• 제목/요약/키워드: Micro Computed Tomography

검색결과 262건 처리시간 0.026초

Quantification of Microstructures in Mice Alveolar Bone using Micro-computed tomography (${\mu}CT$)

  • Park, Hae-Ryoung;Kim, Hyun-Jin;Park, Byung-Ju
    • International Journal of Oral Biology
    • /
    • 제38권3호
    • /
    • pp.87-92
    • /
    • 2013
  • Periodontal inflammation increases the risk of tooth loss, particularly in cases where there is an associated loss of alveolar bone and periodontal ligament (PDL). Histological and morphometric evaluation of periodontal inflammation is difficult. Especially, the lengths of the periodontal ligament and interdental alveolar bone space have not been quantified. A quantitative imaging procedure applicable to an animal model would be an important clinical study. The purpose of this study was to quantify the loss of alveolar bone and periodontal ligament by evaluation with micro-computed tomography (micro-CT). Another purpose was to investigate differences in infections with systemic E. coli LPS and TNF-${\alpha}$ on E. coli lipopolysaccharide (LPS) in loss of alveolar bone and periodontal ligament model on mice. This study showed that linear measurements of alveolar bone loss were represented with an increasing trend of the periodontal ligament length and interdental alveolar process space. The effects of systemic E. coli LPS and TNF-${\alpha}$ on an E. coli LPS-induced periodontitis mice model were investigated in this research. Loss of periodontal ligament and alveolar bone were evaluated by micro-computed tomography (micro-CT) and calculated by the two- and three dimensional microstructure morphometric parameters. Also, there was a significantly increasing trend of the interdental alveolar process space in E. coli LPS and TNF-${\alpha}$ on E. coli LPS compared to PBS. And E. coli LPS and TNF-${\alpha}$ on E. coli LPS had a slightly increasing trend of the periodontal ligament length. The increasing trend of TNF-${\alpha}$ on the LPS-induced mice model in this experiment supports the previous studies on the contribution of periodontal diseases in the pathogenesis of systemic diseases. Also, our findings offer a unique model for the study of the role of LPS-induced TNF-${\alpha}$ in systemic and chronic local inflammatory processes and inflammatory diseases. In this study, we performed rapidly quantification of the periodontal inflammatory processes and periodontal bone loss using micro-computed tomography (micro-CT) in mice.

Micro-computed tomographic evaluation of the effect of fluoride agents on white spot lesions: An in vitro study

  • Hong, Sook-Chan;Lee, Dong-Yul;Kim, Yae-Jin
    • 대한치과교정학회지
    • /
    • 제52권1호
    • /
    • pp.75-79
    • /
    • 2022
  • Objective: To investigate remineralizing effect of three fluoride regimens on artificially demineralized enamel around orthodontic bracket by analyzing mineral density (MD) acquired from micro-computed tomography (micro-CT). Methods: Forty-eight bracket bonded bovine incisors were prepared to create demineralized enamel (DE) surface. The samples were divided into four groups according to the fluoride regimen: 1) no fluoridation, 2) 1.23% acidulated phosphate fluoride (APF) gel, 3) fluoridated toothpaste, and 4) 0.05% sodium fluoride mouthwash. Micro-CT was scanned after demineralization (T0), and 2 weeks (T1) and 4 weeks (T2) of fluoridation. Results: APF gel showed highest remineralization of DE during T1-T0 interval among the groups (p < 0.05); followed by toothpaste, mouthwash and no fluoridation. APF gel and toothpaste demonstrated significant increase in MD after 4 weeks of application (p < 0.05). Conclusions: Remineralization effects of three fluoride regimens were depicted through micro-CT analysis, of which APF gel was most effective.

X-ray 단층촬영기법을 이용한 스트랜드보드의 내부공극구조에 관한 연구 (Internal Void Structure of Strandboard using X-ray Computed Tomography)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권6호
    • /
    • pp.13-22
    • /
    • 2008
  • 보드의 기계적 성질에 영향을 미치는 공극에 대하여 공극을 두가지로 분류하고 밀도에 따른 오에스비의 내부 공극구조의 특성에 대하여 살펴보고자 하였다. 스트랜드보드의 내부공극을 X-ray 단층촬영기로 측정하고 이미지분석 소프트웨어를 사용하여 밀도에 따른 공극의 분포와 공극의 함유량을 조사하였다. 측정 전에 보드의 밀도를 밀도측정기와 전건법으로 측정하였으며 이 두 방법에 의해 측정된 결과는 아주 높은 상관관계를 보여주었다. X-ray를 서로 다른 배율로 조사하여 획득한 이미지를 바탕으로 분석한 결과, 저해상도에서는 스트랜드간의 공극(macro-void)의 측정이 가능하나 스트랜드내의 미세공극(micro-void)은 이미지획득이 불가능하였다. 중해상도에서는 두가지 형태 모두의 이미지 획득이 가능하였고, 고해상도에서는 대부분의 미세공극 이미지의 획득이 가능하였다. 저배율을 채택하여 스트랜드간의 공극을 측정하고 스트랜드내의 미세공극은 관련식을 이용하여 추정하였다. 이를 통해 보드내부에 존재하는 스트랜드간의 공극분포를 파악할 수 있었으며 그 공극의 함유비율을 정확하게 산정할 수 있었다.

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Does mini-implant-supported rapid maxillary expansion cause less root resorption than traditional approaches? A micro-computed tomography study

  • Alcin, Rukiye;Malkoc, Siddik
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.241-249
    • /
    • 2021
  • Objective: This study aimed to evaluate the volume, amount, and localization of root resorption in the maxillary first premolars using micro-computed tomography (micro-CT) after expansion with four different rapid maxillary expansion (RME) appliances. Methods: In total, 20 patients who required RME and extraction of the maxillary first premolars were recruited for this study. The patients were divided into four groups according to the appliance used: mini-implant-supported hybrid RME appliance, hyrax RME appliance, acrylic-bonded RME appliance, and full-coverage RME appliance. The same activation protocol (one activation daily) was implemented in all groups. For each group, the left and right maxillary first premolars were scanned using micro-CT, and each root were divided into six regions. Resorption craters in the six regions were analyzed using special CTAn software for direct volumetric measurements. Data were statistically analyzed using Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test with Bonferroni adjustment. Results: The hybrid expansion appliance resulted in the lowest volume of root resorption and the smallest number of craters (p < 0.001). In terms of overall root resorption, no significant difference was found among the other groups (p > 0.05). Resorption was greater on the buccal surface than on the lingual surface in all groups except the hybrid appliance group (p < 0.05). Conclusions: The findings of this study suggest that all expansion appliances cause root resorption, with resorption craters generally concentrated on the buccal surface. However, the mini-implant-supported hybrid RME appliance causes lesser root resorption than do other conventional appliances.

Zoom-in Micro-tomography와 3차원 Fuzzy Distance Transform을 이용한 쥐 대퇴부의 해면골 두께 측정 (Trabecular bone Thickness Measurement of Rat Femurs using Zoom-in Micro-tomography and 3D Fuzzy Distance Transform)

  • 박정진;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.189-196
    • /
    • 2006
  • Micro computed tomography (micro-CT) has been used for in vivo animal study owing to its noninvasive and high spatial resolution capability. However, the sizes of existing detectors for micro-CT systems are too small to obtain whole-body images of a small animal object with $\sim$10 micron resolution and a part of its bones or other organs should be extracted. So, we have introduced the zoom-in micro-tomography technique which can obtain high-resolution images of a local region of an live animal object without extracting samples. In order to verify our zoom-in technique, we performed in vivo animal bone study. We prepared some SD (Sprague-Dawley) rats for making osteoporosis models. They were divided into control and ovariectomized groups. Again, the ovariectomized group is divided into two groups fed with normal food and with calcium-free food. And we took 3D tomographic images of their femurs with 20 micron resolution using our zoom-in tomography technique and observed the bone changes for 12 weeks. We selected ROI (region of interest) of a femur image and applied 2D FDT (fuzzy distance transform) to measure the trabecular bone thickness. The measured results showed obvious bone changes and big differences between control and ovariectomized groups. However, we found that the reliability of the measurement depended on the selection of ROI in a bone image for thickness calculation. So, we extended the method to 3D FDT technique. We selected 3D VOI (volume of interest) in the obtained 3D tomographic images and applied 3D FDT algorithm. The results showed that the 3D technique could give more accurate and reliable measurement.

영유아기 과잉치의 임상적 처치 및 micro-computed tomography 분석: 증례 보고 (Clinical Management and Micro-Computed Tomography Analysis of Supernumerary Teeth in Infancy: A Case Report)

  • 나채현;이한아;김한성;김지훈
    • 대한소아치과학회지
    • /
    • 제49권3호
    • /
    • pp.348-356
    • /
    • 2022
  • 과잉치는 치판의 과도한 성장과 분화에 의해서 발생된다. 이로 인해 이소맹출, 맹출지연, 인접치의 치근 흡수, 그리고 치간이개 등의 문제가 발생할 수 있다. 영유아기에서의 과잉치는 드물며 국내에서는 거의 보고되지 않았다. 이 증례에서는 3개의 매복된 과잉치가 있는 생후 2일된 신생아에 대해 보고하고 있으며, 환자는 21개월간 추적 관찰되었다. 유치열기에 맹출된 하나의 과잉치는 14개월이 되었을 때 중등도 진정 하에 발치되었다. 발치된 과잉치에 대해 micro-computed tomography (CT) 분석을 진행하여 치근단 부위의 미세한 형태 이상을 확인하였다. 과잉치 발치 후 치간이개는 감소하였고 구강위생도 개선되었다. 조기 진단 및 치료를 통해 과잉치로 인한 합병증을 예방할 수 있다.

Micro-computed tomography analysis of changes in the periodontal ligament and alveolar bone proper induced by occlusal hypofunction of rat molars

  • Shimizu, Yasuhiro;Hosomichi, Jun;Nakamura, Saeko;Ono, Takashi
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.263-267
    • /
    • 2014
  • Objective: To three-dimensionally elucidate the effects of occlusal hypofunction on the periodontal ligament and alveolar bone proper of rat molars by micro-computed tomography (micro-CT). Methods: Occlusal function in the molar area was restricted by attaching an anterior bite plate on the maxillary incisors and a metal cap on the mandibular incisors of 5-week-old male Wistar rats for 1 week. The periodontal ligament space and alveolar bone proper around roots of the mandibular first molar were assessed by histology and micro-CT. Results: The periodontal ligament space was narrower and the alveolar bone proper was sparser and less continuous in the hypofunction group than in the control group. Further, both the volume of the periodontal ligament and the volumetric ratio of the alveolar bone proper to the total tissue in the region of interest were significantly lower in the hypofunction group (p < 0.05). Conclusions: Occlusal hypofunction induces atrophic changes in the periodontal ligament and alveolar bone proper of rat molars.

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

CT를 이용한 알루미늄 반응고 성형품의 미세 결함 측정 (Measurements of Micro-Defects in the Aluminum Thixoformed Part using Computed Tomography(CT) Technology)

  • 이상용;김찬현
    • 소성∙가공
    • /
    • 제18권5호
    • /
    • pp.422-427
    • /
    • 2009
  • Computed tomography(CT) has been applied to measure micro-defects in the aluminum knuckle parts manufactured by the thixoforming process. 6061 aluminum alloys were used to form knuckle samples in the semi-solid temperature after the SIMA processing of billets. Tensile specimens were cut from the different locations in a thixoformed knuckle. The size and the distribution of forming defects in tensile specimens were analyzed using CT scanning and image analysis technology before tensile tests. It has been qualitatively shown that the stress-strain curves were significantly affected by the size and the distribution of forming defects although the defect sizes lie in the range of micro-meters.