• 제목/요약/키워드: Micro Gap

검색결과 304건 처리시간 0.026초

Simulation of Low Temperature Plasmas for an Ultra Violet Light Source using Coplanar Micro Dielectric Barrier Discharges

  • Bae, Hyowon;Lee, Ho-Jun;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.138-144
    • /
    • 2016
  • The discharge characteristics of pulse-driven coplanar micro barrier discharges for an ultraviolet (UV) light source using Ne-Xe mixture have been investigated using a two-dimensional fluid simulation at near-atmospheric pressure. The densities of electrons, the radiative excited states, the metastable excited states, and the power loss are investigated with the variations of gas pressure and the gap distance. With a fixed gap distance, the number of the radiative states $Xe^*(^3P_1)$ increases with the increasing driving voltage, but this number shows weak dependency on the gas when that pressure is over 400 Torr. However, the number of the radiative states increases with the increase of the gap distance at a fixed voltage, while the power loss decreases. Therefore, a long gap discharge has higher efficiency for UV generation than does a short gap discharge. A slight change in the electrode tilt angle enhances the number of radiative species 2 or 3 times with the same operation conditions. Therefore, the intensity and efficiency of the UV light source can be controlled independently by changing the gap distance and the electrode structure.

Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study

  • Palone, Mario;Longo, Mattia;Arveda, Niki;Nacucchi, Michele;De Pascalis, Fabio;Spedicato, Giorgio Alfredo;Siciliani, Giuseppe;Lombardo, Luca
    • 대한치과교정학회지
    • /
    • 제51권2호
    • /
    • pp.135-141
    • /
    • 2021
  • Objective: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness. Methods: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (p < 0.05). Results: Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22. Conclusions: All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.

A Simple Plane-Shaped Micro Stator Using Silicon Substrate Mold and Enamel Coil

  • Choi, Ju Chan;Choi, Young Chan;Jung, Dong Geun;Lee, Jae Yun;Min, Seong Ki;Kong, Seong Ho
    • 센서학회지
    • /
    • 제22권5호
    • /
    • pp.333-337
    • /
    • 2013
  • This study proposes a simply fabricated micro stator for higher output power than previously reported micro stators. The stator has been fabricated by inserting enamel coil in silicon mold formed by micro etching process. The most merits of the proposed micro stator are the simple fabrication process and high output power. Previously reported micro stators have high resistance because the micro coil is fabricated by relatively thin-film-based deposition process such as sputtering and electroplating. In addition, the previously reported micro coil has many electrical contact points for forming the coil structure. These characteristics of the micro stator can lead to low performance in output power. However, the proposed micro stator adopts commercially available enamel coil without any contact point. Therefore, the enamel coil of the proposed micro stator has low junction resistance due to the good electrical quality compared with the deposited or electroplated metal coil. Power generation tests were performed and the fabricated stator can produce 5.4 mW in 4000 RPM, $1{\Omega}$ and 0.3 mm gap. The proposed micro stator can produce larger output power than the previously reported stator spite of low RPM and the larger gap between the permanent magnet and the stator.

Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography

  • Kim, Dong-Yeon;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.239-243
    • /
    • 2017
  • PURPOSE. The purpose of this study is to compare single and three-unit metal frameworks that are produced by micro-stereolithography. MATERIALS AND METHODS. Silicone impressions of a selected molar and a premolar were used to make master abutments that were scanned into a stereolithography file. The file was processed with computer aided design software to create single and three-unit designs from which resin frameworks were created using micro-stereolithography. These resin frameworks were subjected to investment, burnout, and casting to fabricate single and three-unit metal ones that were measured under a digital microscope by using the silicone replica technique. The measurements were verified by means of the Mann-Whitney U test (${\alpha}=.05$). RESULTS. The marginal gap was $101.9{\pm}53.4{\mu}m$ for SM group and $104.3{\pm}62.9{\mu}m$ for TUM group. The measurement of non-pontics in a single metal framework was $93.6{\pm}43.9{\mu}m$, and that of non-pontics in a three-unit metal framework was $64.9{\pm}46.5{\mu}m$. The dimension of pontics in a single metal framework was $110.2{\pm}61.4{\mu}m$, and that of pontics in a three-unit metal framework was $143.7{\pm}51.8{\mu}m$. CONCLUSION. The marginal gap was smaller for the single metal framework than for the three-unit one, which requires further improvement before it can be used for clinical purposes.

Fabrication of Micro-inductor and Capacior For RF MEMS Applications

  • Cho, Bek-Hee;Lee, Jae-Ho;Bae, Young-Ho;Cho, Chan-Sub;Lee, Jong-Hyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권2호
    • /
    • pp.102-110
    • /
    • 2002
  • In this paper, we present the fabrication of tunable capacitors and 3-dimensional inductors. This work was related to fabricated 3-dimensional device for need of micro device in developing new intelligence age. This device was fabricated by electroplating used electroplating PR and high-vacuum evaporation of metal. Fabricated micro-inductor is consisted of air-bridge on electroplating rod and electroplated core. Micro-capacitor is consisted of thin metal membrane and electroplated core. Electroplating material is used Cu metal solvent. Air-gap between metal-layers function as almost perfect isolation layer. The most advantage of our micro-inductor and micro-capacitor compared to present device is a possibility that can fabricate on RF MEMS(microelectro-mechanical systems) application with high performance and various function. In this paper, we present the fabrication of tunable capacitors and 3-dimensional inductors. This work was related to fabricated 3-dimensional device for need of micro-device in developing new intelligence age. This device was fabricated by electroplating used electroplating PR and high-vacuum evaporation of metal. Fabricated micro-inductor is consisted of air-bridge on electroplating rod and electroplated core. Micro-capacitor is consisted of thin metal membrane and electroplated core. Electroplating material is used Cu metal solvent. Air-gap between metal-layers function as almost perfect isolation layer. The most advantage of our micro-inductor and micro-capacitor compared to present device is a possibility that can fabricate on RF MEMS application with high performance and various functions.

AlN Based RF MEMS Tunable Capacitor with Air-Suspended Electrode with Two Stages

  • Cheon, Seong J.;Jang, Woo J.;Park, Hyeon S.;Yoon, Min K.;Park, Jae Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권1호
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, a MEMS tunable capacitor was successfully designed and fabricated using an aluminum nitride film and a gold suspended membrane with two air gap structure for commercial RF applications. Unlike conventional two-parallel-plate tunable capacitors, the proposed tunable capacitor consists of one air suspended top electrode and two fixed bottom electrodes. One fixed and the top movable electrodes form a variable capacitor, while the other one provides necessary electrostatic actuation. The fabricated tunable capacitor exhibited a capacitance tuning range of 375% at 2 GHz, exceeding the theoretical limit of conventional two-parallel-plate tunable capacitors. In case of the contact state, the maximal quality factor was approximately 25 at 1.5 GHz. The developed fabrication process is also compatible with the existing standard IC (integrated circuit) technology, which makes it suitable for on chip intelligent transceivers and radios.

Free Floating 구조를 갖는 마이크로 밸브의 제작 (A Fabrication of the Micro Valve with Free Floating Structure)

  • 손미영;문병필;전호승;한진우;김철주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.136-139
    • /
    • 2002
  • Previous valves have initial gap problem, high voltage or high pressure problem. In this paper, various micro valves with free floating structure have been fabricated and tested to solve the initial gap and high pressure problems. The paper presents how to etch Parylene-C which is a valve cap material without A1 mask layer. The maximum flow-rate of fabricated micro valve is$118{\mu\ell}$/min with $370{\mu}m$ orifice size and the leakage at the initial and reverse pressure is not observed.

  • PDF

인쇄전자를 위한 그라비아 옵셋 인쇄 (Gravure Offset Printing for Printed Electronics)

  • 김충환;최병오;류병순;김동수
    • 한국정밀공학회지
    • /
    • 제25권5호
    • /
    • pp.96-102
    • /
    • 2008
  • Manufacturing of printed electronics using printing technology has begun to get into the hot issue in many ways due to the low cost effectiveness to existing semi-conductor process. This technology, with low cost and high productivity, can make it possible to produce printed electronics such as TFT, solar cell, RFID Tag, printed battery, and so on. In this study, apparatus of gravure-offset printing are developed for fine line-width/gap printing and the results obtained from the apparatus shows that it is possible to make around 20 micro-meter line-width/gap printing patterns. The roll-to-roll printing system for fine line-width printing based on primary experiment is presented. The printing results obtained from the system shows around 30 micro-meter line-width/gap printing patterns.

미세 연소기 개발 (II) - 미세동력 장치용 미세 전극의 제작과 성능평가 - (Design and Development of Micro Combustor (II) - Design and Test of Micro Electric Spark discharge Device for Power MEMS -)

  • 권세진;이대훈;박대은;윤준보;한철희
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.524-530
    • /
    • 2002
  • Micro electric spark discharge device was fabricated on a FOTURAN glass wafer using MEMS processing technique and its performance of electron discharge and subsequent formation of ignition kernel were tested. Micro electric spark device is an essential subsystem of a power MEMS that has been under development in this laboratories. In a combustion chamber of sub millimeter scale depth, spark electrodes are formed by electroplating Ni on a base plate of FOTURAN glass wafer. Optimization of spark voltage and spark gap is crucial for stable ignition and endurance of the electrodes. Namely, wider spark gaps insures stable ignition but requires higher ignition voltage to overcome the spark barrier. Also, electron discharge across larger voltage tends to erode the electrodes limiting the endurance of the overall system. In the present study, the discharge characteristics of the proptotype ignition device was measured in terms of electric quantities such as voltage and currant with spark gap and end shape as parameters. Discharge voltage shows a little decrease in width of less than 50㎛ and increases with electrode gap size. Reliability test shows no severe damage over 10$\^$6/ times of discharge test resulting in satisfactory performance for application to proposed power MEMS devices.

Micro-CT를 이용한 발거된 유구치의 기성금속관 평가 (Micro-CT Evaluation of Stainless Steel Crowns on Extracted Primary Molars)

  • 정보람;신종현;정태성;김지연;김신
    • 대한소아치과학회지
    • /
    • 제42권1호
    • /
    • pp.53-61
    • /
    • 2015
  • 소아치과 임상에서 기성금속관 수복은 매우 높은 활용성과 사용빈도에도 불구하고 완벽하고 정밀한 수복이 쉽지 않은 항목으로 판단된다. 불량한 변연 적합, 변연부 치태 침착, 인접 영구치의 맹출 장애, 접착제 소실 및 이차 우식, 부적절한 지대치 삭제, 교합면 천공 등이 임상적으로 흔히 관찰되는 문제점들이다. 본 연구는 기성금속관이 장착된 상태로 발치된 유구치를 대상으로 수복 상태를 평가해 봄으로써, 빈번한 결함과 착오들을 찾아낼 목적으로 시도되었다. 부산대학교 치과병원 소아치과에서 발치된 기성금속관 수복 유구치 97개를 대상으로 육안적 평가와 micro-computed tomography(micro-CT) 영상을 분석하였다. 변연 적합도, 접착제 소실, 이차우식, 교모성 천공, 변연부 연마 결함, 선반(ledge) 형성 등의 항목으로 수복상태를 평가하여, 다음과 같은 결과를 얻었다. 조사항목들을 대상치아 기준으로 보았을 때, 접착제 소실이 가장 빈번하였으며(98%), 뒤를 이어 이차우식(42.3%), 변연부 연마 결함(41.2%), 선반(ledge) 형성(29.9%), 교모성 천공(17.5%)의 순으로 나타났다. 변연 간격이 클수록 접착제 소실이 증가하는 경향을 보였고, 접착재 소실은 변연 간격 및 이차 우식과 유의한 상관성을 보였다. 평균 변연간격은 $0.31{\pm}0.26mm$ 였으며, 상악 제2 유구치에서 가장 크게 나타났다. 변연이 백악법랑경계 상방에 위치하는 경우가 가장 많았고, 변연이 치관 상방에 위치할수록 변연 간격은 작게 나타났다(p < 0.05).