• 제목/요약/키워드: Micro Chamber

검색결과 242건 처리시간 0.041초

실험실규모 순환유동층에서 RDF와 RPF의 연소 특성에 관한 연구 (Combustion of RDF and RPF in a Lab-Scale Circulating Fluidized Bed)

  • 이재성;이응록;안민하;박상욱;신동훈;황정호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.173-179
    • /
    • 2004
  • Combustion of refuse derived fuel(RDF) and refuse plastic fuel (RPF) was carried out in a lab-scale circulating fluidized bed. Experiment was investigated cold flow visualization. RDF was made by C & tech and RPF was made by KRS. The results include distribution of temperature in the combustion chamber, and concentrations of flue gas such as $O_2$, $CO_2$, CO, $NO_x$ and HCs Micro G.C(gas chromatograph) was employed to find out concentration of He Temperature distribution was different when RDF and RPF were burnt respectably. As air ratio became increased, $CO_2$, CO, and total of HCs emissions were decreased. According to the number of carbon atom of HCs, HC were classified as five kinds of HC.

  • PDF

Alteration in Erythrocyte Deformability in Diabetes Mellitus

  • Shin, Se-Hyun;Singh, Megha
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권1호
    • /
    • pp.17-26
    • /
    • 2006
  • Diabetes mellitus (DM) is a metabolic disorder, characterized by varying or persistent hyperglycemia, which induces several changes in the erythrocyte membrane and its cytoplasm, leading to alteration in the deformability. Techniques applied to measure this are based on filtration of erythrocyte suspension through a membrane and to obtain diffraction pattern under sheared conditions. Ektacytometry requiring less quantity of blood with disposable flow chamber used to measure the deformability of erythrocytes obtained from patients with diabetes and also associated with nephropathy and retinopathy. A decreasing trend of deformability in these patients is observed. The shape parameter form factor, as determined by image processing procedure, increases with the increased of blood glucose levels and shows a pattern similar to filtration time of erythrocyte suspensions through cellulose membranes. Further work is suggested to detect micro-level changes in cell membrane in diabetic patients

  • PDF

보급형 He-Ne 타원해석기의 제작과 $TiO_2$ 박막 유효밀도 변화의 in-situ 측정 (Fabrication of He-Ne ellipsometer and in-situ measurement of effective density variation of $TiO_2$thin films)

  • 김상준;방현용;김상열
    • 한국진공학회지
    • /
    • 제8권4A호
    • /
    • pp.432-437
    • /
    • 1999
  • We have fabricated an in situ ellipsometer operating at He-Ne wavelength. It can be applied to the real-time, in-situ tracking of the ellisometric change which occurs during various sample treatments. As a rotating analyzer type, all optical elements and related parts are designed to share a common hollow-axis configuration, and hence the ellipsometer is compact in shape and simple in design. It is mountable on the spare ports of vacuum chamber with ease. Using this ellipsometer, we observed the effective density variation of previously grown $TiO_2$ thin films by using electron beam evaporation. The packing density of the as-grown film was 82%. When exposed to atomsphere, the micro-void of the film was filled with water vapor. This water-filled $TiO_2$ thin film was subject to heating/cooling cycles in vacuum and the ellipsometric variation versus temperature and cycling number was measured in real time using this in situ He-Ne ellipsometer.

  • PDF

A Study on the Passive Microvalve Applicable to Drainage Device for Glaucoma

  • Sim, Tae-Seok;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.253-258
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves, which are applicable to glaucoma implants. The proposed microvalves were designed using fluidic theory. The microvalves consisted of microchannels and chambers. The microchannels had a constant fluidic resistance generating a pressure difference. Six kinds of microvalves were designed using fluidic equations for laminar flow and fabricated to examine the influences of chamber size, channel length and the shape of channel cross section. The pressure difference between the designed microvalve and the fabricated microvalve was measured to be less than 4%.

뇌정위적 방사전수술을 위한 소조사면 측정 (Small Field Dosimetry for Stereotacitc Radiosurgery)

  • 최동락;안용찬;이정일;허승재
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.59-64
    • /
    • 1995
  • 본 연구의 목적은 뇌정위적 방사선수술을 시행하기 위한 치료계획 수립에 필요한 빔 측정자료를 구하는 것이다. 다이오우드, 필름, 미소전리함 (0.003cc), TL, 그리고 물팬톰용 전리함 (0.125 cc)을 이용하여 빔 자료를 측정하였다. 측정된 결과는 상호비교하였으며 OAR 은 필름, 산란인자와 TMR은 다이오우드로 측정된 자료를 치료계획용 컴퓨터의 기본자료로 사용하였다.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

마이크로패턴된 전극을 이용한 실시간 생체물질 감지 랩칩 시스템 (Interdigitated Microelectrode Lab-on-a-chip sensing system for Biomoelcule Detection)

  • 유용경;황교선;이정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1223-1224
    • /
    • 2015
  • Recently, Alzheimer's Disease (AD) is one of the biggest threats to healthy society. Current medical AD diagnosis depends on interviews and the molecular neuroimaging. There is no cure for the disease, which worsens as it progresses, and eventually leads to death. Amyloid ${\beta}$ and Tau-meditated neuronal injury and dysfunction are candidates of biomarker for AD diagnosis using blood. For highly sensitive and selective biosensor platform, interdigitated microelectrodes (IMEs) sensor was prepared with micro fabrication process and Amyloid ${\beta}$ antibody. Amyloid ${\beta}$ concentration of 1, 10, 100, and 1000 pg/mL was injected in reaction chamber with IME sensors, impedance and conductance of IMEs changed respectively. These results show our newly proposed IMEs sensor can be usefully utilized for AD early diagnosis.

  • PDF

Fatigue Test of MEMS Device: a Monolithic Inkjet Print

  • Park, Jun-Hyub;Oh, Yong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.798-807
    • /
    • 2004
  • A testing system was developed to improve the reliability of printhead and several printheads were tested. We developed a thermally driven monolithic inkjet printhead comprising dome-shaped ink chambers, thin film nozzle guides, and omega-shaped heaters integrated on the top surface of each chamber. To perform a fatigue test of an inkjet printhead, the testing system automatically detects a heating failure using a Wheatstone bridge circuit. Various models were designed and tested to develop a more reliable printhead. Two design parameters of the width of reinforcing layer and heater were investigated in the test. Specially., the reinforcing layer was introduced to improve the fatigue life of printhead. The life-span of heater with a reinforcing layer was longer than that without a reinforcing layer. The wider the heater was, the longer the life of printhead was.

물혼합 연료 및 EGR의 조합에 의한 디젤기관의 질소산화물과 매연미립자 동시저감 기술에 관한 연구 (Technology for Reducing NOx and Soot Particulate using EGR with Water Emulsified Fuel in Diesel Engines)

  • 박권하;박태인;김기형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.356-363
    • /
    • 1997
  • Many research works have been carried out to investigate the factors governing the performance of diesel engine. The area of the study has been focused on reducing both of NOx and smoke because of many difficulties to reduce them simultaneously in diesel engines. One of the efforts is an application of EGR technology to reduce NOx emission, which is very effective, but increases other emissions and makes fuel economy worse. In order to solve the problem, EGR is employed with water emulsified fuel and tested in this paper. Emulsified fuel is produced by centrifugal mixer and the amount of water is controlled by water injector and pulse generator, and EGR rate is controlled with 6-step control valve. The chamber pressure, fuel consumption and emissions are measured with various values of both EGR and water mixing rate, The results show that NOx emission is reduced much rather and smoke is also reduced simultaneously.

  • PDF

이동식 복지용구 소독장치를 위한 제어시스템 개발 (Development of Control System for Disinfection Unit of Moving Welfare Device)

  • 성충일;조성범;황기현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.304-306
    • /
    • 2012
  • 본 논문은 복지용구를 소독하는데 필요한 제어시스템을 개발하였다. 본 연구에서 개발한 제어시스템은 과산화수소 증기를 이용한 살균하는 제어회로, 저진공을 이용한 살균하는 챔버 제어회로, 마이크로버블을 이용한 세탁 시스템 제어회로를 개발하였다.

  • PDF