A Study on the Development Plan of Situation-Aware Service Based on the Characteristics Analysis of Smartphone (스마트폰의 현황 분석을 통한 상황인식서비스의 발전방향 제시)

  • Lee, Hyun-Jik;Koo, Dae-Sung;Park, Chan-Ho;Lee, Jung-Bin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.303-309
    • /
    • 2011
  • Situation awareness services which increasingly expand their influence in everyday life can be classified into location-based service and social network service. Their quality of service (QoS) can be differed based on the location accuracy of smart phones and accuracy of directional recognition technology. This study was conducted to analyze GPS, digital compass, radio communication, and geospatial web information which can provide a clue in using the situation aware services based on lab experiments and surveys. According to the result of lab experiment on accuracy of determining location / direction with smart phones, owing to inherent lack of indoor accuracy in determining position and direction, as well as errors in spatial data used as platform, it was found that devices were not provided with sufficiently accurate data when using the situation aware services indoors compared to outdoors. To enhance accuracy of determining indoor positions, there are several methods including location metering based on Wi-Fi, which had several problems compared with GPS used in outdoor environment. Thus, it was determined that more study would be necessary to solve these issues.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Performance Evaluation of Thermal Control Subsystem of EOS-D Ver.1.0 from In-orbit Telemetry Data (비행 데이터를 이용한 EOS-D Ver.1.0의 열제어계 성능 평가)

  • Chang, Jin-Soo;Kim, Jong-Un;Kang, Myung-Seok;Kim, Ee-Eul;Yang, Seung-Uk;An, Su-Mi
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.70-79
    • /
    • 2016
  • Satrec Initiative successfully developed a high-resolution electro-optical camera system, EOS-D Ver.1.0. EOS-D Ver.1.0 is the main payload of DubaiSat-2 and Deimos-2, which are developed based on the SI-300 platform of Satrec Initiative. After the launch and early operation (LEOP) of DubaiSat-2 and Deimos-2, we performed refocusing for the telescope of EOS-D Ver.1.0 to compensate for the dimensional change of its metering structure by moisture out-gassing. Before and after refocusing, we conducted the performance evaluation of thermal control system(TCS) for EOS-D Ver.1.0 using the in-orbit telemetry data. The evaluation showed EOS-D Ver.1.0 was under well-controlled thermal environment, which demonstrates TCS was designed and developed to meet all requirements.

Design of r-Sensor Protocol and Hardware Implementation for Intelligent Home Service (지능형 홈서비스를 위한r-Sensor프로토콜설계 및 하드웨어 구현)

  • Kwak, Tae-Kil;Lee, Bum-Sung;Jung, Jin-Wook;Jin, Kyo-Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.2113-2119
    • /
    • 2006
  • In this paper, we design the r-Sensor protocol for reliable data transmission in the Intelligent Home Service based on the wireless sensor network environment. The r-Sensor protocol improve the reliability of data transmission and node fairness using simple routing algorithm, congestion control, and loss recovery method that minimize the load of relay node. Reposed routing algorithm find out upstream and downstream nodes using the Network Management packet. Meanwhile, loss recovery algorithm uses the Aggregated-Nack. To apply supposed algorithm, the IHS-AMR(Intelligent Home Service - Automatic Meter Reader) and sensor node are designed and implemented in hardware. The IHS-AMR provides remote metering service and also offers home safety service by internetworking with sensor network, mobile phone network and internet.

Leakage detection and management in water distribution systems

  • Sangroula, Uchit;Gnawali, Kapil;Koo, KangMin;Han, KukHeon;Yum, KyungTaek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.160-160
    • /
    • 2019
  • Water is a limited source that needs to be properly managed and distributed to the ever-growing population of the world. Rapid urbanization and development have increased the overall water demand of the world drastically. However, there is loss of billions of liters of water every year due to leakages in water distribution systems. Such water loss means significant financial loss for the utilities as well. World bank estimates a loss of $14 billion annually from wasted water. To address these issues and for the development of efficient and reliable leakage management techniques, high efforts have been made by the researchers and engineers. Over the past decade, various techniques and technologies have been developed for leakage management and leak detection. These include ideas such as pressure management in water distribution networks, use of Advanced Metering Infrastructure, use of machine learning algorithms, etc. For leakage detection, techniques such as acoustic technique, and in recent yeats transient test-based techniques have become popular. Smart Water Grid uses two-way real time network monitoring by utilizing sensors and devices in the water distribution system. Hence, valuable real time data of the water distribution network can be collected. Best results and outcomes may be produced by proper utilization of the collected data in unison with advanced detection and management techniques. Long term reduction in Non Revenue Water can be achieved by detecting, localizing and repairing leakages as quickly and as efficiently as possible. However, there are still numerous challenges to be met and future research works to be conducted in this field.

  • PDF

AMI System Using Smart Electricity Meter Embedded with Home Concentrate Unit (세대집중화장치를 포함하는 스마트 전력량계를 이용한 AMI 시스템)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.537-546
    • /
    • 2019
  • In this paper, a system that integrates a home concentrate unit(HCU) in a smart electricity meter to collects water, gas, hot water, and heating usage required for AMI has been proposed. The collected data could be transmitted to the in house display(IHD) and server to provide a more economical AMI system. The developed system is less expensive in the network configuration than the existing system, which could reduce the operating cost, and be easy to install. By applying the developed system, the usage of electricity, water, gas, hot water and heating could be measured and these make it easier to apply AMI system. The main contents of the development are the smart electricity meter and embedding of HCU into the smart electricity meter, and transferring these data to IHD and server to structure the AMI system. The each developed unit has been networked to structure the AMI system to perform the actual meter reading operation and show the result.

A Study on the Application of Bridge Maintenance System using LoRa LPWAN Wireless Communication (LoRa LPWAN 무선 통신을 활용한 교량 유지관리 시스템 적용성 연구)

  • Park, Jin-o;Park, Sang-Heon;An, Sung-Ju;Park, Won-Joo;Kim, Jong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.138-146
    • /
    • 2019
  • LoRa LPWAN network system uses a license-exempt wireless communication system and implements data measurement through the integrated sensor based on Mems and wireless communication of existing measurement sensors. This system has superior technological / economic superiority using existing network and long distance communication compared to existing wireless measurement system, and secured economical efficiency by minimizing system construction equipment compared to wired measurement system. It is confirmed that the economical efficiency can be reduced by 41% compared to the conventional wired metering system. Since the LoRa LPWAN network system is excellent in terms of maintenance and operation, if installed in many bridges in Korea in the future, it will be developed as an excellent system in the maintenance of bridges. Etc.), and plant field (fire safety, etc.).

Smart meter data transmission device and power IT system using LTE and IoT technologies (LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템)

  • Kang, Ki-Beom;Kim, Hong-Su;Jwa, Jeong-Woo;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.117-124
    • /
    • 2017
  • A Smart Grid is a system that can efficiently use energy by exchanging real-time information in both directions between a consumer and a power supplier using ICT technology on an existing power network. DR(Demand response) is an arrangement in which electricity users can sell the electricity they save to the electricity market when the price of electricity is high or the power system is crisis. In this study, we developed a power meter data transmission device and power IT system that measure the demand information in real-time using a smart meter and transmit it to a cloud server. The power meter data transmission device developed in this study uses alight sensor connected to a Raspberry Pi 3 to measure the number of blinking lamps on the KEPCO meter per unit of power, in order to provide reliable data without any measurement errors with respect to the KEPCO power data. The power measurement data transmission device uses the standard communication protocol, OpenADR 2.0b. The measured data is transmitted to the power IT system, which consists of the VEN, VTN, and calculation program, via the LTE WiFi communication network and stored in its MySQL DB. The developed power measurement data transmission device issues a power supply instruction and performs a peak reduction DR when a power system crisis occurs. The developed power meter data transmission device has the advantage of allowing the user to adjust it every 1 minute, where as the existing smart metering time is fixed at once every 15 minutes.

End-use analysis of household water by metering (가정용수의 용도별 사용량 조사 및 원단위 분석)

  • Kim, Hwa-Soo;Lee, Doo-Jin;Kim, Ju-Whan;Kim, Jung-Hyun;Jung, Kwan-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.869-877
    • /
    • 2008
  • The purpose of this study is to investigate the trends and patterns of variou kind of water uses in a household by metering in Korea. Water use components are classified by toilet, washbowl, bathing, laundry, kitchen, etc. Flow meters are installed in 146 household selected by sampling in all around Korea. The data are gathered by web-based data collection system from the year 2002 to 2006, considering pre-investigated data such as occupation, revenue, family members, housing types, age, floor area, water saving devices, education, etc. Reliable data are selected by upper fence method for each observed water use component and statistical characteristics are estimated for each residential type to determine liter per capita per day. Estimated domestic per capita day show an indoor water use with the range from $150{\ell}pcd$ to $169{\ell}pcd$ for each housing type as the order of high rise apartment, multi-house, and single house. As the order of consuming amount among water use components, it is investigated that toilet($38.5{\ell}pcd$) is the first, and the second is laundry water($30.8{\ell}pcd$), the third is kitchen($28.4{\ell}pcd$), the fourth is bathtub($24.7{\ell}pcd$), the next is washbowl($15.4{\ell}pcd$). The results are compared with water uses in U.K. and U.S. As life style has been changed into western style, pattern of water use in Korea is tend to be similar with the U.S. water use pattern. Compared with the surveying results by Bradley, on 1985. Thirty liter of total use increased with the advancement of economic level, and a little change of water use pattern can be found. Especially, toilet water take almost half part of total water use and laundry water shows lowest as 11% in surveying at the year of 1985. But, this study shows that 39 liter, 28% of toilet water, has been decreased by the spread of saving devices and campaign. It is supposed that the spread large sized laundry machine make by-hand laundry has been decreased and water use increased. Unit water amount of each end-use in household can be applied to design factor for water and wastewater facilities, and it play a role as information in establishing water demand forecasting and conservation policy.

  • PDF

End-use Analysis of Household Water by Metering (가정용수의 용도별 사용 원단위 분석)

  • Kim, Hwa Soo;Lee, Doo Jin;Kim, Ju Whan;Jung, Kwan Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.595-601
    • /
    • 2008
  • The purpose of this study is to investigate the trends and patterns of various kind of water uses in a household by metering in Korea. Water use components are classified by toilet, washbowl, bathing, laundry, kitchen, miscellaneous. Flow meters are installed in 140 household selected by sampling in all around Korea. The data are gathered by web-based data collection system from the year 2002 to 2006, considering pre-investigated data such as occupation, revenue, family members, housing types, age, floor area, water saving devices, education, miscellaneous. Reliable data are selected by upper fence method for each observed water use component and statistical characteristics are estimated for each residential type to determine liter per capita per day. Estimated domestic per capita day show an indoor water use with the range from 150 lpcd to 169 lpcd for each housing type as the order of high rise apartment, multi-house, and single house. As the order of consuming amount among water use components, it is investigated that toilet (38.5 lpcd) is the first, and the second is laundry water (30.8 lpcd), the third is kitchen (28.4 lpcd), the fourth is bathtub (24.7 lpcd), the next is washbowl (15.4 lpcd). The results are compared with water uses in U.K. and U.S. As life style has been changed into western style, pattern of water use in Korea is tend to be similar with the U.S. water use pattern. Compared with the surveying results by Bradley, on 1985. Thirty liter of total use increased with the advancement of economic level, and a little change of water use pattern can be found. Especially, toilet water take almost half part of total water use and laundry water shows lowest as 11% in surveying at the year of 1985. But, this study shows that 39 liter, 28% of toilet water, has been decreased by the spread of saving devices and campaign. It is supposed that the spread large sized laundry machine make by-hand laundry has been decreased and water use increased. Unit water amount of each end-use in household can be applied to design factor for water and wastewater facilities, and it play a role as information in establishing water demand forecasting and conservation policy.