• Title/Summary/Keyword: Micro data storage

Search Result 89, Processing Time 0.022 seconds

On-axis servo control in pickup actuator for disk type holographic data storage (디스크 형 홀로그램 정보저장장치를 위한 광축상 서보 컨트롤)

  • Kim, Sung-Phil;Song, Seok-Ho;Oh, Cha-Hwan;Kim, Pill-Soo;Kim, Ji-Deog;Lee, Hong-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.58-64
    • /
    • 2003
  • In order to read correct data from a disk-type holographic storage medium, it is very important to implement a servo-control in the pick-up module, as in a conventional CD-ROM. We propose a novel servo-control method using a glass plate on the optical axis, which is able to compensate the mechanical errors coming from wobbling of holographic disk and spindle motor. By rotating the glass plate within $\pm$10 degrees, we can reduce the reading errors of $\pm$200 ${\mu}{\textrm}{m}$ to $\pm$15 ${\mu}{\textrm}{m}$.

Effect of dynamic range consumption for microholographic data storage system (마이크로 홀로그래픽 시스템에서 미디어의 소진효과)

  • Kim, Do-Hyung;Min, Cheol-Ki;Cho, Jang-Hyun;Kim, Nak-Yeong;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.31-35
    • /
    • 2011
  • In microholographic data storage system (MDSS), compact recording is required to achieve high capacity.[1] When the data is recorded, neighbor monomer is also affected by reaction at the focal point.[2,3] This unintended process caused more monomer consumption and degradation of total capacity. To avoid this extra consumption of dynamic range, it is required to define the effective dynamic range for MDSS. In this paper, we experimentally investigate the relation between dynamic range consumption and micro grating formation. Dynamic range consumption was monitored by real time read-out system. Micrograting was recorded with different consumption ratio and compared by diffraction efficiency of track direction. Finally, we define suitable dynamic range for MDSS.

Implementation of Dual Storage Device in Communication System (통신시스템에서의 이중화 저장장치의 구현)

  • 정재희;심재구;박병관;함종식;노승환
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.263-266
    • /
    • 2000
  • In this paper we develop a dual storage device to store a lot of data safely and reliably in communication system. The device consists of micro-controller, FPGA and hard disk. It provides many functions those are rebuilding, automatic remapping, host service and remote host service. The developed device can be used instead of expensive storage device like flash memory in various communication systems.

  • PDF

Micro Thermal Design of Swing-Arm Type Small Form Factor Optical Pick-up System (스윙 암 타입 초소형 광 픽업 시스템의 방열 설계)

  • Lee, Jee-Na;Kim, Hong-Min;Kang, Shin-Ill;Sohn, Jin-Seung;Lee, Myung-Bok
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.21-25
    • /
    • 2006
  • The new multimedia information environment requires smaller optical data storage systems. However, one of the difficulties encountered in designing small form factor(SFF) optical pick-up is to emit the heat which is generated from laser diode(LD). Heat generated at the LD can reduce the optical performance of the system and the lifetime of LD. Therefore, it is important to include the thermal design in the design stage of SFF optical pick-up system for high performance and the longer lifetime of LD, and furthermore, to analyze the thermal characteristics of LD in detail micro heat transfer analysis is necessary. In the present study, micro heat transfer analysis was performed using the finite element method for the $28{\times}11{\times}2mm^3$ super slim swing-arm type optical pick-up actuator for Blu-ray disk. Two different materials were used for a swing-arm; a double layer polycarbonate/steel structure and a single aluminum structure.

  • PDF

Electromagnetic Micro x-y Stage for Probe-Based Data Storage

  • Park, Jae-joon;Park, Hongsik;Kim, Kyu-Yong;Jeon, Jong-Up
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • An electromagnetic micro x-y stage for probe-based data storage (PDS) has been fabricated. The x-y stage consists of a silicon body inside which planar copper coils are embedded, a glass substrate bonded to the silicon body, and eight permanent magnets. The dimensions of flexures and copper coils were determined to yield $100{\;}\mu\textrm{m}$ in x and y directions under 50 mA of supplied current and to have 440 Hz of natural frequency. For the application to PDS devices, electromagnetic stage should have flat top surface for the prevention of its interference with multi-probe array, and have coils with low resistance for low power consumption. In order to satisfy these design criteria, conducting planar copper coils have been electroplated within silicon trenches which have high aspect ratio ($5{\;}\mu\textrm{m}$in width and $30{\;}\mu\textrm{m}$in depth). Silicon flexures with a height of $250{\;}\mu\textrm{m}$ were fabricated by using inductively coupled plasma reactive ion etching (ICP-RIE). The characteristics of a fabricated electromagnetic stage were measured by using laser doppler vibrometer (LDV) and dynamic signal analyzer (DSA). The DC gain was $0.16{\;}\mu\textrm{m}/mA$ and the maximum displacement was $42{\;}\mu\textrm{m}$ at a current of 180 mA. The measured natural frequency of the lowest mode was 325 Hz. Compared with the designed values, the lower natural frequency and DC gain of the fabricated device are due to the reverse-tapered ICP-RIE process and the incomplete assembly of the upper-sided permanent magnets for LDV measurements.

  • PDF

Data Management Plan for the KMTNet Project

  • Lee, Chung-Uk;Kim, Dong-Jin;Kim, Seung-Lee;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.221.1-221.1
    • /
    • 2012
  • The Korea Astronomy and Space Science Institute (KASI) is developing three 1.6m optical telescopes with $18k{\times}18k$ mosaic CCD cameras. These telescopes will be installed and operated at Chile, South Africa, and Australia for Korea Micro-lensing Telescope Network (KMTNet) project. The main scientific goal of the project is to discover earth-like extra-solar planets using the gravitational micro-lensing technique. To achieve the goal, each telescope at three sites will continuously monitor the specific region of Galactic bulge with 2.5 minute cadence for five years. Assuming 12 hour observation in maximum for a night, the amount of 200 GB file storage is required for one night observation at one observatory. If we consider the whole project period and the data processing procedure, a few PB class data storage, high-speed network, and high performance computers are essential. In this presentation, we introduce the KMTNet data management plan that handles gigantic data; raw image collecting, image processing, photometry pipeline, database archiving, and backup.

  • PDF

Fabrication of micro lens array using micro-compression molding (미세압축성형을 통한 플라스틱 미세렌즈의 성형)

  • Moon, Su-Dong;Kang, Shin-Il;Yee, Young-Joo;Bu, Jong-Uk
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.743-746
    • /
    • 2000
  • Plastic microlenses play an important role in reducing the size, weight, and the cost of the systems in the fields of optical data storage and optical communication. In the present study, plastic microlens arrays were fabricated using micro-compression molding process. The design and fabrication procedures for mold insert were simplified by using silicon instead of metal. A simple but effective micro compression molding process, which uses polymer powder, were developed for microlens fabrication. The governing process parameters were temperature and pressure histories and the micromolding process was controlled such that the various defects developing during molding process were minimized. The radius and magnification ratio of the fabricated microlens were $125{\mu}m$ and over 3.0, respectively.

  • PDF

Fabrication of Micro Lens Array Using Micro-Compression Molding (미세압축성형을 통한 플라스틱 미세렌즈의 성형)

  • Gang, Sin-Il;Mun, Su-Dong;Lee, Yeong-Ju;Bu, Jong-Uk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1242-1245
    • /
    • 2001
  • Plastic microlenses play an important role in reducing the size, weight, and the cost of the systems in the fields of optical data storage and optical communication. In the present study, plastic microlens arrays were fabricated using micro-compression molding process. The design and fabrication procedures for mold insert were simplified by using silicon instead of metal. A simple but effective micro compression molding process, which uses polymer powder, were developed for microlens fabrication. The governing process parameters were temperature and pressure histories and the micromolding process was controlled such that the various defects developing during molding process were minimized. The radius and magnification ratio of the fabricated microlens were 125$\mu\textrm{m}$ and over 3.0, respectively.

Design of Multiple Temperature Measurement Device for Performance Evaluation of Incubator (보육기 성능 평가를 위한 다접점 온도측정기의 설계)

  • Kim, W.K.;Kim, N.H.;Huh, J.M.;Yoo, S.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.86-88
    • /
    • 1991
  • A micro-computer based system has been designed to evaluate the performance of infant incubators. The measurement system used a hybrid of analog electronics for amplification, integration and switches and micro-computer for data storage, data display, and control of relay. This approach has been applied to measure the warm-up time, temperature stability, temperature change due to open/close of door and portholes, and temperature distribution on the mattress. The micro-computer provides on-line access of multi-point temperature data.

  • PDF