• 제목/요약/키워드: Micro Chip

검색결과 530건 처리시간 0.031초

Microfluidic Biosensor System for HDL Cholesterol

  • Kim, Joo-Eun;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.717-720
    • /
    • 2003
  • A chromogenic biosensor employing microfluidics on a chip has been developed for the determination of high-density lipoprotein (HDL) cholesterol (HDL-C) in human serum. We have investigated a plain and effective method to immobilize enzymes within the microchip without chemically modifying micro-channel or technically micro-fabricating column reactor and fluid channel network. In assessing risk factors of coronary heart disease, a micro-chip system would minimize requirements of instrument and reagent handling.

  • PDF

DNA Chip 용 마이크로 핀에 관한 연구 (Manufacturing of Micro Dotting Pin)

  • 신홍규;이영수;남권선;김병희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.500-504
    • /
    • 2004
  • The bio-micro pin has been usually used for the biochemistry analysis. The manufacturing capability of the micro-pin and the their array with the effective and low-cost way is very important and it gives great economical benefits to developers. The micro-pin is composed of the sample channel for holding the liquid with the fixed volume, the flat tip which determines the printing quality and the pin head for preventing the rotation of the pin in the holder. In this study, we have manufactured newly designed micro-pins by the wire-EDM process with special jigs, and analyzed liquid holding and printing characteristics with respect to the variation of the shape and the tip size of the micro-pin.

  • PDF

Micro On-Off Valve 해석에 의한 최적 설계 (The optimal design by Micro On-Off Valve analysis)

  • 김동수;박상운;고창섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.285-290
    • /
    • 2005
  • Micro On-Off valves are currently recognized as the core technology in the fields of the micro fluid chip fur medical applications and production lines of semi-conduct chip. Micro valves that operate by compressed air need the high-speed responsibility, repeatability, the absorbability and the uniform pressure by the poppet. In this study, Micro On-Off valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

고밀도 프로빙 테스트를 위한 수직형 프로브카드의 제작 및 특성분석 (Development and Characterization of Vertical Type Probe Card for High Density Probing Test)

  • 민철홍;김태선
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.825-831
    • /
    • 2006
  • As an increase of chip complexity and level of chip integration, chip input/output (I/O) pad pitches are also drastically reduced. With arrival of high complexity SoC (System on Chip) and SiP (System in Package) products, conventional horizontal type probe card showed its limitation on probing density for wafer level test. To enhance probing density, we proposed new vertical type probe card that has the $70{\mu}m$ probe needle with tungsten wire in $80{\mu}m$ micro-drilled hole in ceramic board. To minimize alignment error, micro-drilling conditions are optimized and epoxy-hardening conditions are also optimized to minimize planarity changes. To apply wafer level test for target devices (T5365 256M SDRAM), designed probe card was characterized by probe needle tension for test, contact resistance measurement, leakage current measurement and the planarity test. Compare to conventional probe card with minimum pitch of $50{\sim}125{\mu}m\;and\;2\;{\Omega}$ of average contact resistance, designed probe card showed only $22{\mu}$ of minimum pitch and $1.5{\Omega}$ of average contact resistance. And also, with the nature of vertical probing style, it showed comparably small contact scratch and it can be applied to bumping type chip test.

마이크로 채널 내부 유동의 Micro-PIV측정과 제반 문제점 (Micro- PIV Measurements of Microchannel Flows and Related Problems)

  • 이상준;김국배
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 마이크로/바이오 가시화기술부문 학술강연회
    • /
    • pp.79-84
    • /
    • 2002
  • Most microfluidic devices such as heat sinks for cooling micro-chips, DNA chip, Lab-On-Chip, and micro pumps etc. have microchannels of various size. Therefore, the design of practical microfluidics demands detail information on flow structure inside the microchannels. However, detail velocity field measurements are rare and difficult to carry out. In addition, as the microfluidics expands, accurate understanding of microscale transport phenomena becomes very important. In this research, micro-PIV system was employed to measure the velocity fields of flow inside a micro-channel. We carried out PIV measurements for several microchannels with varying channels width, inlet and outlet shape, filters, CCD camera and ICCD camera, etc. For effective composition of micro-PIV system, first of all, it is essential to understand optics related with micro-imaging of particles and the particle dynamics encountered in micro-scale channel flows. In addition, it is necessary to find the optimal condition for given experimental environment and? micro-scale flow to be investigated. The problems encountered in measuring velocity field of micro-channel flows are discussed in this paper.

  • PDF

크기효과가 고려된 미소절삭시의 온도 및 응력특성에 관한 유한요소해석 (A Finite Element Analysis for the Characteristics of Temperature and Stress in Micro-machining Considering the Size Effect)

  • 김국원;이우영
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.128-139
    • /
    • 1998
  • In this paper, a finite element method for predicting the temperature and stress distributions in micro-machining is presented. The work material is oxygen-free-high-conductivity copper(OFHC copper) and its flow stress is taken as a function of strain, strain rate and temperature in order to reflect realistic behavior in machining process. From the simulation, a lot of information on the micro-machining process can be obtained; cutting force, cutting temperature, chip shape, distributions of temperature and stress, etc. The calculated cutting force was found to agree with the experiment result with the consideration of friction characteristics on chip-tool contact region. Because of considering the tool edge radius, this cutting model using the finite element method can analyze the micro-machining with the very small depth of cut, almost the same size of tool edge radius, and can observe the 'size effect' characteristic. Also the effects of temperature and friction on micro-machining were investigated.

  • PDF

마이크로 스프링 구조를 갖는 121 pins/mm2 고밀도 프로브 카드 제작기술 (Development of 121 pins/mm2 High Density Probe Card using Micro-spring Architecture)

  • 민철홍;김태선
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.749-755
    • /
    • 2007
  • Recently, novel MEMS probe cards can support reliable wafer level chip test with high density probing capacity. However, manufacturing cost and process complexity are crucial weak points for low cost mass production. To overcome these limitations, we have developed micro spring structured MEMS probe card. For fabrication of micro spring module, a wire bonder and electrolytic polished gold wires are used. In this case, stringent tension force control is essential to guarantee the low level contact resistance of micro spring for reliable probing performance. For this, relation between tension force of fabricated probe card and contact resistance is characterized. Compare to conventional probe cards, developed MEMS probe card requires fewer fabrication steps and it can be manufactured with lower cost than other MEMS probe cards. Also, due to the small contact scratch patterns, we expect that it can be applied to bumping types chip test which require higher probing density.

시설원예에 있어서 물관리 지동화 시스템 개발 (Development of an Automatic Irrigation Control System in Protected Horticulture)

  • 김경수;이기명;장익주
    • 생물환경조절학회지
    • /
    • 제1권1호
    • /
    • pp.61-71
    • /
    • 1992
  • This study is performed to develop an automatic irrigation control of system for effective water management in greenhouse. The automatic irrigation control system is composed of an IR-RED optical sensor in tensiometer and an One-chip micro controller. The following results are obtained : 1. A practical IR-RED optical sensor in tensiometer, which shows the starting point of irrigation, was developed. 2. The automatic irrigation system with the optical sensor and One-chip micro controller was developed and also designed to be able to combine with the control system for temperature, curtain opening, etc. 3. A multiple irrigation control system for several greenhouses were suggested. 4. The results of the system test with the driving program for automatic water management were excellent.

  • PDF

Micro spiral inductor를 이용한 2.5Gb/s급 2:1 Multiplexer 설계 (A 2.5Gb/s 2:1 Multiplexer Design Using Inductive Peaking in $0.18{\mu}m$ CMOS Technology)

  • 김선중;최정명;범진욱
    • 대한전자공학회논문지SD
    • /
    • 제44권8호
    • /
    • pp.22-29
    • /
    • 2007
  • [ $0.18{\mu}m$ ] CMOS공정을 이용하여 supply voltage 1.8V에서 2.5Gb/s 이상의 데이터 처리속도를 가지는 2:1 Multiplexer(MUX) 설계를 하였다. High speed 동작을 위한 주파수의 한계를 극복하기 위해서 4.7 nH의 on-chip micro spiral micro inductor $(20\times20{\mu}m2)$가 설계 되었고, 10개 이상의 inductor를 사용하고도 칩 면적 증가가 거의 없으면서 inductive peaking 효과를 극대화할 수 있었다. 칩 측정은 on-wafer로 진행되었고, micro spiral inductor가 있는 2:1 MUX와 그것이 없는 2:1 MUX 각각 측정하여 그 결과를 비교하였다. 측정결과 micro spiral inductor를 가진 2:1MUX가 rise time과 fall time이 1.25Gb/s에서는 rise time이 23%, fall time은 3%의 peaking 개선 효과가 있는 것을 확인하였다. 2.5Gb/s에서는 fall time이 약 5.3%, rise time 3.5%의 개선 효과를 보았다. 전체 소비전력은 61.2mW, 2.5Gb/s에서 voltage output swing은 $180mV_{p-p}$로 측정되었다.

Characterization of Nanopores on Micropillars Pt Electrodes for Non-Enzymatic Electrochemical Sensor Applications

  • Park, Dae-Joon;Lee, Yi-Jae;Park, Jae-Yeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.161-165
    • /
    • 2007
  • In this paper, mesoporous Pt on micro pillars Pt electrode is newly designed, fabricated, and characterized on silicon substrate for non-enzymatic electrochemical sensor micro-chip integrated with CMOS readout circuitry. The fabricated micro/nano Pt electrode has cylindrical hexangular arrayed nano Pt pores with a diameter of 3.2 nm which is formed on top of the micro pillars Pt electrode with approximately $6{\mu}m$ in diameter, $6{\mu}m$ in space, and $50{\mu}m$ in height. The measured current responses of the fabricated plane Pt, mesoporous Pt, and mesoporous Pt on the micro pillar Pt electrodes are approximately $9.9nA/mm^2,\;6.72{\mu}A/mm^2,\;and\;7.67{\mu}A/mm^2$ in 10mM glucose solution with 0.1M phosphate buffered saline (PBS) solution, respectively. In addition, the measured current responses of the fabricated plane Pt, mesoporous Pt, and mesoporous Pt on the micro pillar Pt electrodes are approximately $0.15{\mu}A/mm^2,\;0.56{\mu}A/mm^2,\;and\;0.74{\mu}A/mm^2$ in 0.1mM ascorbic acid (AA) solution with 0.1M phosphate buffered saline (PBS) solution, respectively. This experimental results show that the proposed micro/nano Pt electrode is highly sensitive and promising for CMOS integrated non-enzymatic electrochemical sensor applications. Since the micro-pillar Pt electrode can also be utilized with a micro-fluidic mixer in the sensor chip, the sensor chip can be much smaller, cheaper, and easier to be fabricated.