• Title/Summary/Keyword: Micro chamber

Search Result 242, Processing Time 0.03 seconds

Combustion Characteristics of Single Droplet of Diesel with Bio-diesel for Their Mixing Ratios and Sizes (경유와 바이오 디젤 액적의 혼합비율과 크기에 따른 연소특성)

  • Jeong, Man-Seok;Lee, Kyung-Hwan
    • Journal of Energy Engineering
    • /
    • v.18 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • The combustion characteristics of a single droplet of diesel and bio-diesel have been investigated experimentally with varying droplet size, ambient temperature and compound ratio in a high temperature chamber. The fuels used were diesel with bio-diesel contents varied from 0% to 100%. Each experiment has been performed from 970K to 1070K by 50K intervals. Imaging with a high-speed digital camera was adopted to measure the ignition delay and flame life-time, as well as to observe micro-explosion behavior. The increase of droplet size and decrease of furnace temperature cause an increase of the ignition delay time. As the bio-diesel content decreases, the ignition delay increases and the micro-explosion behavior is strengthened. It is also confirmed that the full combustion time decreases as the micro-explosion occurred.

Design and Analysis of Piezoelectric Micro-Pump Using Traveling-Wave (진행파를 이용한 압전 마이크로 펌프의 설계와 해석)

  • Na, Yeong Min;Lee, Hyun Seok;Park, Jong Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.567-573
    • /
    • 2014
  • Since the development of microelectromechanical systems (MEMS) technology for the medical field, various micro-fluid transfer systems have been studied. This paper proposes a micro-piezoelectric pump that imitates a stomach's peristalsis by using two separate piezoelectric elements, in contrast to existing micro-pumps. This piezoelectric pump is operated by using the valve-less traveling wave of peristalsis movement. If the piezoelectric plates at the two separated plates are actuated at the input voltage, a traveling wave occurs between the two plates. Then, the fluid migrates by the pressure difference generated by the traveling wave. Finite element analysis was performed to understand the mechanics of the combined system with piezoelectric elements, elastic structures, and fluids. The effects of design variables such as the chamber height and number of ceramics on the flow rate of the fluid were examined.

Fabrication of a Micro-thermoelectric Probe (마이크로 프로브 기반 열전 센서 제작 기술)

  • Chang, Won-Seok;Choi, Tae-Youl
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1133-1137
    • /
    • 2011
  • A novel technique for the fabrication of a glass micropipette-based thermal sensor was developed utilizing inexpensive thermocouple materials. Thermal fluctuation with a resolution of ${\pm}0.002$ K was measured using the fabricated thermal probe. The sensors comprise unleaded low-melting point solder alloy (Sn) as a core metal inside a borosilicate glass pipette coated with a thin film of Ni, creating a thermocouple junction at the tip. The sensor was calibrated using a thermally insulated calibration chamber, the temperature of which can be controlled with a precision of ${\pm}0.1$ K and the thermoelectric power (Seebeck coefficient) of the sensor was recorded from 8.46 to $8.86{\mu}V$/K. The sensor we have produced is both cost-effective and reliable for thermal conductivity measurements of micro-electromechanical systems (MEMS) and biological temperature sensing at the micron level.

Fabrication and Application of Micro Polymer Chip Platform for Rare Cell Sample Preparation (희귀 세포 샘플 준비를 위한 마이크로 폴리머 칩 플랫폼 제작 및 활용)

  • Park, Taehyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.217-222
    • /
    • 2018
  • In this paper, a new micro polymer chip platform and protocol were developed for rare cell sample preparation. The proposed platform and protocol overcome the current limitation of the dilution method which is based on statistics and the FACS method which expensive and requires fluorescence staining. It allows collecting exact number of target cells simply and selectively because the cells are visually confirmed during the collecting process. The collected cells can be transported or spiked into a desired locations, such as a microchamber, without cell loss. This research may applicable not only to a rare cell sample preparation for Lab on a Chip cancer diagnosis, but also to a single/double/multiple cell sample preparation for a cell analysis field. To verify this platform and protocol, five human breast cancer cells (MCF-7) were collected and transported into a hemocytometer chamber.

분만후 젖소의 자궁내 미생물상 조사 및 Lipopolysaccharide의 분리

  • 백광수;김태일;우제석;전병순;박수봉;김현섭;이현준;홍의철;안병석
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2003.10a
    • /
    • pp.119-119
    • /
    • 2003
  • 분만후 젖소의 자궁내 미생물상을 조사하고 미생물로부터 분리한 Lipopolysaccharide를 적용하여 소의 번식효율 증진에 기여하고자 분만후 젖소의 도축장 유래 자궁을 채취하여 혐기적 상태에서 균분리 동정을 실시하였다. 균분리 동정을 위하여, 시료를 1cm$\times$1cm로 채취하여 혐기상태에서 거품이 생길 때까지 vortexing한 후 균액 300$\mu l$를 뽑아 혐기배지에 도말하였고 도말한 plate는 $37{\circ}C$ 혐기chamber에서 24시간 배양하였다. 혐기배지에서 자란 균의 colony를 따서 Mac, BHI+B, BHI 배지에 배양한 후 Gram stain을 실시하였다. BHI 배지에서 자란 균의 colony를 따서 BUA+B 배지에 계대배양하였고 BUA+B 배지에서 자란 균중에 가장 마지막으로 자란 균을 따서 An-IF에 넣고 탁도를 63%T로 맞춘 후 An micro plate에 100$\mu l$씩 분주하였다. 분주한 plate를 $37{\circ}C$ 혐기 chamber에서 20~24시간 동안 배양한 후 Biolog를 실시하였다. 시료의 UV측정을 위하여 Sonic Processor로 세포를 분쇄하였고 분쇄한 세포를 $4{\circ}C$에서 10,000rpm으로 10분간 원심분리한 후 상층액을 분리하여 0.45$\mu m$ 필터로 여과한 다음 여과액을 취하여 UV로 standard(E.coli O26 B6 LPS)와 sample(10배 및 20배 희석액)을 측정하였다. (중략)

  • PDF

Painless Microjet Injector Using Laser Pulse Energy (레이저 펄스 에너지를 이용한 무통증 마이크로젯 약물전달시스템)

  • Yoh, Jai-Ick;Han, Tae-Hee;Hah, Jung-Moo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.547-550
    • /
    • 2011
  • We have developed a laser-based needle-free liquid drug-injection device. A laser beam is focused inside the liquid contained in the rubber chamber of a micro-scale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is less than 100 ${\mu}m$, and we verify that the injected microjet is fast enough to penetrate soft human tissue. In the experiment, the microjet penetrated a 5% gelatin-water solution that replicates the human thrombus and pork-fat tissue.

Catalytic Combustion Characteristics of Hydrogen-Air Premixture in a Millimeter Scale Monolith Coated with Platinum (밀리미터 스케일 촉매 연소기에서의 수소-공기 예혼합 가스의 촉매 연소 특성)

  • Choi, Won-Young;Kwon, Se-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.1
    • /
    • pp.20-26
    • /
    • 2005
  • In the present study, catalytic combustion of hydrogen-air premixture in a millimeter scale monolith coated with Pt catalyst was investigated. As the combustor size decreases, the heat loss increases in proportion with the inverse of the scale of combustion chamber and combustion efficiency decreases in a conventional type of combustor. Combustion reaction assisted by catalyst can reduce the heat loss by decreasing the reaction temperature at which catalytic conversion takes place. Another advantage of catalytic combustion is that ignition is not required. Platinum was coated by incipient wetness method on a millimeter scale monolith with cell size of $1{\times}1mm$. Using this monolith as the core of the reaction chamber, temperatures were recorded at various locations along the flow direction. Burnt gas was passed to a gas chromatography system to measure the hydrogen content after the reaction. The measurements were made at various volume flow rate of the fuel-air premixture. The gas chromatography results showed the reaction was complete at all the test conditions and the reacting species penetrated the laminar boundary layer at the honeycomb and made contact with the catalyst coated surface. At all the measuring locations, the record showed monotonous increase of temperature during the measurement duration. And the temperature profile showed that the peak temperature is reached at the point nearest to the gas inlet and decreasing temperature along the flow direction.

  • PDF

Catalytic Decomposition of Hydrogen Peroxide for Application on Micro Propulsion (마이크로 추력기 응용을 위한 과산화수소 촉매 분해 반응)

  • An Sung-Yong;Lee Jong-Kwang;Rang Seong-Min;Kwon Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.266-271
    • /
    • 2005
  • An experimental investigation of a microthruster using hydrogen peroxide as a monopropellant is described. The study comprises of preparation method of silver as a catalyst and performance evaluation of a catalytic reaction chamber. Silver was reduced in $H_2$ environment at $500^{\circ}C$. The catalytic reaction chamber was tested to determine the optimum configuration of the catalyst bed. The catalyst bed was made of a glass wafer substrate sputtered with silver and had a length of 20 mm. The conversion rate was measured with various residence time, catalyst bed temperature, catalytic coated area.

  • PDF

Differently expressed genes of soybean by ambient heat stress

  • Jung, Inuk;Kim, Jin Hyeon;Jung, Woosuk
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.156-156
    • /
    • 2017
  • Plants are grown under constitutive changing of environmental conditions and response to external conditions at both protein and transcription level. The effects of heat on plant growth are broad and influence the yield directly. Heat stresses could be classified depend on intensity and duration. Fundamental changes of growth condition by climate change maybe or maybe not classified as a stress on plant growth. The effects of a short and unanticipated impact of elevated heat on plant could be different with those of under longer extension of ambient heat. To examine differently expressed gene sets by ambient heat stress of soybean, we grow the soybean in normal condition for three weeks. After that, soybean plants move to growth chamber. The temperature of growth chamber increase up to $9^{\circ}C$ for four days. We have extracted mRNA and micro RNA every 24 hours and carried RNA sequence analysis. We found major metabolic pathways affected by ambient heat stress. Mainly carbon metabolism, translation machinery and amino acid synthesis are affected. We discussed the expression patterns of genes of heat sensing and hormone responses.

  • PDF

Development of a painless injector using high speed laser propulsion and its spin-off to medical industry (고속레이저추진원리를 활용한 무통증 주사기의 개발 및 의료산업으로의 Spin-off)

  • Han, Tae-Hee;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.326-330
    • /
    • 2010
  • A laser based needle-free liquid drug injection device has been developed. A laser beam is focused inside the liquid contained in the rubber chamber of micro scale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is 125 ${\mu}m$ and the injected microjet reaches an average velocity of 264 m/s. This device adds the time-varying feature of microjet to the current state of liquid injection for drug delivery.

  • PDF