirror Device) can meet these demands. In this technology, STL file is the standard format as the same of conventional rapid prototyping system, and 3D part is fabricated by stacking layers that are sliced as 2D section from STL file. Whereas in conventional method, the resin surface is cured as scanning laser beam spot according to the section shape, but in this research, we use integral process which enables to cure the resin surface at one time. In this paper, we deal with the dynamic pattern generation and $DMD^{TM}$ operation to fabricate micro structures. Firstly, we address effective slicing method of STL file, conversion to bitmap, and dynamic pattern generation. Secondly, we suggest $DMD^{TM}$ operation and optimal support manufacturing for $DMD^{TM}$ mounting. Thirdly, we examine the problems on continuous stacking layers, and their improvements in software aspects.

  • PDF

Dysregulated Expression Profiles of MicroRNAs of Experimentally Induced Cerebral Aneurysms in Rats

  • Lee, Hyung-Jin;Yi, Jin-Seok;Lee, Hong-Jae;Lee, Il-Woo;Park, Ki-Cheol;Yang, Ji-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.72-76
    • /
    • 2013
  • Objective : Cerebral aneurysm (CA) is an important acquired cerebrovascular disease that can cause catastrophic results. MicroRNAs (miRNAs) are small non-coding RNAs, playing essential roles in modulating basic physiologic and pathological processes. Currently, evidences have been established about biologic relationship between miRNAs and abdominal aortic aneurysms. However, biologic roles of miRNAs in CA formation have not been explained yet. We employed microarray analysis to detect and compare miRNA expression profiles in late stage of CA in rat model. Methods : Twenty-six, 7-week-old male Sprague-Dawley rats underwent a CA induction procedure. The control animals (n=11) were fed a normal diet, and the experimental animals (n=26) were fed a normal diet with 1% normal saline for 3 months. Then, the rats were sacrificed, their cerebral arteries were dissected, and the five regions of aneurysmal dilation on the left posterior communicating artery were cut for miRNA microarrays analysis. Six miRNAs (miRNA-1, miRNA-223, miRNA-24-1-5p, miRNA-551b, miRNA-433, and miRNA-489) were randomly chosen for validation using real-time quantitative PCR. Results : Among a set of differentially expressed miRNAs, 14 miRNAs were over-expressed more than 200% and 6 miRNAs were down-expressed lower than 50% in the CA tissues. Conclusion : The results show that miRNAs might take part in CA formation probably by affecting multiple target genes and signaling pathways. Further investigations to identify the exact roles of these miRNAs in CA formation are required.

A Development of Intelligent Electronic Device(IED) for Electric Power System applied embedded OS (임베디드 OS를 적용한 전력용 디지털 장치의 개발)

  • Oh, Jae-Hoon;Kwon, Hyo-Chul;Oh, Sung-Min;Hong, Jung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.936-937
    • /
    • 2008
  • As a micro computer or micro processor technology has been advanced, the essential part which consists of electric power system has been changed into intelligent electronic device(IED), that is one kind of embedded system. There are already many parts changed into digital from analog in control and maintenance devices of electric system. These trends make advanced and novel concepts of devices and systems, that we couldn't even imagine in the analog circumstances. Now, the rate's of change is comparatively slower than IT field that is mainly represented by mobile communication, but that is a big change in the history of electric industries. Some people in those field called it Power-IT, and there have been many kinds of researches. Accelerated systems to go digital, users always and continuously demand more convenient, practical, and new functions. So, a lot of electric system manufactures have had tasks realizing many kinds of functions in an electronic device. According to the high-end technologies in semi-conductor and micro-computer field, manufactures can fully satisfy almost all of customer's needs, but there are other kinds of problems, such as large amount of program code, increasing complexity in proportion with program amount, and the hardness of maintenance and revision of the program. So nowadays, the necessity of embedded OS was emerged as a solution, and many researchers and manufactures have concentrated on studies related to embedded OS and its application.

  • PDF

Down-regulation of miRNA-452 is Associated with Adriamycin-resistance in Breast Cancer Cells

  • Hu, Qing;Gong, Jian-Ping;Li, Jian;Zhong, Shan-Liang;Chen, Wei-Xian;Zhang, Jun-Ying;Ma, Teng-Fei;Ji, Hao;Lv, Meng-Meng;Zhao, Jian-Hua;Tang, Jin-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5137-5142
    • /
    • 2014
  • Adriamycin (ADR) is an important chemotherapeutic agent frequently used in treatment of breast cancer. However, resistance to ADR results in treatment failure in many patients. Recent studies have indicated that microRNAs (miRNAs) may play an important role in such drug-resistance. In the present study, microRNA-452 (miR-452) was found to be significantly down-regulated in adriamycin-resistant MCF-7 cells (MCF-7/ADR) compared with the parental MCF-7 cells by miRNA microarray and real-time quantitative PCR (RT-qPCR). MiR-452 mimics and inhibitors partially changed the adriamycin-resistance of breast cancer cells, as also confirmed by apoptosis assay. In exploring the potential mechanisms of miR-452 in the adriamycin-resistance of breast cancer cells, bioinformatics analysis, RT-qPCR and Western blotting showed that dysregulation of miR-452 played an important role in the acquired adriamycin-resistance of breast cancer, maybe at least in part via targeting insulin-like growth factor-1 receptor (IGF-1R).

A Scalable Real Time Location measuring System for High Speed Moving Objects (고속 이동체를 위한 확장성 있는 실시간 위치 측정 시스템)

  • Ahn, Si-Young;Park, Jun-Seok;Oh, Ha-Ryoung;Seong, Yeong-Rak
    • The KIPS Transactions:PartA
    • /
    • v.19A no.2
    • /
    • pp.85-92
    • /
    • 2012
  • In this paper, a highly scalable real-time locating system which can measure location of fast moving targets is proposed. Within the system, the location service area is partitioned into grids with squares which is referred to as a macro-cell. Also, a macro-cell is further partitioned into $N{\times}N$ micro-cells. In a micro-cell, location reference nodes are placed on every vertex and an arbitration node is placed on the center. When a mobile node tries to measure its location, it should first communicate with the arbitration nodes for granting location measurement operation. Therefore, within a micro-cell, only one granted mobile node can calculate its location by a series of communication with location reference nodes. To evaluate performance of the proposed system, the system is modeled and simulated. The simulation result shows that the proposed system requires small communication time for location measurement operation and produces small location calculation error for fast moving targets.

Development and transcription estimation of an automotive interior plastic part(HD Switch Panel) with no glossy etching pattern (무광부식 패턴을 갖는 자동차 내장부품인 HD Switch Panel의 제조 및 전사성 평가)

  • Kim, Young-Kyun;Kim, Dong-Hak;Son, Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3280-3286
    • /
    • 2009
  • In this paper, we designed and manufactured HD Switch Panel parts with micro-etched pattern. By using CAE analysis, we could predict weld-line positions and the amount of shrinkage during injection molding process. We measured the temperature distribution of the mold surface so that we could optimize the processing conditions such as mold temperature. In order to increase the transcription of micro-etched pattern, we applied the E-Mold technology and evaluated the effect of mold temperature on the surface quality. We concluded that the etched pattern was improved(more than 2.5$\to$1.5~1.7) through the measurement of surface gloss and the observation of both SEM and SPM images.

Characteristics of Microwelded BLU CCFL Electrode in Terms of Glass Beading Heat Treatment Temperature (미세 용접된 BLU CCFL 전극의 유리비딩 열처리 온도에 따른 접합부 특성)

  • Kim, Gwang-Soo;Kim, Sang-Duck;Kwon, Hyuk-Dong
    • Journal of Welding and Joining
    • /
    • v.27 no.4
    • /
    • pp.73-78
    • /
    • 2009
  • Characterization of the microweld CCFL electrode for the TFT-LCD backlight unit was carried out in terms of the glass beading heat treatment conditions. We evaluate the weld zone and parent metal of the microweld CCFL electrodes that were exposed to simulated glass beading heat treatment. The CCFL electrode was composed of the cup made with pure Ni, the pin made with pure Mo and the lead wire made with Ni-Mn alloy. Each part of the electrode was assembled together by micro spot welding process and then the assembled electrodes were exposed to simulated glass beading temperatures of $700^{\circ}C,\;750^{\circ}C$ and $800^{\circ}C$. The microstructures of the microweld CCFL electrode were observed by using optical microscope, scanning electron microscope and EDS. Micro-tensile and microhardness test were also carried out. The results indicated that the grain coarsening in the HAZs(heat affected zones) for both the cup-pin weld and pin-lead wire were exhibited and the grain coarsening of the HAZ for the cup and the lead wire was more obvious than the HAZ of the pin. The micro-tensile test revealed that the fracture occurred at the cup-pin weld zone for all test conditions. The fracture surface could be classified into two parts such as pin portion and cup portion including weld nugget. The failure was seemed to be initiated from the boundary between nugget and pin through the weld joint. The result of the microhardness measurement exhibited that the relatively low hardness value, about 105HV was recorded at the HAZ of the cup. This value was about 50% less than that of the original value of the cup. The reduction of the microhardness was considered as the cause of the grain coarsening due to welding process. It was also appeared that there was no change in electric resistance for the standard electrodes and heat treated electrodes.