• Title/Summary/Keyword: Micro drop

Search Result 217, Processing Time 0.029 seconds

Experimental Study on the Thermal Performance of a Printed Circuit Heat Exchanger in a Cryogenic Environment (극저온 환경의 인쇄기판형 열교환기 열적성능에 대한 실험적 연구)

  • Kim, Dong Ho;Na, Sang Jun;Kim, Young;Choi, Jun Seok;Yoon, Seok Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.426-431
    • /
    • 2015
  • The advantages of a printed circuit heat exchanger (PCHE) are the compactness and efficiency derived from its heat-transfer characteristics; furthermore, a PCHE for which a diffusion bonding method was used during production can be applied to extreme environments such as a cryogenic condition. In this study, a micro-channel PCHE fabricated by diffusion bonding was investigated in a cryogenic environment regarding its thermal performance and the pressure drop. The test rig consists of an LN2 storage tank, vaporizers, heaters, and a cold box, whereby the vaporized cryogenic nitrogen flows in hot and cold streams. The overall heat-transfer coefficients were evaluated and compared with traditional correlations. Lastly, we suggested the modified heat-transfer correlations for a PCHE in a cryogenic condition.

On the Design of LED Dimming Control System for Optical Zoom Lens (광학 줌렌즈를 위한 LED 조명 제어 시스템 설계)

  • Min, Jun Hong;Kim, Min Ho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.65-70
    • /
    • 2014
  • This paper is to improve the problem of the LED dimming control system using the conventional PWM and DAC method. The conventional PWM method controls the average current to switch dimming signal. This method generates the flicker when controlling at a low current. In order to solve the problem, this system prevents the flicker with the DAC method. The LED is lit at micro-current flowing in the LED. And offset voltage is generated in the output of the DAC when the DAC output is very low voltage as 0V. This was resolved by the voltage drop of the output voltage to construct a negative offset circuit. In addition, the LED current can't flow as set values because of overheating of FET. In order to solve the problem, the 16 bits ADC in the microprocessor is a more accurate current control receives the LED current in comparison with the set value. Therefore, the LED dimming control system proposed in this paper showed the accurate and reliable more than conventional systems.

A Study on the Characteristics Analysis of Automotive Ballast System (자동차 조명장치용 고압 방전등 시스템의 특성해석에 관한 연구)

  • Lee, Do-Ho;Kim, Byeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.3795-3801
    • /
    • 2011
  • The mathematical simulation of voltage and current waveform of the discharge lamp is useful for the analysis and design of ballasting circuits. This paper proposes a mathematical model which has lamp power and negative voltage drop in discharge lamp. Simulation applying the proposed model has been done, and the results are compared with the experimental results. Furthermore, in the paper, the ballast components(core, transformer) was designed such that high intensity discharge could be optimized for the automotive, by applying a method simulation based design.

A Study on the Method of Transferring Metal Specimens for Real-time Transmission Electron Microscopy using Ultrasonic Treatment (초음파 처리 활용 실시간 투과전자현미경 관찰용 금속 시편 전사 방법에 관한 연구)

  • H. Kim
    • Transactions of Materials Processing
    • /
    • v.33 no.2
    • /
    • pp.118-122
    • /
    • 2024
  • Micro-electromechanical systems (MEMS) based in-situ heating holders have been developed to enable high resolution imaging of heat treatment analysis. However, unlike the standard 3 mm metal disk specimens used in the furnace-based heating holder and general transmission electron microscopy holder, the MEMS-based in-situ heating holder requires thin specimens that can be penetrated by electrons to be transferred onto the MEMS chip. Previously, focused ion beam milling was used to transfer metal specimens, but it has the disadvantage of being expensive and the risk of specimen damage due to gallium ions. Therefore, in this study, we devised a method of transferring metallic materials by ultrasonic treatment using a transmission electron microscopy specimen made by electro jet polishing. A 3mm electropolished metal disk was placed in an appropriate solution, ultrasonicated, and then drop casted. The transfer of the specimen was successful, but it was confirmed that dislocations were formed inside the specimen due to ultrasonic treatment. This study provides a novel method for transferring metallic materials onto MEMS chips, which is cost-effective and less gallium ion damaging to the specimen. The results of this study can be used to improve the efficiency of heat treatment analysis using MEMS-based in-situ heating holders.

A Study on the Safety Code Development of Gas Engine Micro Combined Heat and Power System (소형 가스엔진 열병합 발전시스템 안전기준 개발)

  • Kwon, Jun-Yeop;Kim, Min-Woo;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2021
  • Recently, as a solution to the sharp drop in "power reserve ratio", it is being converted to a microgrid that enables bi-directional transmission and distribution. A microgrid is composed of a small-scale distributed power supply and a load. As a representative technology of distributed power generation, there is a Micro Combined Heat and Power system applied to homes and buildings. In this study, a safety standard was developed by dividing the power generation system, cooling system, lubrication system, and exhaust system to derive safety standards for a small gas engine power generation system with a gas consumption less than 232.6kW (200,000 kcal/h). In the case of the power generation system, a filter was installed and the system was stopped by detecting gas leakage and abnormalities in engine speed or output and the cooling system is stipulated to stop the system in case of insufficient cooling water or overheating. The lubrication system monitors the pressure and temperature of the lubricating oil and stops the system when an abnormality occurs, and the exhaust gas emission concentration regulation value was specified in accordance with domestic and foreign standards. Through the results of this study, it is judged that the safety of the gas engine power generation system can be improved and it can contribute to the commercialization of products.

Introduction of CAX1 into 'Hongro' Apple via Agrobacterium tumefaciens (CAX1 유전자가 도입된 사과 '홍로' 형질전환체)

  • Kim, Jeong-Hee;Shin, Il Sheob;Cho, Kang-Hee;Kim, Se Hee;Kim, Dae-Hyun;Hwang, Jeong Hwan
    • Korean Journal of Breeding Science
    • /
    • v.42 no.5
    • /
    • pp.534-539
    • /
    • 2010
  • 'Hongro' is early-mid maturing cultivar with good quality like 'Tsugaru' and it has not preharvest drop. The CAX1 gene was introduced into Korean apple cultivar 'Hongro' by Agrobacterium tumefaciens LBA4404 harboring pBI121 to obtain transgenic apple with enhanced Ca level. The CAX1 gene playing the role of $H^+/Ca^{2+}$ transporter from Arabidopsis thaliana increases Ca concentration in several plants. Regenerated transgenic lines were confirmed by polymerase chain reaction (PCR) analysis and Southern blot analysis of genomic DNA for the existence of CAX1 gene. Southern blot analysis of 'Hongro' transformants showed that two putative transgenic lines were integrated with CAX1 gene in genomic DNA. The CAX1 comparative expression levels of two transgenic lines were higher than that of non-transformant evaluated by comparative quantification analysis using a real-time PCR. These two lines were multiplied in vitro, and micro-grafted on apple rootstocks 'M.9' in the isolated greenhouse. Since two years after micro-grafting, the fruits came into bearing. Compared to Ca level of the non-transgenic 'Hongro', that of the CAX1 transgenic 'Hongro' in the flesh and leaves was higher.

Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units (에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교)

  • Shin, Dongho;Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

Evaluation of gaseous concentrations, bacterial diversity and microbial quantity in different layers of deep litter system

  • Li, Jing;Wang, Jingyu;Wang, Fujin;Wang, Aiguo;Yan, Peishi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.2
    • /
    • pp.275-283
    • /
    • 2017
  • Objective: An experiment was conducted to investigate the environment of the deep litter system and provided theoretical basis for production. Methods: The bedding samples were obtained from a pig breeding farm and series measurements associated with gases concentrations and the bacterial diversity as well as the quantity of Escherichia coli, Lactobacilli, Methanogens were performed in this paper. Results: The concentrations of $CO_2$, $CH_4$, and $NH_3$ in the deep litter system increased with the increasing of depth while the $N_2O$ concentrations increased fiercely from the 0 cm to the -10 cm depth but then decreased beneath the -10 cm depth. Meanwhile, the Shannon index, the dominance index as well as the evenness index at the -20 cm layer was significantly different from the other layers (p<0.05). On the other hand, the quantity of Escherichia coli reached the highest value at the surface beddings and there was a significant drop at the -20 cm layer with the increasing depth. The Lactobacilli numbers increased with the depth from 0 cm to -15 cm and then decreased significantly under the -20 cm depth. The expression of Methanogens reached its largest value at the depth of -35 cm. Conclusion: The upper layers (0 cm to -5 cm) of this system were aerobic, the middle layers (-10 cm to -20 cm) were micro-aerobic, while that the bottom layers (below -20 cm depth) were anaerobic. In addition, from a standpoint of increasing the nitrification pathway and inhibiting the denitrification pathway, it should be advised that the deep litter system should be kept aerobic.

Improvement of Handoff-state and QOS in Wireless Environment

  • Jeong, You-Sun;Choe, U-Gin
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • In this paper, we propose for improving QoS in wireless micro cellular network using Cellular-IP/PRC(Paging Route Cache) with Paging Cache and Route Cache in Cellular-IP and propose for performance of realtime and non-real time handoff service using Handoff state machine Paging Route Cache. Although the Cellular-IP/PRC technology is devised for mobile internet communication, it bas its vulnerability in frequent handoff environment. On the other hand, Cellular IP combines the capability of cellular networks to provide high performance handoff and efficient location management of active and idle mobile users with the inherent flexibility, robustness and scalability found in IP networks. Also Cellular-IP/PRC use semi-soft handoff. During semi-soft hand off a mobile host may be in contact with either of the old and new base stations and receive packets from them. Packets intended to the mobile node are sent to both base stations and buffered, so when the mobile host eventually moves to the new location it can continue to receive packets without interruption. It should be suitable for realtime service such as multimedia traffic. But, much waste of resource will occur in this method, especially for non-real time services such as FTP and E-mail. Therefore, a new algorithm that performs different handoff according to characteristic of each traffic by use of reserved field in IP packet is proposed in this thesis. This hand off state machine using differentiated handoff improves quality of services in Cellular-IP/PRC. Suggested algorithm shows better performance than existing technology in wireless mobile internet communication environment. Matlab simulation results are improving QoS, show call drop and call blocking provided to Paging Router Cache during handoff state machine in Cellular-IP/PRC.

Predictive Model of Micro-Environment in a Naturally Ventilated Greenhouse for a Model-Based Control Approach (자연 환기식 온실의 모델 기반 환기 제어를 위한 미기상 환경 예측 모형)

  • Hong, Se-Woon;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.181-191
    • /
    • 2014
  • Modern commercial greenhouse requires the use of advanced climate control system to improve crop production and to reduce energy consumption. As an alternative to classical sensor-based control method, this paper introduces a model-based control method that consists of two models: the predictive model and the evaluation model. As a first step, this paper presents straightforward models to predict the effect of natural ventilation in a greenhouse according to meteorological factors, such as outdoor air temperature, soil temperature, solar radiation and mean wind speed, and structural factor, opening rate of roof ventilators. A multiple regression analysis was conducted to develop the predictive models on the basis of data obtained by computational fluid dynamics (CFD) simulations. The output of the models are air temperature drops due to ventilation at 9 sub-volumes in the greenhouse and individual volumetric ventilation rate through 6 roof ventilators, and showed a good agreement with the CFD-computed results. The resulting predictive models have an advantage of ensuring quick and reasonable predictions and thereby can be used as a part of a real-time model-based control system for a naturally ventilated greenhouse to predict the implications of alternative control operation.