• 제목/요약/키워드: Micro Pump

검색결과 186건 처리시간 0.03초

유류오염토양 처리를 위한 마이크로나노버블 토양세척에 관한 연구 (A Study on the Treatment of Oil Contaminated Soils with Micro-nano Bubbles Soil Washing System)

  • 최호은;정진희;한영립;김대용;정병길;최영익
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1329-1336
    • /
    • 2011
  • The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).

추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 도시규모 대기확산 실험을 위한 PFCs 추적자 방출 및 분석 시스템의 개발 및 적용 연구 (Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - An Improved Method for the Release and Determination of Perfluorocarbon Tracers in the Urban Atmosphere)

  • 유은진;이종범;노철언;김혜경;이강웅
    • 한국대기환경학회지
    • /
    • 제23권5호
    • /
    • pp.547-556
    • /
    • 2007
  • The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.

에너지 분배 기능을 이용한 마이크로 빛에너지 하베스팅 회로 (A Micro-Scale Photovoltaic Energy Harvesting Circuit Using Energy Distribution Technique)

  • 이신웅;이철우;양민재;윤은정;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.581-584
    • /
    • 2014
  • 본 논문에서는 에너지 분배 기능을 이용하여 MPPT(Maximum Power Point Tracking) 제어 기능을 구현한 마이크로 빛에너지 하베스팅 시스템을 제안한다. 소형 PV(Photovoltaic) 셀에서 출력되는 에너지와 전압 레벨은 작기 때문에 직접 MPPT 제어회로를 구동하기 어렵다. 따라서 제안된 회로에서는 시동회로를 사용하여 Vcp를 MPPT 제어회로를 구동하기 위해 필요한 전압까지 승압시킨다. Vcp가 원하는 전압 값에 도달하면 전압감지기가 이를 감지하여 PV 셀로부터 시동회로에 공급되는 에너지는 차단하고, 전력변환기에 에너지를 공급한다. Vcp가 감소하여 MPPT 제어회로가 동작하기 어렵게 되면 전력변환기로의 에너지 전달을 차단하고 시동회로를 다시 구동한다. 이렇게 에너지 분배 기능을 이용하여 시동회로와 전력변환기를 번갈아 동작시키면서 에너지를 수확하여 PMU(Power Management Unit)를 통해 부하에 전달한다. 제안된 회로는 0.35um CMOS 공정으로 설계 되었으며 모의실험을 통해 동작을 검증하였다. 설계된 회로의 칩 면적은 패드를 포함하여 $1430um{\times}1110um$이다.

  • PDF

탈세포화 기법을 이용한 돼지 바이오 스캐폴드: 환자 맞춤형 장기재생을 위한 역분화 줄기세포 동물모델 (Decellularized Bioscaffold of Pig Organs: A Tool for Patient-specific Organogenesis Using Induced Pluripotent Stem Cells)

  • 박경미;곽호현;남현숙;박인철;전용환;박성민;이승태;우제석;우흥명
    • 한국임상수의학회지
    • /
    • 제28권1호
    • /
    • pp.57-62
    • /
    • 2011
  • The shortage of transplantable kidneys has many efforts to regenerate bioartificial kidneys using transgenic animals and diverse kinds of scaffolds which are important tools for cell seeding. However, there are many limitations for clinical applications so far. Recently, decellularized bioscaffolds using animal organs come into spotlight because of its many superior advantages. In current study, we produced decellularized kidney bioscaffolds of pig which is an attractive animal as a clinical model for human. We decellularized pig kidneys with 1% SDS detergent solution using peristaltic pump systems for 12h. After decellularization process, the kidney bioscaffolds preserved intact 3D morphology including glomerular structure and almost DNA from pig was entirely removed. In addition, this process could preserve micro vascular network which is necessary for cell survival. Although, additional studies for recellularization and transplantation should be required, the decellular vascularized kidney bioscaffolds might have many potentials for kidney regeneration.

단열식 회전연료 노즐의 오리피스 직경에 따른 분무특성 연구 (A Study of Spray Characteristic with Orifice Diameter for Single Column Rotating Fuel Nozzle)

  • 장성호;최성만
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.253-256
    • /
    • 2009
  • 350Kw급 이하의 초소형 터보제트엔진에서 연료 미립화 특성을 만족하는 분사시스템을 개발하는 것은 매우 어려운 일이다. 그러나 회전 연료 분사시스템은 복잡한 고압연료펌프 시스템 없이도 엔진축의 원심력만을 이용함으로써 좋은 미립화를 할 수 있다. 이러한 이유로, 직경 40 mm의 매우 작은 회전식 연료 인젝터를 제작하였으며, 여러 가지 크기의 분사 오리피스에 대한 실험을 수행하였다. PDPA 측정 시스템을 사용하여 입자의 크기와 속도, 분무분포를 측정하였다. 실험 결과, 분사 오리피스로부터 분출된 단일 액주의 길이는 회전속도에 의해 제어되며, SMD는 회전수가 증가함에 따라 감소하고, 오리피스의 직경과 오리피스 내부에 생성되는 액막두께에 큰 영향을 받는다.

  • PDF

3D 프린터와 NodeMCU를 사용한 스마트 화분의 구현 (An Implementation of Smart Flowerpot made with 3D Printer and NodeMCU)

  • 나채빈;최연웅;김세광;서장규;황기태
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.231-237
    • /
    • 2017
  • 본 논문은 온도와 빛, 수분의 량을 탐지하여 자동으로 습도와 조도를 채워주는 스마트 화분을 만든 사례를 소개한다. 화분을 담는 용기는 3D 프린터로 제작하고, 용기의 내부에는 Wi-Fi가 내장된 NodeMCU 마이크로컨트롤러를 장착하였다. 온도와 습도, 조도를 감지하는 센서와, 펌프를 NodeMCU에 연결하고 제어 프로그램을 작성하여 NodeMCU 스스로 습도와 조도를 조절하도록 하였다. 또한 subscribe-publish 모델로 작동하는 MQTT 서버를 구축하고, NodeMCU와 본 연구에서 개발한 안드로이드 앱이 정보를 교환하도록 하였다. 안드로이드 앱의 사용자는 식물에게 적절한 온도, 습도, 조도를 스마트 화분에게 전달하고, 스마트 화분으로부터 현재 온도, 습도, 조도 정보를 모니터링 할 수 있게 하였다.

세포 기반 고집적 스크리닝 시스템용 비접촉식 고정밀 마이크로 디스팬서 제작 (Development of a Non-contact Liquid Dispenser for High Contents Screening System)

  • 조성진;김인태;임근배
    • 대한기계학회논문집A
    • /
    • 제40권6호
    • /
    • pp.581-585
    • /
    • 2016
  • 최근 고령화 사회에 진입과 소득수준이 향상됨에 따라 의료 수요가 빠르게 증가되고 있다. 이중 신약 개발은 의료분야의 핵심 분야 중 하나로 전 세계적으로 많은 투자가 연구가 이루어지고 있다. 신약 개발의 중요한 과제 중 하나는 다양한 후보를 빠르고 정확하게 발굴하는 자동화 시스템을 개발하는 것이다. 고속으로 후보물질을 발굴하는 기술 중 대표적 기술이 세포 기반 고집적 스크리닝 시스템(High Contents Screening, 이하 HCS) 기술이다. 이 HCS 시스템에서 다양한 물질을 한꺼번에 스크리닝하기 위해서는 다기능 고정밀 디스팬서 제작이 필수적이다. 본 연구에서는 기존의 HCS 디스팬서 시스템이 가지고 있는 단점을 보완하기 위해 에어건과 압력 구동식 펌프를 이용한 새로운 컨셉의 비접촉식 디스팬서를 개발하고 그 가능성을 확인한다.

An Active Voltage Doubling Rectifier with Unbalanced-Biased Comparators for Piezoelectric Energy Harvesters

  • Liu, Lianxi;Mu, Junchao;Yuan, Wenzhi;Tu, Wei;Zhu, Zhangming;Yang, Yintang
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1226-1235
    • /
    • 2016
  • For wearable health monitoring systems, a fundamental problem is the limited space for storing energy, which can be translated into a short operational life. In this paper, a highly efficient active voltage doubling rectifier with a wide input range for micro-piezoelectric energy harvesting systems is proposed. To obtain a higher output voltage, the Dickson charge pump topology is chosen in this design. By replacing the passive diodes with unbalanced-biased comparator-controlled active counterparts, the proposed rectifier minimizes the voltage losses along the conduction path and solves the reverse leakage problem caused by conventional comparator-controlled active diodes. To improve the rectifier input voltage sensitivity and decrease the minimum operational input voltage, two low power common-gate comparators are introduced in the proposed design. To keep the comparator from oscillating, a positive feedback loop formed by the capacitor C is added to it. Based on the SMIC 0.18-μm standard CMOS process, the proposed rectifier is simulated and implemented. The area of the whole chip is 0.91×0.97 mm2, while the rectifier core occupies only 13% of this area. The measured results show that the proposed rectifier can operate properly with input amplitudes ranging from 0.2 to 1.0V and with frequencies ranging from 20 to 3000 Hz. The proposed rectifier can achieve a 92.5% power conversion efficiency (PCE) with input amplitudes equal to 0.6 V at 200 Hz. The voltage conversion efficiency (VCE) is around 93% for input amplitudes greater than 0.3 V and load resistances larger than 20kΩ.

흡착제를 이용한 휘발성 유기물 채취 (Air Sampling For Volatile Organics Using an Adsorbent)

  • 조완근
    • 한국환경과학회지
    • /
    • 제1권1호
    • /
    • pp.41-46
    • /
    • 1992
  • 주거지역에서 대기오염물 시료채취에 대한 장기간 연구를 수행하기 위해서 휘발성 유기 화합물 분석에 적합한 24시간동안의 종합적인 공기시료를 채취하기 위해 공기시료 채취기가 제작되었다. 이 시료 채취기는 시료채취시 요구되는 모든 특성을 포함할 뿐만 아니라, 일반가정에 근접해서 설치되어야하므로 심미적 특성도 포함한다. 이 공기시료 채취기는 흡착제(티넥스)로 채워진 5/8인치 외경의 스테인레스 스틸 트랩 네개를 수용할수 있고, 분당 5-50 밀리리터의 범위에서 네 종류의 공기유속을 이용할수 있게 고안 되었다. 금속필도(10마이크로미터)가 트랩 어댑터의 입구에 직접 부착되었다. 부가적인 특성은 다음과 같다. : 1) 유기물질에 불활성인 재료로 제작 되었고, 2) 날씨에 영향을 받지 않고, 3) 전지를 이용하고, 4) 사람의 호흡영역에서 공기 시료를 채취하고, 그리고 5) 방음제로 싸여진 작은 펌프를 이용하여 조용하게 작동된다. 펌프/전지 장치는 시료채취기의 본체로부터 분리 되었다. 이 장치로 부터 야기되는 소음수준은 주거지역의 허용기준치(뉴저지주 환경보호국 기준)보다 낮았다. 이 공기시료 채취기는 일상 주거지역과 단층의 한 국민학교 옥상에서 성공적으로 작동되었다.

  • PDF

무밸브 마이크로 펌프의 성능평가를 위한 3차원 전기-유체-구조 상호작용 해석 (Three Dimensional Electro-Fluid-Structural Interaction Simulation for Pumping Performance Evaluation of a Valveless Micropump)

  • 팜마이;판반푸억;한철희;구남서
    • 한국항공우주학회지
    • /
    • 제37권8호
    • /
    • pp.744-750
    • /
    • 2009
  • 본 논문에서는 압전 작동기로 구동되는 무밸브 마이크로 펌프의 펌프 성능을 계산하였다. 선행연구에서 개발된 마이크로 펌프는 4층의 경량 압전 복합재료 작동기, PDMS로 된 챔버와 2개의 디퓨져로 이루어져 있다. 유한요소 해석은 압전 영역, 구조 영역 및 유체 영역을 완전 연성하여 수행되었다. 구조 및 압전 영역의 해석은 ANSYS를 사용하였으며, 유체영역의 해석은 ANSYS CFX를 사용하여 수행하였다. 작동 주파수가 10 Hz와 40 Hz인 경우에 대한 해석을 수행하여 작동 주파수가 유동 특성에 미치는 영향을 고찰하였다. 또한 300 Hz까지의 유동 해석을 통하여 작동 주파수에 따른 유량을 계산하였다.