• 제목/요약/키워드: Meter valve

검색결과 84건 처리시간 0.027초

릴리프밸브 쿠션기구 내장형 공기압 실린더의 구동 특성 (Driving Characteristics of Pneumatic Cylinder with Relief Valve Cushion Devices)

  • 김도태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권4호
    • /
    • pp.7-13
    • /
    • 2016
  • This paper presents the meter-out and meter-in speed control characteristics of a pneumatic cylinder with relief valve type cushion device. The piston displacement and velocity are measured to investigate high speed driving performance with variation of the pressure setting in relief valve, air supply pressure, load mass, the supply and exhaust flow rate from the cylinder. Also, the internal pressures and temperatures driving pressure and cushion chamber are measured. The piston displacements and velocities of meter-out and meter-in control are compared experimentally determined data. A comparison experimental data meter-out and meter-in control show that a relief valve type cushion device is suitable for high speed pneumatic cylinders. The desired response characteristics of piston displacement and velocity are satisfactory adjust the pressure setting of a relief valve with varying system parameters such as air supply pressure, load mass and controlled flow rate.

밸브 수압측정기의 유동해석 (Computational Fluid Dynamics of Hydraulic Valve Meter)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.1963-1968
    • /
    • 2012
  • 본 논문은 현장에서 사용하고 있는 밸브 수압측정기를 3차원 자동설계 프로그램인 CATiA를 활용하여 설계하였다. 또한 유한요소 해석코드인 ANSYS를 활용하여 설계된 밸브 수압측정기에 대하여 유동해석을 수행하여 내부압력에 따른 유체의 흐름을 구하였다. 이러한 해석결과는 새로운 밸브 수압측정기를 개발하는데 기초자료로 활용될 계획이며 개발예정인 밸브 수압측정기는 밸브 점검 시 시간을 단축하고, 사고를 방지하여 안전성을 향상시킨다.

밸브 수압측정기의 구조해석 (Structural Analysis of Hydraulic Valve Meter)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1447-1452
    • /
    • 2012
  • 산업현장에서 사용되고 있는 기존의 밸브 수압측정기는 압력조절을 수동으로 제어함으로서 정확한 압력측정을 할 수 없는 불편함이 있었다. 이를 개선하기 위하여 기존의 밸브 수압측정기에 대하여 자동설계 프로그램인 CATIA를 활용하여 설계하고 3차원 유한요소 해석코드인 ANSYS를 활용하여 설계된 밸브 수압측정기에 대하여 구조해석을 수행하고 내부압력에 따른 내부누수, 응력, 변형률, 총변형량 등을 구하였다. 이러한 결과는 새로운 밸브 수압측정기를 개발하기 위한 기초자료로 활용할 계획이다.

공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구 (A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders)

  • 김도태
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.

공압회로에서 미터인 회로와 미터아웃 회로의 특성 비교 (Characterics of Meter-In / Meter-Out Circuits to pneumatic System)

  • 박재범;염만오
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.446-450
    • /
    • 2002
  • Pneumatic system has been mainly used as main equipment for actuation and control of compressed air force in manufacturing industry, pneumatic circuit for the most part is used in Meter-Out circuit. Meter-Out circuit method is Flow Control Valve to fit in exhaust part of cylinder port. In the reverse, Meter-In circuit is Flow Control Valve to fit in input part of cylinder port. This study examines the dynamic characteristics comparison of Meter-In and Meter-Out Circuits in the pneumatic circuits. The results of the experimental research are obtained to the followings: i ) System Response is Meter-In Circuit more than Meter-Out one before cushion zone. ii) we conjectured that the collision of piston and head cover is ease to collide Meter-In Circuit more than Meter-Out one at the stroke end part.

  • PDF

Sensitivity of Hot Film Flow Meter in Four Stroke Gasoline Engine

  • Lee, Gangyoung;Lee, Cha--Myung;Park, Simsoo;Youngjin Cho
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.286-293
    • /
    • 2004
  • The air fuel ratios of current gasoline engines are almost controlled by several air flow meters. When CVVT (Continuous Variable Valve Timing) is applied to a gasoline engine for higher engine performance, the MAP (Manifold Absolute Pressure) sensor is difficult to follow the instantaneous air fuel ratio due to the valve timing effect. Therefore, a HFM (Hot Film Flow Meter) is widely used for measuring intake air flow in this case. However, the HFMs are incapable of indicating to reverse flow, the oscillation of intake air flow has an negative effect on the precision of the HFM. Consequently, the various duct configurations in front of the air flow sensor affect the precision of HFM sensitivity. This paper mainly focused on the analysis of the reverse flow, flow fluctuation in throttle upstream and the geometry of intake system which influence the HFM measurement.

MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구 (A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC)

  • 이승희;이민철;고석조;장용석;최문호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구 (An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve)

  • 오철;문성배;손용길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

유압 블리드-오프 회로의 특성 재검토 및 실험적 동특성 모델링 (Reexamination and Derivation of Empirical Dynamic Model for a Hydraulic Bleed-Off Circuit)

  • 정헌술;이광헌;김형의
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1552-1564
    • /
    • 2002
  • Meter-in, meter-out and bleed-off circuits are widely utilized in order to adjust the speed of a hydraulic actuator by using a flow control valve and in order to regulate the pressure of a hydraulic volume by using a simple on-off valve. In these circuits, a relief valve serves either to maintain constant system pressure or to protect the system from over-pressure loading. The relief valve of a bleed-off circuit is the second case frequently undergoing on-off action during operation. It makes the analysis of the pressure control characteristics of the circuit highly difficult. In this paper, steady-state flow rate, pressure, heat loss and efficiency of the three circuits are reexamined and basic experiments far obtaining the characteristics of a pump and relief valve are conducted. Finally, simple empirical first-order dynamic models of decreasing and increasing pressure were separately proposed and verified by comparison with experiment. As the result, the basis for the theoretical analysis of the pressure control characteristics of a bleed-off circuit using a simple on-off valve is established.