• Title/Summary/Keyword: Method of Response Limitation

Search Result 126, Processing Time 0.024 seconds

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Satisfaction Survey on Video Lectures using the Metaversity App (메타버시티 앱을 이용한 동영상 강의 만족도 조사)

  • Jeongkyu Park;Byeongkyou Jeon;KyeongHwan Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.101-108
    • /
    • 2024
  • Recently, Metaverse technology has emerged as an important topic in various fields. Metaverse refers to a three-dimensional virtual space in which social and economic activities similar to the real world are possible. Among the 235 third-year students who applied the Metaversity app in the radiology department of this university from September to December 2023, 200 participated in a survey to determine the difference in student response and satisfaction when applying the Metaversity app. analyzed. First, the most satisfactory VOD viewing method was viewing through the Metaversity app, followed by viewing through the LMS. Second, 'I think online videos are appropriate for holiday reinforcement.' showed the highest score at 4.35±0.60, 'I want face-to-face classes and online classes to be held simultaneously.' was 4.25±0.87, and 'I think meta. 'I watched it well through the Metaversity app' was the lowest at 4.10±0.30, and 'VOD viewing through the Metaversity app was used appropriately in class' was the lowest at 3.99±0.75. Also, there was no significant difference in the response to the teaching method (p>0.05). Third, in terms of satisfaction with VOD viewing using the Metaversity app, 'Applying the Metaversity app was interesting and fun' ranked the highest at 4.24±0.88. The score was high, with 'Better improvement is needed to actively utilize the metaversity app' at 4.00±0.45, and 'I hope the metaversity app is implemented in other remote classes' at 3.77±0.88. appear. 'VOD classes through the Metaversity app are better than the existing LMS method.' was found to be 3.44±0.66. Additionally, there was no significant difference in satisfaction with classes according to age and gender (p>0.05). The correlation between response and satisfaction with the metaversity app is 0.601, which can be considered very significant (p>0.001). As a limitation of this study, although we surveyed students' satisfaction with using the Metaversity app, we were unable to investigate the satisfaction of instructors who interact with students. In the future, we did not consider the instructor's satisfaction in classes using the Metaversity app. Research must be conducted, and universities must have institutional support and continued interest until metaversity apps are selected and used to prepare for distance learning.

The detection of collapsible airways contributing to airflow limitation (기류 제한에 영향을 미치는 허탈성 기도의 분석)

  • Kim, Yun Seong;Park, Byung Gyu;Lee, Kyong In;Son, Seok Man;Lee, Hyo Jin;Lee, Min Ki;Son, Choon Hee;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.558-570
    • /
    • 1996
  • Background : The detection of Collapsible airways has important therapeutic implications in chronic airway disease and bronchial asthma. The distinction of a purely collapsible airways disease from that of asthma is important because the treatment of the dormer may include the use of pursed lip breathing or nasal positive pressure ventilation whereas in the latter, pharmacologic approaches are used. One form of irreversible airflow limitation is collapsible airways, which has been shown to be a Component of asthma or to emphysema, it can be assessed by the volume difference between what exits the lung as determined by a spirometer and the volume compressed as measured by the plethysmography. Method : To investigate whether volume difference between slow and forced vital Capacity(SVC-FVC) by spirometry may be used as a surrogate index of airway collapse, we examined pulmonary function parameters before and after bronchodilator agent inhalation by spirometry and body plethysmography in 20 cases of patients with evidence of airflow limitation(chronic obstructive pulmonary disease 12 cases, stable bronchial asthma 7 cases, combined chronic obstructive pulmonary disease with asthma 1 case) and 20 cases of normal subjects without evidence of airflow limitation referred to the Pusan National University Hospital pulmonary function laboratory from January 1995 to July 1995 prospectively. Results : 1) Average and standard deviation of age, height, weight of patients with airflow limitation was $58.3{\pm}7.24$(yr), $166{\pm}8.0$(cm), $59.0{\pm}9.9$(kg) and those of normal subjects was $56.3{\pm}12.47$(yr), $165.9{\pm}6.9$(cm), $64.4{\pm}10.4$(kg), respectively. The differences of physical characteristics of both group were not significant statistically and male to female ratio was 14:6 in both groups. 2) The difference between slow vital capacity and forced vital capacity was $395{\pm}317ml$ in patients group and $154{\pm}176ml$ in normal group and there was statistically significance between two groups(p<0.05). Sensitivity and specificity were most higher when the cut-off value was 208ml. 3) After bronchodilator inhalation, reversible airway obstructions were shown in 16 cases of patients group, 7 cases of control group(p<0.05) by spirometry or body plethysmography d the differences of slow vital capacity and forced vital capacity in bronchodilator response group and nonresponse group were $300.4{\pm}306ml$, $144.7{\pm}180ml$ and this difference was statistically significant. 4) The difference between slow vital capacity and forced vital capacity before bronchodilator inhalation was correlated with airway resistance before bronchodilator(r=0.307 p=0.05), and the difference between slow vital capacity and forced vital capacity after bronchodilator was correlated with difference between slow vital capacity and forced vital capacity(r=0.559 p=0.0002), thoracic gas volume(r=0.488 p=0.002) before bronchodilator and airway resistance(r=0.583 p=0.0001), thoracic gas volume(r=0.375 p=0.0170) after bronchodilator, respectively. 5) The difference between slow vital capacity and forced vital capacity in smokers and nonsmokers was $257.5{\pm}303ml$, $277.5{\pm}276ml$, respectively and this difference did not reach statistical significance(p>0.05). Conclusion : The difference between slow vital capacity and forced vital capacity by spirometry may be useful for the detection of collapsible airway and may help decision making of therapeutic plans.

  • PDF

PULSE OXIMETER AS A DIAGNOSTIC TEST OF PULP VITALITY (Pulse Oximeter를 이용한 치수생활력측정)

  • Koo, Bon-Kyung;Lee, Jae-Ho;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2000
  • Traditionally, EPT and thermal tests were used as diagnostic methods for pulp vitality test. The thermal and electrical stimulation tests are the methods to determine the vitality of a tooth based on its neuronal response. These have certain limitations, one of them is the difficulty of approaching the correct result in case of treatment of children. The reason is management problem caused by the unpleasant stimulation. Also, the response from patients are not objective, and false positive or false negative could be happened. Recently, laser doppler flowmetry and pulse oximeter which evaluate vascular integrity are introduced in an effort of overcoming to limitation of traditional methods. The principle of pulse oximeter is to and out level of oxygen saturation by ratio of the two pulses between emitted light and detected light penetrating them to the termination of body, such as ears or fingers. From this point of view, it can be applied to a tooth to determine its vitality. The objective of this study lies mainly on varifying pulse oximeter as a method of determining tooth vitality and providing basic data of its clinical implementation. The result of the research showed that level of oxygen saturation in vital teeth was average of 96.3% and 0.0% in pulpless teeth. As a comprehensive result, pulse oximeter could be an useful diagnostic equipment in determining of tooth vitality.

  • PDF

A Study on the Difference of Response Characteristics according to Description and Expression Method of Procedures (절차서의 기술 및 표현 방법에 따른 작업자 반응특성 차이 연구)

  • Jang, Tong Il;Lee, Yonghee;Oh, Yeon Ju;Lee, Yong Hee
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.117-124
    • /
    • 2013
  • Emergency operating procedures(EOPs) of nuclear power plants should be described considering the cognitive capability and limitation of operators and provide appropriate information in the aspect of human factors. Procedures which doesn't consider cognitive characteristics of operators can become causes of human errors. In previous researches, in order to reduce these problems related to the description of EOP, an improvement suggestion for EOP writer's guide has been proposed, which is reflected human factors aspects that should be considered when describing EOPs. The proposed items, however, have a necessity to be validated because it was listed from various documents such as standards and guidelines without any special validation process. For that reason, in this study, a validation process were performed to show that procedures, which are described in compliance with the requirement items proposed in the improved EOP writer's guide, have positive effects in the aspects of human errors and performance comparing with previous procedures. Experiments were performed to compare the performances of two tasks which are described in compliance with each writer's guide of before and after the improvement During each task was performed in experiments, changes of physiological responses such as EEG and ECG were measured to evaluate the cognitive workload and the stress of operators in each task. And also, as the performance, frequencies of errors and cognition speeds of each task were evaluated. In the results of the experiment, the portions of the ${\beta}$ wave decreased in the tasks overall after the improvement. In the case of ECG, change rates of the mean of R-R interval were decreased in the tasks after improvement. In the results of the performance, the cognition and the response time of the tasks after the improvement were predominant with statistical significancies. Error times in the tasks after improvement were decreased or same to the tasks before improvement. Conclusively, it was validated that the procedures were described in compliance with the improved EOP writer's guide had effects on the reduction of human errors and improvement of performance.

Study of the Respiratory Monitoring System by Using the MEMS Acceleration Sensor (MEMS 가속도 센서를 이용한 환자 호흡동작 모니터링 체계 연구)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Kim, Dong Wook;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • In this study, we developed and evaluated the patient respiration training method which can help to avoid the problems for the limitation of RGRT applicable patient cases. By using the MEMS (micro-electro-mechanical-system) acceleration sensor, we measured movement of motion phantom. We had compared the response of MEMS with commercially introduced real time patient monitoring (RPM) system. We measured the response of the MEMS with 1 dimensional motion phantom movement for 2.5, 3.0, 3.5 second of period and the 2.0, 3.0, 4.0 cm of the amplitudes. The measured period error of the MEMS system was 0.6~6.0% compared with measured period using RPM system. We found that the shape of MEMS signals were similar with RPM system. From this study, we found the possibility of MEMS as patient training system.

Design and Implementation of an In-Memory File System Cache with Selective Compression (대용량 파일시스템을 위한 선택적 압축을 지원하는 인-메모리 캐시의 설계와 구현)

  • Choe, Hyeongwon;Seo, Euiseong
    • Journal of KIISE
    • /
    • v.44 no.7
    • /
    • pp.658-667
    • /
    • 2017
  • The demand for large-scale storage systems has continued to grow due to the emergence of multimedia, social-network, and big-data services. In order to improve the response time and reduce the load of such large-scale storage systems, DRAM-based in-memory cache systems are becoming popular. However, the high cost of DRAM severely restricts their capacity. While the method of compressing cache entries has been proposed to deal with the capacity limitation issue, compression and decompression, which are technically difficult to parallelize, induce significant processing overhead and in turn retard the response time. A selective compression scheme is proposed in this paper for in-memory file system caches that rapidly estimates the compression ratio of incoming cache entries with their Shannon entropies and compresses cache entries with low compression ratio. In addition, a description is provided of the design and implementation of an in-kernel in-memory file system cache with the proposed selective compression scheme. The evaluation showed that the proposed scheme reduced the execution time of benchmarks by approximately 18% in comparison to the conventional non-compressing in-memory cache scheme. It also provided a cache hit ratio similar to the all-compressing counterpart and reduced 7.5% of the execution time by reducing the compression overhead. In addition, it was shown that the selective compression scheme can reduce the CPU time used for compression by 28% compared to the case of the all-compressing scheme.

A Study on Issues and Improvements Plan for National Safety Assessment (국가안전대진단의 문제점과 개선방안)

  • Shin, Jae-Hun;Kim, Sang-Woon
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.334-342
    • /
    • 2018
  • Purpose: The purpose of this study is to examine and improve the issues related to National Safety Inspection currently operation and reform the system for response to various disasters. Method: For the completion, this study established theoretical background using materials related to National Safety Inspection and identified the issues using the open statistical data for National Safety Inspection to suggest the improvement plans. Results: National Safety Inspection has been operating a complete large-scale inspection on risk factors in cooperation with the central government, local governments, and citizens since 2015 to remove various disaster factors neglected in people's daily lives. Operation of National Safety Inspection had positive influence in preventing major disasters. However, inefficient activity is pointed out due to issues related to cooperation with other institutes, limitation for citizen's positional role, and superficial inspection. Conclution: To solve this issue, this study proposed strengthening of communication activity with disaster institutes, strengthening of efficiency through citizen participation by type, and actualization of checklist used in National Safety Inspection.

The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response (3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구)

  • Park, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.117-122
    • /
    • 2018
  • A large-capacity three-phase system air conditioner recently includes an inverter circuit to reduce power consumption. The inverter circuit uses a DC voltage that comes from DC-link power capacitor with the function of rectifying, which means AC voltage to DC voltage using a diode. An electrolytic capacitor is generally used to satisfy the voltage ripple and current ripple conditions of a DC-link power capacitor used for rectifying. Reducing the capacitance of the capacitor decreases the size, weight, and cost of the circuit. This paper proposes an algorithm to reduce the input ripple current by combining the minimum point estimation phase locked loop (PLL) phase control and the average voltage d axis current control technique. When this algorithm was used, the input ripple current decreased by almost 90%. The current ripple of the DC-link capacitor decreased due to the decrease in input ripple current. The capacitor capacity can be reduced but the electrolytic capacitor has a heat generation problem and life-time limitations because of its large equivalent series resistance (ESR). This paper proposes a method to select a film capacitor considering the current ripple at DC-link stage instead of an electrolytic capacitor. The capacitance was selected considering the voltage limitation, RMS (Root Mean Square) current capacity, and RMS current frequency analysis. A $1680{\mu}F$ electrolytic capacitor can be reduced to a $20{\mu}F$ film capacitor, which has the benefit of size, weight and cost. These results were verified by motor operation.

Towards high-accuracy data modelling, uncertainty quantification and correlation analysis for SHM measurements during typhoon events using an improved most likely heteroscedastic Gaussian process

  • Qi-Ang Wang;Hao-Bo Wang;Zhan-Guo Ma;Yi-Qing Ni;Zhi-Jun Liu;Jian Jiang;Rui Sun;Hao-Wei Zhu
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.267-279
    • /
    • 2023
  • Data modelling and interpretation for structural health monitoring (SHM) field data are critical for evaluating structural performance and quantifying the vulnerability of infrastructure systems. In order to improve the data modelling accuracy, and extend the application range from data regression analysis to out-of-sample forecasting analysis, an improved most likely heteroscedastic Gaussian process (iMLHGP) methodology is proposed in this study by the incorporation of the outof-sample forecasting algorithm. The proposed iMLHGP method overcomes this limitation of constant variance of Gaussian process (GP), and can be used for estimating non-stationary typhoon-induced response statistics with high volatility. The first attempt at performing data regression and forecasting analysis on structural responses using the proposed iMLHGP method has been presented by applying it to real-world filed SHM data from an instrumented cable-stay bridge during typhoon events. Uncertainty quantification and correlation analysis were also carried out to investigate the influence of typhoons on bridge strain data. Results show that the iMLHGP method has high accuracy in both regression and out-of-sample forecasting. The iMLHGP framework takes both data heteroscedasticity and accurate analytical processing of noise variance (replace with a point estimation on the most likely value) into account to avoid the intensive computational effort. According to uncertainty quantification and correlation analysis results, the uncertainties of strain measurements are affected by both traffic and wind speed. The overall change of bridge strain is affected by temperature, and the local fluctuation is greatly affected by wind speed in typhoon conditions.