• 제목/요약/키워드: Micro gas turbine

검색결과 140건 처리시간 0.027초

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 황성훈;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF

마이크로 터빈용 고온 포일 베어링 개발 (High Temperature Air Foil Bearings for Micro Turbine)

  • 김경수;김승우;이인
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.104-108
    • /
    • 2004
  • Micro turbine is an electric power generating system using a gas turbine whose rated power is under 300kW, and it is featured as a small, efficient. maintenance free and environment-friendly system. Air foil bearing has several advantages over conventional bearings for micro turbine because it is oilless and non-contact. Recently, air foil bearings for high temperature over $500^{\circ}C$ has been developed for the application of 65kW micro turbine system. In this paper, the development and current status are summarized in detail.

  • PDF

고체산화물 연료전지/마이크로 가스터빈 하이브리드 시스템의 성능 해석 (Performance Analysis of a Solid Oxide Fuel Cell/Micro Gas Turbine Hybrid System)

  • 양진식;송태원;김재훈;손정락;노승탁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.273-276
    • /
    • 2005
  • Performance analysis of a solid oxide fuel cell/micro gas turbine hybrid system is conducted at design-point and part-load conditions and its results are discussed in this study. With detailed considerations of the heat and mass transfer phenomena along various flow streams of the SOFC, the analysis based on a quasi-2D model reasonably predicts its performance at the design-point operating conditions. In case of part-load operations, performance of the hybrid system to three different operation modes(fuel only control, speed control, and VIGV control) is compared. It is found that the simultaneous control of both supplied fuel and air to the system with a variable MGT rotational speed mode is the optimum choice for the high performance operation. And then, the dynamic characteristics of a solid oxide fuel cell are briefly introduced.

  • PDF

희박예혼합 마이크로 가스터빈 연소기 형상에 따른 연소특성 및 NOx 배기특성에 관한연구 (Effect of the Combustor Geometries on Combustion and NOx Emission Characteristics in a Lean Premixed Micro Gas Turbine)

  • 최민성;원온누리;김민국;나종문;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.229-231
    • /
    • 2012
  • A numerical analysis of a lean premixed combustor in a micro gas turbine was carried out to investigate the correlation between the turbulent mixing and emission characteristics on the combustor geometries. The interaction between the burners, by flow direction and momentum, significantly influenced on the turbulent mixing and combustion characteristics. The vortex which was generated by thermal expansion was observed during the combustion process, this was distinguished from the combustor geometries. The results showed that these characteristics can affect the NOx emission.

  • PDF

분산형 Micro Gas Turbine 계통연계 전력품질 분석 (The power quality analysis of interconnection with the dispered Micro Gas Turbine)

  • 윤기갑;허광범;임상규;김상준;조형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.547-548
    • /
    • 2006
  • This paper deals with the power quality of Micro Gas Turbine(MGT) generation system which is connected with distribution system. Measurements to evaluate the power quality of MGT generation system are performed with parameters that are frequency, voltage change, harmonics and flicker and then Parameters are evaluated.

  • PDF

공기포일베어링에 지지된 마이크로가스터빈의 회전체동역학적 설계 (Rotordynamic Design of the Micro Gas Turbine Supported by Air Foil Bearings)

  • 김영철;한정완;김경웅;김수용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.662-667
    • /
    • 2003
  • This paper presents a performance analysis of the 1st generation bump foil journal bearings for the micro gas turbine TG75. Static performances such as load capacity and attitude angle are estimated by using soft elasto-hydrodynamic analysis technique, and dynamic performances such as stiffness and damping coefficients are estimated by perturbation method. Rotordynamic analysis for TG75 is performed by using the bearing analysis results. TG75 rotor has 2 horizontal and vertical directional natural modes due to the bearing stiffness characteristics. TG75 rotor will be stably operated between the 1st bending mode at 33000cpm and the 2nd bending mode at 85500cpm. Unbalance response analysis results satisfy the API vibration criteria.

  • PDF

초소형 가스터빈엔진 열전달 현상의 수치적 및 실험적 연구 (Numerical and Experimental Analysis of Micro Gas Turbine Heat Transfer Effect)

  • 서준혁;권길성;최주찬;백제현
    • 대한기계학회논문집B
    • /
    • 제39권2호
    • /
    • pp.153-159
    • /
    • 2015
  • 본 연구에서는 MEMS기술을 적용한 2W급 초소형 가스터빈엔진의 개발과 실제 연소 환경에서의 발전 가능성을 해석적, 실험적으로 입증하였다. 초소형 가스터빈엔진은 터보차저, 연소기, 발전기로 이루어져 있다. 터보차저는 각각 직경 10mm와 9mm의 MEMS 공정 압축기와 터빈으로 구성되어 있으며 발전코일 또한 MEMS공정으로 설계되었다. 제작된 압축기와 터빈은 정밀 기계 가공된 축과 공기 베어링으로 지지되고 회전하며, 회전축 끝단에 영구자석을 설치하여 발전을 하게 된다. 공기 베어링과 압축기를 통한 냉각 효과를 해석하여 연소기에서 발생한 열을 충분히 차단할 수 있는 것으로 분석되었고, 이를 실험을 통해 검증하였다.

500 W 급 마이크로 가스터빈 제너레이터용 환형 연소기의 특성에 관한 연구 (Study on the Characteristics of an Annular Combustor for a 500 W Class Micro Gas Turbine Generator)

  • 도규형;김태훈;한용식;김명배;최병일
    • 한국연소학회지
    • /
    • 제19권4호
    • /
    • pp.14-20
    • /
    • 2014
  • In the present study, an annular combustor for a 500 W class micro gas turbine generator was designed and its characteristics were investigated by using both numerical and experimental methods. For this purpose, geometrical configurations of the annular combustor were determined in the aspect of the aerodynamic and chemical consideration. Also, fluid flow and pressure drop characteristics in the combustor were numerically studied by using commercial tool, FLUENT. Based on the numerical results, the diameter and the angle of air admission holes in the primary zone were chosen to be 2.5 mm and $30^{\circ}$, respectively. Finally, an integrated test unit, which consisted of a compressor, combustor, turbine, and motor/generator, was developed in order to measure the combustor efficiency. As the temperature difference between the combustor inlet and the turbine inlet or the air mass flow rate increased, the combustor efficiency increased and it was over 90% when the air mass flow rate was larger than 7.30 g/s. It was shown that the annular combustor developed in this study met the design requirement for a 500 W class micro gas turbine generator.

200kW 급 마이크로 가스터빈의 운전특성 분석 (Analysis of Operating Characteristics of 200kW Class Micro Gas Turbine)

  • 김정호;강도원;김동섭
    • 대한기계학회논문집B
    • /
    • 제37권11호
    • /
    • pp.1015-1022
    • /
    • 2013
  • 본 연구에서는 현재 개발중인 200kW 급 마이크로 가스터빈의 운전 특성을 모사하였다. 세부적인 성능 데이터를 이용하여 부분부하 제어방식(터빈 입구온도 제어방식(constant TIT control)과 터빈 출구온도 제어방식(constant TET control))과 외기온도에 따른 성능 및 작동특성을 분석하였다. 넓은 운전 범위에 대하여 압축기 서지마진과 터빈 입출구 온도 같은 작동 파라미터의 민감도를 단위 연료량 변화에 따라 예측하였다. 정상상태 계산으로 부분부하 변동 시 최대서지마진의 감소에 대한 정보를 민감도 분석을 통해 알 수 있다.

대형병원 건물에 마이크로 가스터빈 적용을 위한 에너지성능 및 경제성 평가 (The Energy Performance & Economy Efficiency Evaluation of Micro Gas Turbine Installed in Hospital)

  • 김병수;홍원표
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.8-13
    • /
    • 2009
  • Feasibilities of the application of a micro gas turbine cogeneration system to a large size hospital building are studied by estimating energy demands and supplies. The energy demand for electricity is estimated by surveying and sorting the consumption records for various equipment and devices. The cooling heating, and hot water demands are further refined with TRNSYS and ESP-r to generate load profiles for the subsequent operation simulations. The operation of the suggested cogeneration system in conjunction with the load data is simulated for a time span of a year to predict energy consumption and gain profile. The simulation revealed that the thermal efficiency of the gas turbine is about 30% and it supplies 60% of the electricity required by the building. The recovered heat can meet 56% of total heating load and 67% of cooling, and the combined efficiency reaches up to 70%.