• Title/Summary/Keyword: Micro Grid

Search Result 285, Processing Time 0.032 seconds

Spatio-temporal analysis of land price variation considering modifiable area unit problem (가변적 공간 단위의 문제를 고려한 지가 변동의 시공간 분석)

  • 오충원
    • Spatial Information Research
    • /
    • v.10 no.2
    • /
    • pp.185-199
    • /
    • 2002
  • The objective of this study is to investigate the suitable spatio-temporal analysis method considering the zoning effect of spatial analysis termed the modifiable areal unit problem(MAUP). In former studies of spatio-temporal analysis, there were disagreement between attribute data with spatial data, because of variation of administrative district aggregating attribute data. It is need to consider how the analysis zone effects spatial characteristics and spatio-temporal variation of urban region through land price variation analysis. This study considers MAUP through basic mesh system, which is composed of micro grid. Mesh system can solve disagreement of resolution between spatial data and attribute data.

  • PDF

Fuzzy Logic Based Energy Management For Wind Turbine, Photo Voltaic And Diesel Hybrid System

  • Talha, Muhammad;Asghar, Furqan;Kim, Sung Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.351-360
    • /
    • 2016
  • Rapid population growth with high living standards and high electronics use for personal comfort has raised the electricity demand exponentially. To fulfill this elevated demand, conventional energy sources are shifting towards low production cost and long term usable alternative energy sources. Hybrid renewable energy systems (HRES) are becoming popular as stand-alone power systems for providing electricity in remote areas due to advancement in renewable energy technologies and subsequent rise in prices of petroleum products. Wind and solar power are considered feasible replacement to fossil fuels as the prediction of the fuel shortage in the near future, forced all operators involved in energy production to explore this new and clean source of power. Presented paper proposes fuzzy logic based Energy Management System (EMS) for Wind Turbine (WT), Photo Voltaic (PV) and Diesel Generator (DG) hybrid micro-grid configuration. Battery backup system is introduced for worst environmental conditions or high load demands. Dump load along with dump load controller is implemented for over voltage and over speed protection. Fuzzy logic based supervisory control system performs the power flow control between different scenarios such as battery charging, battery backup, dump load activation and DG backup in most intellectual way.

CHANGE OF CHANNEL-FLOW TOPOLOGY BY A STREAMWISE-PERIODIC ARRAY OF ROTATING CIRCULAR CYLINDERS (주기적으로 배열된 회전하는 원형 실린더를 이용한 채널유동 토폴로지 변화)

  • Jeong, Taekyeong;Yang, Kyung-Soo;Lee, Kyongjun;Kang, Changwoo
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.17-24
    • /
    • 2013
  • In this study, we consider the characteristics of channel flow in the presence of an infinite streamwise array of equispaced identical rotating circular cylinders. This flow configuration can be regarded as a model representing a micro channel or an internal heat exchanger with cylindrical vortex generators. A numerical parametric study has been carried out by varying Reynolds number based on the bulk mean velocity and the cylinder diameter, and the gap between the cylinders and the channel wall for some selected angular speeds. An immersed boundary method was employed to facilitate implementing the cylinders on a Cartesian grid system. No-slip condition is employed at all solid boundaries including the cylinders, and the flow is assumed to be periodic in the streamwise direction. The presence of the rotating circular cylinders arranged periodically in the streamwise direction causes a significant topological change of the flow, leading to increase of mean friction on the channel walls. More quantitative results as well as qualitative physical explanations are presented to justify the effectiveness of rotating cylinders to modify flow topology, which might be used to enhance heat transfer on the channel walls.

A Study on the Initial Bonding Strength of Solder Ball and Au Diffusion at Micro Ball Grid Array Package (${\mu}BGA$ 패키지에서 솔더 볼의 초기 접합강도와 금 확산에 관한 연구)

  • Kim, Kyung-Seob;Lee, Suk;Kim, Heon-Hee;Yoon, Jun-Ho
    • Journal of Welding and Joining
    • /
    • v.19 no.3
    • /
    • pp.311-316
    • /
    • 2001
  • This paper presents that the affecting factors to the solderability and initial reliability. It is the factor that the coefficient of thermal expansion between package and PCB(Printed Circuit Board), the quantity of solder paste and reflow condition, and Au thickness of the solder ball pad on polyimide tape. As the reflow soldering condition for 48 ${\mu}BGA$ is changed, it is estimated that the quantity of Au diffusion at eutectic Sn-Pb solder surface and initial bonding strength of eutectic Sn-Pb solder and lead free solder. It is the result that quantitative measurement of Au diffusion quantity is difficult, but the shear strength of eutectic Sn-Pb solder joint is 842 mN at first reflow and increases 879 mN at third reflow. The major failure mode in solder is judged solder fracture. So, Au diffusion quantity is more affected by reflow temperature than by the reflow times.

  • PDF

ESS Connected PV Monitoring System Supporting Redundant Communications (통신 이중화를 지원하는 ESS연계 태양광 모니터링 시스템)

  • Joo, Jong-Yul;Lee, Young-Jae;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • The systems associated with the ESS never stop. It runs 24 hours everyday. The system must be managed to run. The ESS system should perform normally even if the power IT equipment fails or communication failure occurs. Therefore, there is a need for a system that actively addresses, manages and controls the high precision power data of the ESS, even if a variety of failures occur. I would like to propose a power management communication unit to cope with the occurrence of communication failure. This paper also includes an integrated management system that can perform micro grid site management, maintenance and monitoring for the ESS system connected with the solar power generation facility.

BGA to CSP to Flip Chip - Manufacturing Issues

  • Caswell, Greg;Partridge, Julian
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.04a
    • /
    • pp.27-34
    • /
    • 2001
  • The BGA Package has been the area array package of choice for several rears. Recently, the transition has been to finer pitch configuration called Chip Scale Packages (CSP). Several of these package types are available at 0.5 mm pitch, requiring surface mount assemblers to evaluate and optimize various elements of the assembly process. This presentation describes the issues associated with making the transition from BGA to CSP assembly. Areas addressed will include the accuracy of pick and piece equipment, printed wiring board lines and spaces, PWB vias, in-circuit test issues, solder paste printing, moisture related factors, rework and reliability. The transition to 0.5 mm pitch requires careful evaluation of the board design, solder paste selection, stencil design and component placement accuracy. At this pitch, ball and board pad diameters can be as small as 0.25 mm and 0.20 mm respectively. Drilled interstitial vias are no longer possible and higher ball count packages require micro-via board technology. The transition to CSP requires careful evaluation of these issues. Normal paste registration and BGA component tolerances can no longer achieve the required process levels and higher accuracy pick and place machines need to be implemented. This presentation will examine the optimization of these critical assembly operations, contrast the challenges at 0.5 mm and also look at the continuation of the process to incorporate smaller pitch flip chip devices.

  • PDF

Development of Hardware Simulator for Operation Analysis of DC Microgrid (DC 마이크로그리드의 동작분석을 위한 하드웨어 시뮬레이터 개발)

  • Lee, Ji-Heon;Kim, Won-Yong;Kim, Jong-Won;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.577-586
    • /
    • 2011
  • This paper describes the development of hardware simulator for the operation analysis of DC microgrid. The hardware simulator consists of several distributed power sources such as a wind power generation, solar power and fuel cell, and two energy storages such as a supercapacitor and battery. The main controller which performs a role of energy management and state monitoring is connected with the local controller in each power source and storage through ethernet-based communication link. The developed hardware simulator can be utilized to analyze the performance DC microgrid with practical manner.

Polarization Selective Blazed Grating Employing Metal-slit Arrays (금속 슬릿 배열로 구성된 편광 선택 가능한 블레이즈드 회절 격자)

  • Jung, Young Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.53-57
    • /
    • 2013
  • A polarization selective blazed grating employing metal-slit arrays was proposed. Nano-scale metal-slits were applied to the micro-scale blazed grating to give the functionality of polarization selection. Case study was carried out for the proposed structure utilizing numerical FDTD (Finite Difference Time Domain method) simulation. Diffraction efficiency of 77.61% and polarization extinction ratio of 8.99 was achieved with arbitrary parameters and diffraction efficiency of 64.22% and polarization extinction ratio of 81.09 was achieved with other parameters to enhance extinction ratio.

Autonomous Operation Analysis of DC Microgrid based on Droop Control (Droop 제어를 기반으로 한 직류 마이크로그리드의 자율 동작 분석)

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.342-350
    • /
    • 2011
  • This paper describes the autonomous operation analysis of DC microgrid based on droop control. In order to verify the whole system operation, detailed simulation models for wind power generation, solar power generation, and battery were developed with user-defined models programmed with C-code in PSCAD/ EMTDC software. The simulation results confirm that the DC microgrid with droop control make it feasible to provide power to the load with stable manner. Based on simulation results a prototype of DC microgrid was built and tested in the lab to verify the autonomous operation experimentally. The droop control scheme can suppress the circulating current, and offers each unit to be controlled autonomously without any communication link.

Modified droop control scheme for load sharing amongst inverters in a micro grid

  • Patel, Urvi N.;Gondalia, Dipakkumar;Patel, Hiren H.
    • Advances in Energy Research
    • /
    • v.3 no.2
    • /
    • pp.81-95
    • /
    • 2015
  • Microgrid, which can be considered as an integration of various dispersed resources (DRs), is characterized by number of DRs interfaced through the power electronics converters. The microgrid comprising these DRs is often operated in an islanded mode. To minimize the cost, reduce complexity and increase reliability, it is preferred to avoid any communication channel between them. Consequently, the droop control method is traditionally adopted to distribute active and reactive power among the DRs operating in parallel. However, the accuracy of distribution of active and reactive power among the DRs controlled by the conventional droop control approach is highly dependent on the value of line impedance, R/X i.e., resistance to reactance ratio of the line, voltage setting of inverters etc. The limitations of the conventional droop control approach are demonstrated and a modified droop control approach to reduce the effect of impedance mis-match and improve the time response is proposed. The error in reactive power sharing is minimized by inserting virtual impedance in line with the inverters to remove the mis-match in impedance. The improved time response is achieved by modifying the real-power frequency droop using arctan function. Simulations results are presented to validate the effectiveness of the control approach.